Carrier Access 770-0125-AB installation manual Module Red LED Module Green LED Status Top Bottom

Models: 770-0125-AB

1 96
Download 96 pages 9.24 Kb
Page 30
Image 30

Installation

Installing the NSP101 Control Card

To install the NSP101, open the ejector tabs and slide the card into its proper slot until you feel resistance, then push to close the ejector tabs into their locking position against the metal rails. Verify that the card is firmly placed by applying pressure to the ejector tabs to seat the card fully in the chassis.

WARNING! WHEN INSTALLING OR REPLACING BROADWAY HARDWARE, ALWAYS ADHERE TO GOOD PRACTICE WITH RESPECT TO ESD PROCEDURESUSE A REGULARLY AND PROPERLY TESTED GROUNDING STRAP.

Each NSP101 has eight front panel LED indicators. From left to right, the two rows of indicators on each NSP101 indicate NSP101 module operating status (common indicators to all control and line interface cards), active card, power input status and Ethernet line activity.

NIP-1

 

E

 

L

 

U

 

D

M

O

 

13

INTERFACE

NIP-5

NSP-2

NSP-1

E

1

3

 

 

 

INTERFACE

 

 

 

 

 

 

2

 

 

 

 

1

 

ACTIVE

ALARM SUM

PWR

2

ETH

 

 

 

1

 

UIP-2

ACTIVE

 

 

 

UIP-1

 

 

 

 

1

3

5

7

9 11 13 15

OSP-1

BSP-4

BSP-3

BSP-2

BSP-1

E

C E

A D w a y

TM

The following tables describe the status of the NSP101 control card based upon the front panel LED status of the card.

MODULE Red LED

MODULE Green LED

Status

(Top)

(Bottom)

 

 

 

 

Off

Off

No power to the card

 

 

 

Off

On

Card operating normally

 

 

 

On

Off

Card failure

 

 

 

On

On

Card initializing during system

 

 

power up

 

 

 

Active or standby NSP101:

ACTIVE Green LED

Status

 

 

On

This is the Active NSP101

 

 

Blinking Slow

This is the Standby NSP101

 

 

Blinking Fast

The NSP101s are synchronizing databases

 

 

CAUTION! WHEN BROADWAY DATABASES ARE SYNCHRONIZING BETWEEN THE ACTIVE AND STANDBY BROADWAY SYSTEMS, THE ACTIVE LEDS ON THE NSP101S BLINK RAPIDLY

TO SIGNIFY A FILE TRANSFER IS IN PROGRESS. YOU MUST WAIT UNTIL THESE LEDS HAVE STOPPED FLASHING BEFORE YOU PERFORM ANY OPERATION TO RE-INITIALIZE THE BROADWAY SYSTEM EITHER THROUGH A REBOOT OR FORCED NSP101 PROTECTION SWITCHOVER.

2-14

BROADway - Release 4.00

Page 30
Image 30
Carrier Access 770-0125-AB installation manual Module Red LED Module Green LED Status Top Bottom, Active Green LED Status