Configuration

Management Access to the BROADway System

Management Access to the BROADway System

To further configure the BROADway system, you can access the unit through:

!A local connection to the serial port SCP-1using a command line interface

!A remote modem connection to the serial port SCP-1using a command line interface

!Either Ethernet interface ETH-1or ETH-2using Telnet and a command line interface

!Either Ethernet interface ETH-1or ETH-2using a web browser GUI interface

Viewing Serial Craft Port Settings With the GUI

To view the configuration of the Serial Craft Port (SCP):

1.In the navigation tree, select either the SCP-1or SCP-2interface on an NSP card.

2.In the menu bar, click Config, then Interface.

3.Use the SCP-1 RS232 Configuration window to view the parameters for the SCP port. These fields are fixed and cannot be edited.

4.Click Close to close this window.

Local SCP-1 Serial Craft Port

Access

1.Connect to the SCP-1port directly and open a VT100 terminal emulation program. (For cabling information, see Cabling the Serial Craft Port on page 2-9.)

2.Press ENTER, and you should see the NSP1> or NSP2> prompt. Follow the instructions on page 3-13to log into the system.

Remote Modem SCP-1 Serial Craft Port Access

1.Connect a modem to the SCP-1directly using a modem cable and configure the modem appropriately. Follow the modem manufacturers instructions to set the modem for connection via RS232 at 9600bps, 8 data bits, no parity and one stop bit at the DTE port. The modem should be set to auto-answer incoming calls and local echo options should be disabled.

NOTE: It is particularly important to ensure that all local CONNECT messages and terminal echo options are disabled on the modem as these messages arriving at the BROADway system from a modem port can be interpreted as command line interface strings.

2.Dial in to the modem using a VT100 terminal emulation program and, once the modem has trained and answered you should be presented with the NSP1> or NSP2> prompt. Follow the instructions on page 3-13to log into the system.

BROADway - Release 4.00

3-7

Page 55
Image 55
Carrier Access 770-0125-AB Management Access to the BROADway System, Viewing Serial Craft Port Settings With the GUI