Home Automation SECURITY SYSTEM owner manual Control, About UPB

Page 18

CONTROL

The control features of the OmniLT make it easy and convenient to control almost any light or appliance from the console or over the telephone. You may also have your heating and air conditioning (HVAC) under control of the system, which will allow you to save energy dollars by setting the temperature appropriately when you are home, asleep, or away.

Furthermore, the OmniLT can be used to program lights to make your home look occupied as a deterrent to potential thieves.

The methods that the OmniLT uses to control different things are:

UPB switches, modules, and keypads for lights and appliances

CentraLite loads and relays on a LiteJet and Elegance lighting system

RadioRA switches and dimmers on a Lutron RadioRA lighting system

ALC switch modules for lights and appliances

X-10, X-10 Pro, Leviton, PCS, ACT, Lightolier, and compatible modules for lights and small appliances.

HAI Communicating Thermostats for controlling Heating, Ventilation, and Air Conditioning Systems.

Programmable Energy Saver Modules (PESM) for central heating and air conditioning systems.

Direct Relay Control for sprinklers, lighting, electric heating, etc.

An OmniLT will control:

¾16 UPB switches, modules, and keypads (2 rooms of HLC Lighting)

¾16 CentraLite loads and relays

¾16 RadioRA switches and dimmers

¾16 ALC switch modules

¾16 X-10 modules (one house code)

¾2 PESMs or Voltage Outputs (expandable to 10)

¾2 HAI Communicating Thermostats

OmniLT also has 8 internal "flags" that are used for programming conditionals and running buttons.

About UPB

UPB is a powerline communications standard for lighting and home control. UPB is a robust, two-way digital powerline carrier communications protocol which transmits signals over the existing wires in a home. UPB can coexist peacefully with X-10 systems, intercoms, baby monitors, speakers, etc. that communicate over the powerline.

Using a Powerline Interface Module (PIM), OmniLT sends UPB commands over the existing electrical wiring to special switches, modules, and keypad controllers (UPB devices) that are designed with UPB technology. UPB switches are two-way devices, so OmniLT knows the actual status of the switch when it is controlled locally. In addition, UPB switches, modules, and keypads can be used to trigger macros in the OmniLT controller.

14

Image 18
Contents Document Number 21R00-1Rev. January Document Number 21R00-1Rev. January Copyright 2000-2006HAI All Rights ReservedCONTROL OVERALL DESCRIPTIONSECURITY SYSTEM OPERATION ContentsSETUP TELEPHONE CONTROLINTRODUCTION Underwriters Laboratories UL Listing1- OFF OVERALL DESCRIPTIONConsole Operation 2- DAY6- UP ARROW Normal Top-LevelDisplayDisplay Menus 7- CONSOLE LEDTrouble Beeps Error BeepsMain Menu To silence the beeper, press the * keyConfirmation Beep OmniLT MaintenanceCancel Time Out0 = OFF SECURITY SYSTEM OPERATIONArming the Security System 1 = DAY3 = AWAY Using Shortcut Keys2 = NIGHT 4 = VACATIONBypassing Zones 9 = RESTOREQuick Arm Restoring ZonesWhat To Do When You Come Home What Happens When the Alarm is ActivatedBurglar Alarm Activated Emergency Keys Fire Alarm ActivatedGas Alarm Activated OMNIAlarm Cancel Duress Code Entered or Duress Alarm ActivatedAlarm Reset Police EmergencyTrouble Indications CodesMaster Code Manager Code Panic SwitchesTesting Your System User CodeCONTROL About UPBHAI Lighting Control HLC Format When set to UPB, the OmniLT controller canRoom Controller LED Indicators About RoomsAbout House Controllers When set to CentraLite, the OmniLT controller canAbout Lutron RadioRA About CentraLiteAbout When set to RadioRA, the OmniLT controller canAbout ALC House CodeControlling Units Configuring Lighting Scenes in an HLC RoomScrolling Through Names Controlling a Room of HLC LightingStep OperationControlling CentraLite Units Controlling RadioRA Units Controlling ALC or X-10UnitsScene Command Compose Timed CommandsRamp Command ALC Controlling Compose UnitsStatus of a Unit Internal FlagsControlling Outputs All On / Off All Lights OnAll Off Scene On Command Scene CommandsScene Set Command Leviton Scene ControlUPB Links Scene Off CommandSetting a Link Lighting Scenes Activating and Deactivating LinksExecuting CentraLite Scenes ButtonsExecuting Phantom Buttons Leave for Work ButtonTemperature Control HAI RC-SeriesThermostatsDinner for Two Button For HAI heat/cool thermostats Programmable Energy Saver Modules PESMs Control actions for temperature sensors Indoor and Outdoor Temperature Freeze AlarmsIMPORTANT NOTES Upstairs 2=LOW 3=HIGH #=STATStatus Temperature AlarmsHumidity Temperature Control of AppliancesConfiguring HLC Devices Configuring HLC Devices using an Omni ConsoleStep Operation Setup Mode for HLC DevicesStep Operation Step OperationRING - RINGING ONHK - ON HOOKOFFHK - OFF HOOK DEAD - DEAD PHONE LINEEvent Log Show EventsMessages Show MessageLog Message Phone Message Clear MessageSay Message Send Message Pro-LinkPro-Linkalso has the capability to monitor the serial port for incoming text messages. When a text message is received, Pro-Linksearches through all 16 messages for a matching message. If one is found, the Program Command macro corresponding to the matching message is activated In-HousePhones TELEPHONE CONTROLTelephone Interface Remote PhonesPhone Access Denied - Remote Lockout Alternate MethodMain Menu Panic Button over the Phone # # # # # # PC AccessWhen a Two-WayAudio Module is being used Recording Your AddressVoice Dialer Emergency Dial-OutDigital Dialer How the OmniLT Voice Dialer WorksWhat You Hear - If Your OmniLT Calls You Entering the Code1 = Master SETUPSet Up Codes 2 = ManagerTIME Set Up TimeSet Up Programs Duress Code1 = Add Programs 2 = Show Programs3 = Delete All Programs Edit Programs Edit Programs WhenTimes Programs Control Unit / Switch Press Event Buttons Button and Event ProgramsOmniLT Corresponding Switch TableSwitch UPB 6-ButtonKeypadZone Event Buttons All On/Off Event ButtonsAlarm Event Buttons UPB Link TriggersX-10Event Buttons Miscellaneous Event Buttons Message Event Buttons Pro-LinkEdit Program Command Switch Press Event Buttons CentraLiteProgram Control Commands Program Button Commands Unit Toggle CommandProgram Security Commands WHEN LINK 1 ON Porch Light STATUSProgram Message Commands Program All On / All Off CommandsProgram Video Commands Edit Program ConditionProgram Time Clock Conditions Program Security Mode ConditionsProgram Zone Conditions Program Other ConditionsSet Up Dial Telephone AccessAnswer Outside Call Dial Type Remote CommandsRings Before Answer My Phone NumberDial Order Set Up ArmingDial Out Numbers Entry DelayAll On For Alarm Enable Quick ArmEnable Auto Bypass Exit DelayEnable Freeze Alarm Set up MiscellaneousAnnounce Alarms Flash For AlarmDESCRIPTION FORMATNUMBER House Code All OffLatitude, Longitude, and Time Zone ZONE NAMENUMBER Set Up NamesDaylight Savings DESCRIPTIONSet Up Voice Set Up Address UNDERWRITERS LABORATORIES REQUIREMENTS FIRE ESCAPE PLANNINGFEDERAL COMMUNICATION COMMISSION NOTICE HAI 21487 Bayou Ct Abita Springs, LACANADIAN INDUSTRY CANADA NOTICE UL RATINGS APPENDIX A - SPECIFICATIONSCONTROLLER OUTPUTS MAXIMUMCODE CHAR APPENDIX B - CHARACTER CODESCODE CHAR CODE CHARDESCRIPTION APPENDIX C - VOICE DESCRIPTIONSCODE CODECODE CODEDESCRIPTION DESCRIPTIONCODE DESCRIPTION CODE DESCRIPTIONPage NOTE TO INSTALLER HAI New Orleans, LA U S A