To set up your thermostat for use with the energy saver, set it in the appropriate mode and set the temperature to your preference.
NOTE: Your heating and cooling system will always be off if you set your thermostat to Off mode. The PESM cannot turn it back on. The PESM cannot make your system cool below the thermostat's cool setting, or heat above the thermostat's heat setting.
Control actions for temperature sensors:
•Set low setpoint
•Set high setpoint
To enter the temperature menu, from the
TEMPERATURE ZONE:
ENTER TEMPERATURE ZONE ↓
After the ' # ' key is pressed, a menu appropriate for the type of temperature zone is shown.
For Programmable Energy Saver Modules: |
| |
Upstairs |
| 2=HEAT ↓ |
0=OFF | 1=ON | |
Upstairs |
| #=STAT ↑ |
3=COOL | 4=TIME | |
For temperature sensors: |
|
|
Upstairs |
|
|
2=LOW | 3=HIGH | #=STAT |
To set a temperature setpoint, press 2 (HEAT) or 3 (COOL).
For Celsius temperatures, press the ' # ' key prior to entering the temperature to make the number negative. The Celsius temperature may also be specified in 0.5 degree steps if three numeric digits are entered. The third digit adds a .5 to the first two digits if it is any- thing other than zero. Enter a leading zero if necessary.
In additions to setpoint changes, an energy saver may be turned On or Off. It may also be turned On or Off for a specific duration.
To turn the energy saver Off, select 0 (OFF). To turn the energy saver On, select 1 (ON). To turn the energy saver On or Off for a specific duration, select 9 (TIME) prior to selecting On or Off. Enter the time as described under Control - Unit Commands.
Downstairs | 2=HEAT ↓ | |
0=OFF | 1=ON | |
Downstairs | #=STAT ↑ | |
3=COOL | 9=TIME | |
ENTER TIME |
| |
MINUTES | #=H/M/S | |
Downstairs | FOR 15M | |
0=OFF | 1=ON | ↓ |
The current status of a temperature zone may be displayed by selecting ' # ' (STAT) key from the main temperature menu. The status display differs depending on the temperature zone type.
When you are finished, press the ' * ' key twice to return to the