The OmniLT has 2 (expandable to 10) outputs that can be used to switch relays. Outputs 1 and 2 are controlled by unit numbers 27 and 28. These are hardwired outputs that are connected directly through the OmniLT and not through a module. If you have something connected to these outputs, such as a sprinkler system, your dealer will explain its operation.

Outputs cannot be brightened or dimmed.

Outputs are not affected by All ON or All Off commands.

All On / Off

The All On/Off menu is used to turn all lighting unit numbers on and off.

Note: UPB, CentraLite, and RadioRA devices are not affected by the OmniLT “All On” or “All Off” command. To achieve this functionality, we suggest the following:

UPB: Program a Link into each device that will respond to an OmniLT “All On” and “All Off” command program. For example:

In each UPB switch that will respond to “All Off” and “All On”, program a Link (in this example, Link 50 is used) that will go to 100% when activated (turned on). Then write the following programs in the OmniLT controller:

WHEN ALL ON: LINK 50 ON

WHEN ALL OFF: LINK 50 OFF

CentraLite: Program the “All On” and “All Off” macro to execute an All On Scene and an All Off Scene on the CentraLite.

RadioRA: Program the “All On” and “All Off” macro to execute Phantom Button 16 (All On) and Phantom button 17 (All Off).

For example:

WHEN ALL ON: PHANTOM BUTTON 16 ON

WHEN ALL OFF: PHANTOM BUTTON 17 ON

This All On/Off menu is also used to control Leviton Scenes, RadioRA Phantom Buttons, UPB Links, and CentraLite Scenes.

From the top-level display or from the main menu, press the 4 (ALL) key on the console keypad.

ALL

0=OFF 1=ON 2=SCN 3=LINK

ALL

4=PHANTOM 5=CENLIT

All Lights On

At the ALL prompt, press the 1 (LIGHTS ON) key. The console will beep, and a command will be sent that turns on all specified X-10 or ALC units or HLC Rooms. X-10 Appliance Modules do not respond when the All Lights On command is sent. By factory default, all lighting units respond to the All-On command.

NOTE: The All On function can be changed, if desired - See Set Up Misc, All On And All Off.

All Off

At the ALL prompt, press the 0 (OFF) key. The console will beep, and a command will be sent that turns off all specified X-10 and ALC units and HLC Rooms. By factory default, all lighting units respond to the All-Off command.

NOTE: The All Off function can be changed, if desired - See Set Up Misc, All On And All Off.

23

Image 27
Contents Document Number 21R00-1Rev. January Copyright 2000-2006HAI All Rights Reserved Document Number 21R00-1Rev. JanuaryContents OVERALL DESCRIPTIONSECURITY SYSTEM OPERATION CONTROLTELEPHONE CONTROL SETUPUnderwriters Laboratories UL Listing INTRODUCTION2- DAY OVERALL DESCRIPTIONConsole Operation 1- OFF7- CONSOLE LED Normal Top-LevelDisplayDisplay Menus 6- UP ARROWTo silence the beeper, press the * key Error BeepsMain Menu Trouble BeepsTime Out OmniLT MaintenanceCancel Confirmation Beep1 = DAY SECURITY SYSTEM OPERATIONArming the Security System 0 = OFF4 = VACATION Using Shortcut Keys2 = NIGHT 3 = AWAYRestoring Zones 9 = RESTOREQuick Arm Bypassing ZonesWhat To Do When You Come Home What Happens When the Alarm is ActivatedBurglar Alarm Activated OMNI Fire Alarm ActivatedGas Alarm Activated Emergency KeysPolice Emergency Duress Code Entered or Duress Alarm ActivatedAlarm Reset Alarm CancelTrouble Indications CodesMaster Code User Code Panic SwitchesTesting Your System Manager CodeAbout UPB CONTROLAbout Rooms When set to UPB, the OmniLT controller canRoom Controller LED Indicators HAI Lighting Control HLC FormatAbout CentraLite When set to CentraLite, the OmniLT controller canAbout Lutron RadioRA About House ControllersHouse Code When set to RadioRA, the OmniLT controller canAbout ALC AboutControlling a Room of HLC Lighting Configuring Lighting Scenes in an HLC RoomScrolling Through Names Controlling UnitsStep OperationControlling CentraLite Units Controlling ALC or X-10Units Controlling RadioRA UnitsControlling Compose Units Timed CommandsRamp Command ALC Scene Command ComposeStatus of a Unit Internal FlagsControlling Outputs All On / Off All Lights OnAll Off Leviton Scene Control Scene CommandsScene Set Command Scene On CommandActivating and Deactivating Links Scene Off CommandSetting a Link Lighting Scenes UPB LinksLeave for Work Button ButtonsExecuting Phantom Buttons Executing CentraLite ScenesTemperature Control HAI RC-SeriesThermostatsDinner for Two Button For HAI heat/cool thermostats Programmable Energy Saver Modules PESMs Control actions for temperature sensors Upstairs 2=LOW 3=HIGH #=STAT Freeze AlarmsIMPORTANT NOTES Indoor and Outdoor TemperatureTemperature Control of Appliances Temperature AlarmsHumidity StatusConfiguring HLC Devices using an Omni Console Configuring HLC DevicesStep Operation Setup Mode for HLC DevicesStep Operation Step OperationDEAD - DEAD PHONE LINE ONHK - ON HOOKOFFHK - OFF HOOK RING - RINGINGShow Events Event LogMessages Show MessageLog Message Send Message Pro-Link Clear MessageSay Message Phone MessagePro-Linkalso has the capability to monitor the serial port for incoming text messages. When a text message is received, Pro-Linksearches through all 16 messages for a matching message. If one is found, the Program Command macro corresponding to the matching message is activated Remote Phones TELEPHONE CONTROLTelephone Interface In-HousePhonesPhone Access Denied - Remote Lockout Alternate MethodMain Menu Recording Your Address PC AccessWhen a Two-WayAudio Module is being used Panic Button over the Phone # # # # # #How the OmniLT Voice Dialer Works Emergency Dial-OutDigital Dialer Voice DialerEntering the Code What You Hear - If Your OmniLT Calls You2 = Manager SETUPSet Up Codes 1 = MasterDuress Code Set Up TimeSet Up Programs TIME2 = Show Programs 1 = Add Programs3 = Delete All Programs Edit Programs Edit Programs WhenTimes Programs Button and Event Programs Control Unit / Switch Press Event ButtonsUPB 6-ButtonKeypad Corresponding Switch TableSwitch OmniLTAll On/Off Event Buttons Zone Event ButtonsAlarm Event Buttons UPB Link TriggersX-10Event Buttons Message Event Buttons Pro-Link Miscellaneous Event ButtonsEdit Program Command Switch Press Event Buttons CentraLiteProgram Control Commands WHEN LINK 1 ON Porch Light STATUS Unit Toggle CommandProgram Security Commands Program Button CommandsEdit Program Condition Program All On / All Off CommandsProgram Video Commands Program Message CommandsProgram Other Conditions Program Security Mode ConditionsProgram Zone Conditions Program Time Clock ConditionsSet Up Dial Telephone AccessAnswer Outside Call My Phone Number Remote CommandsRings Before Answer Dial TypeEntry Delay Set Up ArmingDial Out Numbers Dial OrderExit Delay Enable Quick ArmEnable Auto Bypass All On For AlarmFlash For Alarm Set up MiscellaneousAnnounce Alarms Enable Freeze AlarmHouse Code All Off FORMATNUMBER DESCRIPTIONZONE NAME Latitude, Longitude, and Time ZoneDESCRIPTION Set Up NamesDaylight Savings NUMBERSet Up Voice Set Up Address FIRE ESCAPE PLANNING UNDERWRITERS LABORATORIES REQUIREMENTSHAI 21487 Bayou Ct Abita Springs, LA FEDERAL COMMUNICATION COMMISSION NOTICECANADIAN INDUSTRY CANADA NOTICE MAXIMUM APPENDIX A - SPECIFICATIONSCONTROLLER OUTPUTS UL RATINGSCODE CHAR APPENDIX B - CHARACTER CODESCODE CHAR CODE CHARCODE APPENDIX C - VOICE DESCRIPTIONSCODE DESCRIPTIONDESCRIPTION CODEDESCRIPTION CODECODE DESCRIPTION CODE DESCRIPTIONPage HAI New Orleans, LA U S A NOTE TO INSTALLER