Home Automation SECURITY SYSTEM Format, Number, Description, House Code All Off, Time Clocks

Page 68

FORMAT

NUMBER

DESCRIPTION

STANDARD

0

Preset Dim Command (X-10, X-10 Pro, Leviton, PCS, etc.)

EXTENDED

1

Extended Code Level Command (Leviton)

COMPOSE

2

Compose Mode (Lightolier's Compose)

UPB

3

Universal Powerline Bus (open format)

RADIO RA

4

Lutron RadioRA

HAI LIGHTING

5

HAI Lighting Control (HLC)

CENTRALITE

6

CentraLite Lighting

The default setting for HC 1 Format is 5 (HLC).

House Code All Off

This feature allows you to choose if the House Code will respond to the “All Off” command. Press the 0 key to select No and the 1 key to select Yes.

HC 1

ALL OFF:

1

0=NO

1=YES

 

The default setting for HC 1 All Off is Yes.

Notes:

1.When configured, the House Code will affect 2 rooms of HLC lighting (i.e. HC 1 ALL OFF affects Room 1 and 2).

2.When the House Code is configured as UPB, RadioRA, or CentraLite, “House Code All Off” does not affect the state of the installed devices; however, if this setup item is set to “Yes”, OmniLT will change the status of all units on that House Code to “Off” (even though it doesn’t explicitly send an All Off command to those units). If the “House Code All Off” setup item is set to “No”, OmniLT will not change the status of units on that House Code.

House Codes All On

This feature allows you to choose if the House Code will respond to the “All On” command. Press the 0 key to select No and the 1 key to select Yes.

HC 1

ALL ON:

1

0=NO

1=YES

 

The default setting for HC 1 All On is Yes.

Notes:

1.When configured, the House Code will affect 2 rooms of HLC lighting (i.e. HC 1 ALL ON affects Room 1 and 2).

2.When the House Code is configured as UPB, RadioRA, or CentraLite, “House Code All On” does not affect the state of the installed devices; however, if this setup item is set to “Yes”, OmniLT will change the status of all units on that House Code to “On” (even though it doesn’t explicitly send an All On command to those units). If the “House Code All On” setup item is set to “No”, OmniLT will not change the status of units on that House Code.

Time Clocks

There are three time clocks in the system are used to conditionalize programs. They are used solely to define time periods during the week when certain programs should be enabled or disabled to execute.

TIME CLOCK 1 ON

TIME CLOCK 1 OFF

Specify the On and Off times for each Time Clock - See Set Up Codes.

TIME CLOCK 1 ON TIME:

64

Image 68
Contents Document Number 21R00-1Rev. January Document Number 21R00-1Rev. January Copyright 2000-2006HAI All Rights ReservedOVERALL DESCRIPTION SECURITY SYSTEM OPERATIONCONTROL ContentsSETUP TELEPHONE CONTROLINTRODUCTION Underwriters Laboratories UL ListingOVERALL DESCRIPTION Console Operation1- OFF 2- DAYNormal Top-LevelDisplay Display Menus6- UP ARROW 7- CONSOLE LEDError Beeps Main MenuTrouble Beeps To silence the beeper, press the * keyOmniLT Maintenance CancelConfirmation Beep Time OutSECURITY SYSTEM OPERATION Arming the Security System0 = OFF 1 = DAYUsing Shortcut Keys 2 = NIGHT3 = AWAY 4 = VACATION9 = RESTORE Quick ArmBypassing Zones Restoring ZonesBurglar Alarm Activated What To Do When You Come HomeWhat Happens When the Alarm is Activated Fire Alarm Activated Gas Alarm ActivatedEmergency Keys OMNIDuress Code Entered or Duress Alarm Activated Alarm ResetAlarm Cancel Police EmergencyMaster Code Trouble IndicationsCodes Panic Switches Testing Your SystemManager Code User CodeCONTROL About UPBWhen set to UPB, the OmniLT controller can Room Controller LED IndicatorsHAI Lighting Control HLC Format About RoomsWhen set to CentraLite, the OmniLT controller can About Lutron RadioRAAbout House Controllers About CentraLiteWhen set to RadioRA, the OmniLT controller can About ALCAbout House CodeConfiguring Lighting Scenes in an HLC Room Scrolling Through NamesControlling Units Controlling a Room of HLC LightingControlling CentraLite Units StepOperation Controlling RadioRA Units Controlling ALC or X-10UnitsTimed Commands Ramp Command ALCScene Command Compose Controlling Compose UnitsControlling Outputs Status of a UnitInternal Flags All Off All On / OffAll Lights On Scene Commands Scene Set CommandScene On Command Leviton Scene ControlScene Off Command Setting a Link Lighting ScenesUPB Links Activating and Deactivating LinksButtons Executing Phantom ButtonsExecuting CentraLite Scenes Leave for Work ButtonDinner for Two Button Temperature ControlHAI RC-SeriesThermostats For HAI heat/cool thermostats Programmable Energy Saver Modules PESMs Control actions for temperature sensors Freeze Alarms IMPORTANT NOTESIndoor and Outdoor Temperature Upstairs 2=LOW 3=HIGH #=STATTemperature Alarms HumidityStatus Temperature Control of AppliancesConfiguring HLC Devices Configuring HLC Devices using an Omni ConsoleSetup Mode for HLC Devices Step OperationStep Operation Step OperationONHK - ON HOOK OFFHK - OFF HOOKRING - RINGING DEAD - DEAD PHONE LINEEvent Log Show EventsLog Message MessagesShow Message Clear Message Say MessagePhone Message Send Message Pro-LinkPro-Linkalso has the capability to monitor the serial port for incoming text messages. When a text message is received, Pro-Linksearches through all 16 messages for a matching message. If one is found, the Program Command macro corresponding to the matching message is activated TELEPHONE CONTROL Telephone InterfaceIn-HousePhones Remote PhonesMain Menu Phone Access Denied - Remote LockoutAlternate Method PC Access When a Two-WayAudio Module is being usedPanic Button over the Phone # # # # # # Recording Your AddressEmergency Dial-Out Digital DialerVoice Dialer How the OmniLT Voice Dialer WorksWhat You Hear - If Your OmniLT Calls You Entering the CodeSETUP Set Up Codes1 = Master 2 = ManagerSet Up Time Set Up ProgramsTIME Duress Code1 = Add Programs 2 = Show Programs3 = Delete All Programs Times Programs Edit ProgramsEdit Programs When Control Unit / Switch Press Event Buttons Button and Event ProgramsCorresponding Switch Table SwitchOmniLT UPB 6-ButtonKeypadZone Event Buttons All On/Off Event ButtonsX-10Event Buttons Alarm Event ButtonsUPB Link Triggers Miscellaneous Event Buttons Message Event Buttons Pro-LinkProgram Control Commands Edit Program CommandSwitch Press Event Buttons CentraLite Unit Toggle Command Program Security CommandsProgram Button Commands WHEN LINK 1 ON Porch Light STATUSProgram All On / All Off Commands Program Video CommandsProgram Message Commands Edit Program ConditionProgram Security Mode Conditions Program Zone ConditionsProgram Time Clock Conditions Program Other ConditionsAnswer Outside Call Set Up DialTelephone Access Remote Commands Rings Before AnswerDial Type My Phone NumberSet Up Arming Dial Out NumbersDial Order Entry DelayEnable Quick Arm Enable Auto BypassAll On For Alarm Exit DelaySet up Miscellaneous Announce AlarmsEnable Freeze Alarm Flash For AlarmFORMAT NUMBERDESCRIPTION House Code All OffLatitude, Longitude, and Time Zone ZONE NAMESet Up Names Daylight SavingsNUMBER DESCRIPTIONSet Up Voice Set Up Address UNDERWRITERS LABORATORIES REQUIREMENTS FIRE ESCAPE PLANNINGFEDERAL COMMUNICATION COMMISSION NOTICE HAI 21487 Bayou Ct Abita Springs, LACANADIAN INDUSTRY CANADA NOTICE APPENDIX A - SPECIFICATIONS CONTROLLER OUTPUTSUL RATINGS MAXIMUMAPPENDIX B - CHARACTER CODES CODE CHARCODE CHAR CODE CHARAPPENDIX C - VOICE DESCRIPTIONS CODEDESCRIPTION CODECODE DESCRIPTIONCODE DESCRIPTIONCODE DESCRIPTION CODE DESCRIPTIONPage NOTE TO INSTALLER HAI New Orleans, LA U S A