Home Automation SECURITY SYSTEM owner manual Set Up Names, Daylight Savings, Number, Description

Page 70

TIME ZONE:

6

0-12

Daylight Savings

OmniLT automatically calculates the day of daylight savings time each year. It also adjusts the "time of day" each time daylight savings time begins and ends.

To enable the system to properly calculate daylight savings time, a start month, start weekend, end month, and end weekend is set-up at the factory. You may change or disable this function if desired.

DST START MONTH:

4

1-12

0=DISABLE

 

DST START WEEKEND:

FIRST SUNDAY

#=CHNG

DST END MONTH:

10

1-12

0=DISABLE

 

DST END WEEKEND:

#=CHNG

LAST SUNDAY

Set the value for DST Start and End Months to "0" if Daylight Savings Time does not apply to your region, or to disable this automatic time update feature.

The DST Start and End Weekend takes place on the specified Sunday (1-7) at 2:00 AM.

To change the DST Start or End Weekend, press the ' # ' key, then use the arrow keys to scroll through the list. Press the ' # ' key to make the new selection.

NUMBER

DESCRIPTION

1

First Sunday

2

Second Sunday

3

Third Sunday

4

Fourth Sunday

5

Last Sunday

6

Next to Last Sunday

7

Third from Last Sunday

Set Up Names

The system can be set up to display descriptive names such as "FRONT DOOR", "JOHN'S BEDROOM", or "PORCH LIGHT" for zones, units, buttons, codes, temperatures, and messages. These names are displayed instead of the zone, unit, button, code, temperature, or message number that is normally displayed. Zone and Message names may be up to 15 characters long. Each of the other names may be up to 12 characters long.

To enter the Set Up Names menu, from the Setup menu, press the 7 (NAME) key.

SET UP NAME

1=CTRL 2=ZONE 3=BTTN

4=CODE 5=TEMP 8=MSG

Select the item that you would like to name by pressing one of the keys. The current name for the first item (unit, zone, button, code, temperature, or message) is then displayed. Use the arrow keys to scroll through the list of names.

66

Image 70
Contents Document Number 21R00-1Rev. January Document Number 21R00-1Rev. January Copyright 2000-2006HAI All Rights ReservedCONTROL OVERALL DESCRIPTIONSECURITY SYSTEM OPERATION ContentsSETUP TELEPHONE CONTROLINTRODUCTION Underwriters Laboratories UL Listing1- OFF OVERALL DESCRIPTIONConsole Operation 2- DAY6- UP ARROW Normal Top-LevelDisplayDisplay Menus 7- CONSOLE LEDTrouble Beeps Error BeepsMain Menu To silence the beeper, press the * keyConfirmation Beep OmniLT MaintenanceCancel Time Out0 = OFF SECURITY SYSTEM OPERATIONArming the Security System 1 = DAY3 = AWAY Using Shortcut Keys2 = NIGHT 4 = VACATIONBypassing Zones 9 = RESTOREQuick Arm Restoring ZonesWhat Happens When the Alarm is Activated What To Do When You Come HomeBurglar Alarm Activated Emergency Keys Fire Alarm ActivatedGas Alarm Activated OMNIAlarm Cancel Duress Code Entered or Duress Alarm ActivatedAlarm Reset Police EmergencyCodes Trouble IndicationsMaster Code Manager Code Panic SwitchesTesting Your System User CodeCONTROL About UPBHAI Lighting Control HLC Format When set to UPB, the OmniLT controller canRoom Controller LED Indicators About RoomsAbout House Controllers When set to CentraLite, the OmniLT controller canAbout Lutron RadioRA About CentraLiteAbout When set to RadioRA, the OmniLT controller canAbout ALC House CodeControlling Units Configuring Lighting Scenes in an HLC RoomScrolling Through Names Controlling a Room of HLC LightingOperation StepControlling CentraLite Units Controlling RadioRA Units Controlling ALC or X-10UnitsScene Command Compose Timed CommandsRamp Command ALC Controlling Compose UnitsInternal Flags Status of a UnitControlling Outputs All Lights On All On / OffAll Off Scene On Command Scene CommandsScene Set Command Leviton Scene ControlUPB Links Scene Off CommandSetting a Link Lighting Scenes Activating and Deactivating LinksExecuting CentraLite Scenes ButtonsExecuting Phantom Buttons Leave for Work ButtonHAI RC-SeriesThermostats Temperature ControlDinner for Two Button For HAI heat/cool thermostats Programmable Energy Saver Modules PESMs Control actions for temperature sensors Indoor and Outdoor Temperature Freeze AlarmsIMPORTANT NOTES Upstairs 2=LOW 3=HIGH #=STATStatus Temperature AlarmsHumidity Temperature Control of AppliancesConfiguring HLC Devices Configuring HLC Devices using an Omni ConsoleStep Operation Setup Mode for HLC DevicesStep Operation Step OperationRING - RINGING ONHK - ON HOOKOFFHK - OFF HOOK DEAD - DEAD PHONE LINEEvent Log Show EventsShow Message MessagesLog Message Phone Message Clear MessageSay Message Send Message Pro-LinkPro-Linkalso has the capability to monitor the serial port for incoming text messages. When a text message is received, Pro-Linksearches through all 16 messages for a matching message. If one is found, the Program Command macro corresponding to the matching message is activated In-HousePhones TELEPHONE CONTROLTelephone Interface Remote PhonesAlternate Method Phone Access Denied - Remote LockoutMain Menu Panic Button over the Phone # # # # # # PC AccessWhen a Two-WayAudio Module is being used Recording Your AddressVoice Dialer Emergency Dial-OutDigital Dialer How the OmniLT Voice Dialer WorksWhat You Hear - If Your OmniLT Calls You Entering the Code1 = Master SETUPSet Up Codes 2 = ManagerTIME Set Up TimeSet Up Programs Duress Code1 = Add Programs 2 = Show Programs3 = Delete All Programs Edit Programs When Edit ProgramsTimes Programs Control Unit / Switch Press Event Buttons Button and Event ProgramsOmniLT Corresponding Switch TableSwitch UPB 6-ButtonKeypadZone Event Buttons All On/Off Event ButtonsUPB Link Triggers Alarm Event ButtonsX-10Event Buttons Miscellaneous Event Buttons Message Event Buttons Pro-LinkSwitch Press Event Buttons CentraLite Edit Program CommandProgram Control Commands Program Button Commands Unit Toggle CommandProgram Security Commands WHEN LINK 1 ON Porch Light STATUSProgram Message Commands Program All On / All Off CommandsProgram Video Commands Edit Program ConditionProgram Time Clock Conditions Program Security Mode ConditionsProgram Zone Conditions Program Other ConditionsTelephone Access Set Up DialAnswer Outside Call Dial Type Remote CommandsRings Before Answer My Phone NumberDial Order Set Up ArmingDial Out Numbers Entry DelayAll On For Alarm Enable Quick ArmEnable Auto Bypass Exit DelayEnable Freeze Alarm Set up MiscellaneousAnnounce Alarms Flash For AlarmDESCRIPTION FORMATNUMBER House Code All OffLatitude, Longitude, and Time Zone ZONE NAMENUMBER Set Up NamesDaylight Savings DESCRIPTIONSet Up Voice Set Up Address UNDERWRITERS LABORATORIES REQUIREMENTS FIRE ESCAPE PLANNINGFEDERAL COMMUNICATION COMMISSION NOTICE HAI 21487 Bayou Ct Abita Springs, LACANADIAN INDUSTRY CANADA NOTICE UL RATINGS APPENDIX A - SPECIFICATIONSCONTROLLER OUTPUTS MAXIMUMCODE CHAR APPENDIX B - CHARACTER CODESCODE CHAR CODE CHARDESCRIPTION APPENDIX C - VOICE DESCRIPTIONSCODE CODECODE CODEDESCRIPTION DESCRIPTIONCODE DESCRIPTION CODE DESCRIPTIONPage NOTE TO INSTALLER HAI New Orleans, LA U S A