Desa GCP20T, GCP6 GCN10T, GCN6 Troubleshooting, Observed Problem, Possible Cause, Remedy

Page 17
TROUBLESHOOTING

TROUBLESHOOTING

Note: For additional help, visit DESA’s technical service web site at www.desatech.com.

Note: All troubleshooting items are listed in order of operation.

OBSERVED PROBLEM WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.

TROUBLESHOOTING

17

POSSIBLE CAUSE CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed, there is no

1.

Ignitor electrode positioned wrong

1.

Replace pilot assembly

spark at ODS/pilot

2.

Ignitor electrode broken

2.

Replace pilot assembly

 

3.

Ignitor electrode not connected to igni-

3.

Reconnect ignitor cable

 

 

tor cable

 

 

 

 

4.

Ignitor cable pinched or wet

4.

Free ignitor cable if pinched by any

 

 

 

 

metal or tubing. Keep ignitor cable dry

 

5.

Broken ignitor cable

5.

Replace ignitor cable

 

6.

Bad piezo ignitor

6.

Replace piezo ignitor

 

 

 

 

 

When ignitor button is pressed, there is

1.

Gas supply turned off or equipment

1.

Turn on gas supply or open equipment

spark at ODS/pilot but no ignition

 

shutoff valve closed

 

shutoff valve

 

2.

Control knob not in PILOT position

2.

Turn control knob to PILOT position

 

3.

Control knob not pressed in while in

3.

Press in control knob while in PILOT

 

 

PILOT position

 

position

 

4.

Air in gas lines when installed

4.

Continue holding down control knob.

 

 

 

 

Repeat igniting operation until air is re-

 

 

 

 

moved

 

5.

Depleted gas supply (propane/LP only)

5.

Contact local propane/LP gas company

 

6.

ODS/pilot is clogged

6.

Clean ODS/pilot (see Cleaning and

 

 

 

 

Maintenance, page 16) or replace ODS/

 

 

 

 

pilot assembly

 

7.

Gas regulator setting is not correct

7.

Replace gas regulator

 

 

 

 

 

 

ODS/pilot lights but flame goes out when

1.

Control knob not fully pressed in

1.

Press in control knob fully

control knob is released

2.

Control knob not pressed in long enough

2.

After ODS/pilot lights, keep control

 

 

 

 

knob pressed in 30 seconds

 

3. Safety interlock system has been

3.

Wait one minute for safety interlock sys-

 

 

triggered

 

tem to reset. Repeat ignition operation

 

4.

Equipment shutoff valve not fully open

4.

Fully open equipment shutoff valve

 

5.

Thermocouple connection loose at con-

5.

Hand tighten until snug, then tighten 1/4

 

 

trol valve

 

turn more

 

6.

Pilot flame not touching thermocouple,

6.

A) Contact local natural or propane/LP

 

 

which allows thermocouple to cool,

 

gas company

 

 

causing pilot flame to go out. This prob-

 

B) Clean ODS/pilot (see Cleaning and

 

 

lem could be caused by one or both of

 

Maintenance, page 16) or replace ODS/

 

 

the following:

 

pilot assembly

 

 

A) Low gas pressure

 

 

 

 

 

B) Dirty or partially clogged ODS/pilot

 

 

 

 

7.

Thermocouple damaged

7.

Replace pilot assembly

 

8.

Control valve damaged

8.

Replace control valve

REMEDYManual backgroundManual backgroundManual backgroundFor more information, visit www.desatech.com

112157-01A

Image 17
Contents GCN6, GCP6 GCN20T, GCP20TWHAT TO DO IF YOU SMELL GAS Do not try to light any applianceWARNINGS TABLE OF CONTENTSSAFETY INFORMATION SAFETY DEVICE PRODUCT FEATURESUNPACKING PRODUCT IDENTIFICATIONAIR FOR COMBUSTION AND VENTILATION LOCAL CODESPROVIDING ADEQUATE VENTILATION Unusually Tight ConstructionAIR FOR COMBUSTION AND VENTILATION DETERMINING FRESH-AIRFLOW FOR HEATER LOCATIONContinued AIR FOR COMBUSTION AND VENTILATIONVENTILATION AIR INSTALLATIONCHECK GAS TYPE Ventilation Air From Inside BuildingLOCATING HEATER INSTALLATION ITEMSINSTALLATION ContinuedAttaching Thermostat Sensing Bulb Installing Two Mounting ScrewsMarking Screw Locations THERMOSTAT SENSING BULB Thermostat Models OnlyPlacing Heater On Mounting Screws Installing Bottom Mounting ScrewRemoving Front Panel Of Heater Mounting BracketAttaching Mounting Bracket To Wall Methods For Attaching Mounting Bracket To WallINSTALLATION ContinuedPlacing Heater On Mounting Bracket Installing Bottom Mounting ScrewsMounting Base Feet to Heater INSTALLATIONINSTALLATION CONNECTING TO GAS SUPPLYINSTALLATION ContinuedPressure Testing Heater Gas Connections Pressure Testing Gas Supply Piping SystemCHECKING GAS CONNECTIONS INSTALLATIONLIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTINGOPERATING HEATER INSPECTING BURNER MANUAL LIGHTING PROCEDURETO TURN OFF GAS TO APPLIANCE THERMOSTAT CONTROL OPERATION THERMOSTATCABINET CLEANING AND MAINTENANCEODS/PILOT AND BURNER ORIFICE BURNER PILOT AIR INLET HOLEOBSERVED PROBLEM TROUBLESHOOTINGPOSSIBLE CAUSE REMEDYTROUBLESHOOTING Maintenance, pageOBSERVED PROBLEM Continued1. Refer to Fresh Air for Combustion and ing Gas Connections, pageTROUBLESHOOTING OBSERVED PROBLEMMANUAL CONTROL MODELS GCP6 AND GCN6 ILLUSTRATED PARTS BREAKDOWNPILOT ILLUSTRATED PARTS BREAKDOWNPARTS LIST PARTS LISTPART NUMBER GCP6GCP10T GCN10T THERMOSTAT CONTROLLED MODELSILLUSTRATED PARTS BREAKDOWN PILOTPARTS LIST PARTS LISTPART NUMBER GCP10TMODELS THERMOSTAT CONTROLLEDGCN20T AND GCP20T ILLUSTRATED PARTS BREAKDOWNPARTS LIST PARTS LISTPART NUMBER GCN20TSERVICE CENTER/PARTS CENTRAL SPECIFICATIONSGCP6 GCP10TOWNERS REGISTRATION FORM TAPE Postage Required2701 Industrial Drive P.O. Box Bowling Green, KY TAPESERVICE PUBLICATIONS REPLACEMENT PARTSACCESSORIES SERVICE HINTSLIMITED WARRANTY VENT-FREERESIDENTIAL GAS HEATERS WARRANTY INFORMATIONemail desacan@sympatico.ca Model Serial No Date PurchasedD’ÉVACUATION RADIATEUR À GAZ À FLAMME BLEUE SANS CONDUITINFORMATIONS RELATIVES À LA SÉCURITÉ ET MODE D’EMPLOIAVERTISSEMENTS TABLE DES MATIÈRESINFORMATIONS RELATIVES À LA SÉCURITÉ IDENTIFICATION DU PRODUIT DÉBALLAGECARACTÉRISTIQUES DU PRODUIT SuiteAIR POUR LA COMBUSTION ET LA VENTILATION CODES LOCAUXPOUR FOURNIR UNE VENTILATION ADÉ QUATE Construction particuliè rement é tancheque l’espace peut supporter OU AIR POUR LA COMBUSTION ET LA VENTILATIONSuite VÉ RIFIEZ LE TYPE DE GAZ AIR DE VENTILATIONAir de ventilation de l’inté rieur du bâ timent Air de ventilation de l’exté rieurPLACEMENT DU RADIATEUR ARTICLES POUR L’INSTALLATIONINSTALLATION AVERTISSEMENT Ne jamais installer le radiateurInstallation des deux vis de montage Marquage de l’emplacement des visBULBE THERMOSTATIQUE modè les à thermostat uniquementInstallation de la vis de montage infé rieure Placement du radiateur sur les vis de montageRetrait du panneau avant du radiateur Support de montageINSTALLATION Fixation du support de montage au murMarquage de l’emplacement des vis SuiteInstallation des vis de montage infé rieures Placement du radiateur sur le support de montageMontage des pieds sur le radiateur Montage des pieds au sol si le code local l’exigeSuite RACCORDEMENT À L’ALIMENTATION EN GAZINSTALLATION Suite VÉ RIFICATION DES CONNEXIONS AU GAZINSTALLATION INSTRUCTIONS D’ ALLUMAGE UTILISATION DU RADIATEURPOUR VOTRE SÉ CURITÉ - À LIRE AVANT L’ALLUMAGE POUR COUPER LE GAZ DE L’APPAREIL INSPECTION DU BRÛLEURUTILISATION DU CONTRÔ LE PAR THERMOSTAT MODÈ LES À THERMOSTAT UNIQUEMENTODS/VEILLEUSE ET ORIFICE DU BRÛ LEUR NETTOYAGE ET ENTRETIENHABILLAGE Conduits d’airDÉPANNAGE SOLUTIONSYMPTÔ ME CAUSE POSSIBLEDÉPANNAGE SOLUTIONSuite SYMPTÔ MEDÉPANNAGE SOLUTIONSuite SYMPTÔ MEMODÈ LES À CONTRÔ LE MANUEL GCP6 ET GCN6 VUE DÉTAILLÉE DU RADIATEURVEILLEUSE VUE DÉTAILLÉE DU RADIATEURLISTE DES PIÈCES LISTE DES PIÈCESNUMÉ RO DE PIÈ CE GCP6GCP10T ET GCN10T MODÈ LES CONTRÔ LÉ S PAR THERMOSTATVUE DÉTAILLÉE DU RADIATEUR VEILLEUSELISTE DES PIÈCES LISTE DES PIÈCESNUMÉ RO DE PIÈ CE GCP10TTHERMOSTAT MODÈ LES CONTRÔ LÉ S PARGCN20T ET GCP210T VUE DÉTAILLÉE DU RADIATEURLISTE DES PIÈCES LISTE DES PIÈCESNUMÉ RO DE PIÈ CE GCN20TSPÉCIFICATIONS CENTRE DE SERVICE/DÉPÔT DE PIÈCESPage RUBAN Affran chissement RequisRUBAN 2701 Industrial Drive P.O. Box Bowling Green, KYACCESSOIRES PUBLICATIONS POUR LE SERVICECONSEILS DE SERVICE SERVICE TECHNIQUEGARANTIE LIMITÉE INFORMATION SUR LA GARANTIENOT A UPC 2220, Argentia Road, Unité 4 Mississauga, Ontario