Mt. Vernon Pellet Insert (AE)
R
7Appliance Set-Up
A. Leveling System
The leveling bolts are located on the sides of the appliance, front and rear. To access the bolts, remove the front access panels. Reach in and turn the bolt to the desired height to level the appliance.
Leveling Bolts - 2 on each side
Figure 20.1
B. Outside Air Kit Instructions
Included in Kit: 2 wire ties, 1 collar assembly,
1 termination cap assembly, 1 trim ring, fasteners.
NOTE: 3 INCH (76mm) ALUMINUM FLEX PIPE NOT INCLUDED.
Tools Needed: Phillips head screw driver; wire cutters; hole saw or jig saw.
1.Measure distance from fl oor to air vent opening in appli- ance and mark location on wall.
2.Use saw to cut opening in wall. Cut a
3.Use wire ties to secure fl ex pipe to collar assembly.
4.Slide trim ring over fl ex pipe and run pipe through wall.
5.Attach fl ex pipe (not included) to outside termination cap with second wire tie.
6.Secure termination cap to outside surface.
7.Secure trim ring to interior wall.
CAUTION
Never draw outside combustion air from:
•Wall, fl oor or ceiling cavity
•Enclosed space such as an attic or garage
| Collar |
|
| Wire Ties |
|
|
| 3 inch Aluminum Flex |
|
| Pipe (not included) |
| Trim Ring |
|
| Termination Cap |
|
| Figure 20.2 |
|
Page 20 | November 22, 2011 |