Quadra-Fire MTVERNINSAE-MBK owner manual Mt. Vernon Pellet Insert AE Surround and Trim Set Cast

Page 22

Mt. Vernon Pellet Insert (AE)

E. Surround and Trim Set - Cast

Included in Surround Kit: (2) side panels, left and right; (1) panel top; (1) fastener package.

Included in Cast Trim Kit: (2) cast trim legs, left and right; (1) cast trim header; (2) cast trim footers, left and right; (1) fastener package.

Tools Needed: Powered Phillips head screw driver

1.Remove contents from box being careful not to scratch or damage the cast trim pieces.

2.Lay the surround set face down on protective covering to prevent scratching the painted surface.

3.Secure the surround legs to top panel with the screws provided.

4.Now bend the tabs down toward the backside of the panel set, 5 on top and 2 on each leg. Leave the panel set face down. Figure 22.1.

5.Place the corresponding cast trim pieces ( 2 cast trim legs and 1 cast trim header) underneath the panel set, also face down.

6.Place washer provided over tab and secure the trim and panel together with screw. Continue for all tabs.

7.Secure cast footers with screws.

8.Remove both left and right cast sides from insert. See Figure

21.4page 21.

9.Carefully slide surround and trim over the top of the insert into place matching the mounting holes on the panel with the mounting holes on the insert. Secure with screws provided. Figure 22.5.

2. Bend tabs down

1. Screw panels

together

 

1. Screw panels

 

together

 

 

2. Bend tabs

 

down

3. Install Cast Trim Header

 

Figure 22.1

R

F. Surround & Trim Set, Basic

Included in Surround & Trim Kit: (2) corner brackets and set screws; (1) trim set, 3 piece; (2) side panels; (1) top panel;

(4) screws.

Tools Needed: Powered Phillips head screw driver

1.Secure the top panel to the surround sides with the screws provided. Figure 22.3.

2.Assemble the trim with the (2) corner brackets provided. Figure 22.4.

3.Remove the 2 cast sides and slide the assembled trim over the assembled surround set. See Figure 21.4 on page 21.

4.Carefully slide surround and trim over the top of the insert into place matching the mounting holes on the panel with the mounting holes on the insert. Secure with screws provided. Figure 22.5.

Back of Top Panel

Screws

Back of Side Panel

Figure 22.3

Figure 22.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shown with trim installed on panel set

 

Figure 22.2- Completed View

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 22.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 22

7036-135G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

November 22, 2011

Image 22
Contents Installation and Operation Hot glass will cause burnsMt. Vernon Pellet Insert AE Label Location On Beaded Chain on e behind Right Side PanelTable of Contents Mobile Home Approved Listing and Code ApprovalsAppliance Certifi cation Glass Specifi cationsAppliance Location Design, Installation & Location ConsiderationsGetting Started Floor SupportPre-Use Check List Tools And Supplies NeededInspect Appliance and Components Thermostat Wall Control Location3Dimensions and Clearances Appliance DimensionsInch Clearance To Exposed Section And Face Trim Built-in Unit Rear Vent with Outside AirFloor Protection Mt. Vernon Pellet Insert AE Built-In VerticalMasonry and Zero Clearance Fireplaces Minimum Opening for Masonry and Zero Clearance FireplacesStarter hole Mark area of floor to cut Mt. Vernon Pellet Insert AE Prefabricated Metal Chimney Altering the Factory-Built FireplaceDo not Terminate Vent 4Vent InformationVenting Termination Minimum Requirements Termination must exhaust above air inlet elevationMt. Vernon Pellet Insert AE Avoiding Smoke and Odors Negative Pressure, Shut-Down and Electrical Power FailureOptional Battery Back-Up Outside AirMt. Vernon Pellet Insert AE Negative Pressure Draft Equivalent Feet of Pipe Mt. Vernon Pellet Insert AE Chimney and Exhaust ConnectionExample of 3 Elbow-Rear Vent Termination Calculation Mt. Vernon Pellet Insert AE Pipe Selection Chart Altitude in Thousands of Feet5Venting Systems Full Reline With Outside Air Horizontal305mm min. above 305mm min. below Never Install in a Sleeping Room 6Mobile HomeLeveling System 7Appliance Set-UpOutside Air Kit Instructions Mt. Vernon Pellet Insert AE Hearth Support Removal of Cast SidesMt. Vernon Pellet Insert AE Surround and Trim Set Cast Surround & Trim Set, BasicRebox. Figures 23.1 Optional Log Set Placement InstructionsRebox. Figures 23.3 7036-135G November 22 Combustible/Non-Combustible Materials Fire Safety8Operating Instructions Fuel Material and Fuel StorageAuto-Clean Firepot System Thermostat Wall Control Automatic SettingThermostat Wall Control Manual Setting General Operating InformationFilling the Hopper with Fuel Fire Characteristics and Flame Height Feed Rate AdjustmentMt. Vernon Pellet Insert AE Before Your First Fire Starting Your First FireMt. Vernon Pellet Insert AE Battery Back-up System Optional Clear SpaceMt. Vernon Pellet Insert AE Ignition Cycles Insert Removal Auto-Clean CycleAdditional Screen Messages Mt. Vernon Pellet Insert AE Quick Start Guide Or CWall Control for Reference 74ºF Frequently Asked Questions Issues SolutionsError Message Possible Cause Corrective Action10Maintaining & Servicing Your Appliance Quick Reference Maintenance ChartProper Shutdown Procedure Before Servicing Your ApplianceCleaning Ash Pan General Maintenance and CleaningAuto-Clean System Inspection & Cleaning Ash Removal from FireboxLarge Clinker Cleaning Heat Exchanger, Drop Tube & Exhaust Example of a dirty heat exchangerLoosen all 6 nuts, but do not Remove Door Latch Inspection Cleaning the HopperCleaning the Glass Preparing Firebox for Non-Burn SeasonBaffl e Removal Fire and Smoke RiskGlass Replacement Convection Blower ReplacementConvection Blower Replacement Cont’d Convection Blower ReplacementReference Materials Overheat Sensor Snap Disc Power SupplyThermocouple on Drop Tube Vacuum Switch Thermocouple FirepotFeed Motor, Vacuum Switch, Exhaust Blower, Overheat Sensor Mt. Vernon Pellet Insert AE Component LocationsMt. Vernon Pellet Insert AE Exploded Drawings Part number list on following pagesStocked at Depot Stocked At Depot#38 Feed Assembly 38.5 38.6 38.4 38.3 38.2 38.1 Stocked at Depot #39 Firepot Riser Assembly #40 Auto-Clean Motor/Arm AssemblyStocked At DepotFasteners Accessories SP-MTVS-GDMt. Vernon Pellet Insert AE Mt. Vernon Pellet Insert AE Contact Information