Quadra-Fire MTVERNINSAE-MBK, MTVERNINSAE-CSB Stocked at Depot #39 Firepot Riser Assembly

Page 50

Mt. Vernon Pellet Insert (AE)

R

IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer.

ITEM

DESCRIPTION

COMMENTS

PART NUMBER

 

 

 

 

Stocked at Depot

#39 Firepot Riser Assembly

39.1

39.2

39.3

39.4

39.5

39.11

39.10

39.6

39.9

39.8

39.7

#40 Auto-Clean Motor/Arm Assembly

40

40.1

40.7

40.2 40.6

40.340.5

40.4

39

Firepot Riser Assembly

 

SRV7034-002

 

 

 

 

 

 

39.1

Thermocouple, K

 

SRV7034-247

Y

 

 

 

 

 

39.2

Half Clip

 

7000-321

 

 

 

 

 

 

39.3

Thermocouple Protection Tube

 

SRV7034-186

Y

 

 

 

 

 

39.4

Firepot Assembly

 

SRV7034-072

Y

 

 

 

 

 

39.5

Gasket, Firepot

 

7034-190

Y

 

 

 

 

 

39.6

Auto-Clean Link Arm

 

7034-176

Y

 

 

 

 

 

39.7

Plow Weldment, Auto-Clean

 

7034-024

Y

 

 

 

 

 

39.8

Rail, Auto-Clean

 

SRV7034-152

Y

 

 

 

 

 

39.9

Spring

Pkg of 4

7000-513/4

Y

 

 

 

 

 

39.10

Hitch Pin Clip 3/32

Pkg of 10

7000-374/10

Y

 

 

 

 

 

39.11

Firepot Bottom

 

7034-153

Y

 

 

 

 

 

 

Auto-Clean Bottom Assembly

 

7034-021

Y

 

 

 

 

 

 

Firepot Riser Clamp Assembly

 

7034-012

 

 

 

 

 

 

40

Auto-Clean Motor/Arm Assembly

 

SRV7034-020

Y

 

 

 

 

 

40.1

Auto-Clean Lever

 

7034-158

Y

 

 

 

 

 

40.2

Micro Switch No

 

7000-327

Y

 

 

 

 

 

40.3

Gear Motor 12V

 

7000-300

Y

 

 

 

 

 

40.4

Grommet, Motor, Auto-Clean

 

7034-188

Y

 

 

 

 

 

40.5

Cam, Switch, Auto-Clean

 

SRV7034-187

Y

 

 

 

 

 

40.6

Bearing

 

7000-333

Y

 

 

 

 

 

40.7

Gasket, Auto-Clean

 

7034-165

Y

 

 

 

 

 

Additional service part numbers appear on following page.

Page 50

7036-135G

November 22, 2011

Image 50
Contents Installation and Operation Hot glass will cause burnsMt. Vernon Pellet Insert AE Label Location On Beaded Chain on e behind Right Side PanelTable of Contents Mobile Home Approved Listing and Code ApprovalsAppliance Certifi cation Glass Specifi cationsAppliance Location Design, Installation & Location ConsiderationsGetting Started Floor SupportPre-Use Check List Tools And Supplies NeededInspect Appliance and Components Thermostat Wall Control Location3Dimensions and Clearances Appliance DimensionsInch Clearance To Exposed Section And Face Trim Built-in Unit Rear Vent with Outside AirFloor Protection Mt. Vernon Pellet Insert AE Built-In VerticalMasonry and Zero Clearance Fireplaces Minimum Opening for Masonry and Zero Clearance FireplacesStarter hole Mark area of floor to cut Mt. Vernon Pellet Insert AE Prefabricated Metal Chimney Altering the Factory-Built FireplaceDo not Terminate Vent 4Vent InformationVenting Termination Minimum Requirements Termination must exhaust above air inlet elevationMt. Vernon Pellet Insert AE Avoiding Smoke and Odors Negative Pressure, Shut-Down and Electrical Power FailureOptional Battery Back-Up Outside AirMt. Vernon Pellet Insert AE Negative Pressure Draft Example of 3 Elbow-Rear Vent Termination Calculation Mt. Vernon Pellet Insert AE Chimney and Exhaust ConnectionEquivalent Feet of Pipe Mt. Vernon Pellet Insert AE Pipe Selection Chart Altitude in Thousands of Feet5Venting Systems Full Reline With Outside Air Horizontal305mm min. above 305mm min. below Never Install in a Sleeping Room 6Mobile HomeOutside Air Kit Instructions 7Appliance Set-UpLeveling System Mt. Vernon Pellet Insert AE Hearth Support Removal of Cast SidesMt. Vernon Pellet Insert AE Surround and Trim Set Cast Surround & Trim Set, BasicRebox. Figures 23.3 Optional Log Set Placement InstructionsRebox. Figures 23.1 7036-135G November 22 Combustible/Non-Combustible Materials Fire Safety8Operating Instructions Fuel Material and Fuel StorageAuto-Clean Firepot System Thermostat Wall Control Automatic SettingThermostat Wall Control Manual Setting General Operating InformationFilling the Hopper with Fuel Fire Characteristics and Flame Height Feed Rate AdjustmentMt. Vernon Pellet Insert AE Before Your First Fire Starting Your First FireMt. Vernon Pellet Insert AE Battery Back-up System Optional Clear SpaceMt. Vernon Pellet Insert AE Ignition Cycles Additional Screen Messages Auto-Clean CycleInsert Removal Wall Control for Reference Or CMt. Vernon Pellet Insert AE Quick Start Guide 74ºF Frequently Asked Questions Issues SolutionsError Message Possible Cause Corrective Action10Maintaining & Servicing Your Appliance Quick Reference Maintenance ChartProper Shutdown Procedure Before Servicing Your ApplianceCleaning Ash Pan General Maintenance and CleaningAuto-Clean System Inspection & Cleaning Ash Removal from FireboxLarge Clinker Cleaning Heat Exchanger, Drop Tube & Exhaust Example of a dirty heat exchangerLoosen all 6 nuts, but do not Remove Door Latch Inspection Cleaning the HopperCleaning the Glass Preparing Firebox for Non-Burn SeasonBaffl e Removal Fire and Smoke RiskGlass Replacement Convection Blower ReplacementConvection Blower Replacement Cont’d Convection Blower ReplacementReference Materials Overheat Sensor Snap Disc Power SupplyThermocouple on Drop Tube Vacuum Switch Thermocouple FirepotFeed Motor, Vacuum Switch, Exhaust Blower, Overheat Sensor Mt. Vernon Pellet Insert AE Component LocationsMt. Vernon Pellet Insert AE Exploded Drawings Part number list on following pagesStocked at Depot Stocked At Depot#38 Feed Assembly 38.5 38.6 38.4 38.3 38.2 38.1 Stocked at Depot #39 Firepot Riser Assembly #40 Auto-Clean Motor/Arm AssemblyStocked At DepotFasteners Accessories SP-MTVS-GDMt. Vernon Pellet Insert AE Mt. Vernon Pellet Insert AE Contact Information