Quadra-Fire MTVERNINSAE-PMH, MTVERNINSAE-CSB #38 Feed Assembly 38.5 38.6 38.4 38.3 38.2 38.1

Page 49

R

Mt. Vernon Pellet Insert (AE)

IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer.

ITEM

DESCRIPTION

COMMENTS

PART NUMBER

 

 

 

 

Stocked at Depot

30

Combustion Blower Assembly

 

 

7034-033

Y

 

 

 

 

 

 

 

Gasket, Blower, Combustion

(Between …)

...Housing & Stove

SRV7000-332

Y

 

 

 

 

 

 

 

Gasket, Motor, Blower, Combustion

(Between …)

...Housing & Motor

SRV7000-423

Y

 

 

 

 

 

 

31

Control Board Assembly

 

 

SRV7000-456

Y

 

 

 

 

 

 

 

Fuse 15A Slow Iec Glass

 

Pkg of 10

7000-491/10

Y

 

 

 

 

 

 

32

Convection Blower

 

 

SRV7000-260

Y

 

 

 

 

 

 

33

Gasket, Blower, Convection

 

 

7000-329

 

 

 

 

 

 

 

 

 

 

Pre 00700201366

7000-376

Y

34Detent Pin

 

Post 00700201366

7000-393

 

 

 

 

 

35

Exhaust Transition & Flue Assembly

SRV7036-029

 

 

 

 

 

 

Gasket, Flue Adapter

240-0850

Y

 

 

 

 

 

Latch, Draw

229-0230

 

 

 

 

 

36

Snap Disc, Manual Reset

SRV230-1290

Y

 

 

 

 

37

Bracket, Hopper Magnet

7036-149

 

#38 Feed Assembly

38.5

38.6

38.4

38.3

38.2

38.1

38

Feed Assembly

 

SRV7034-004

Y

 

 

 

 

 

38.1

Feed Spring Assembly (Only)

 

SRV7001-046

Y

 

 

 

 

 

38.2

Bearing, Feed System, Nylon

 

410-0552

Y

 

 

 

 

 

38.3

Gasket, Feed Motor

 

7034-144

 

 

 

 

 

 

38.4

Bracket, Motor, Feed

 

7034-143

 

 

 

 

 

 

38.5

Optical Switch Assembly

 

7034-038

Y

 

 

 

 

 

38.6

Feed Motor DC

 

SRV7000-313

Y

 

 

 

 

 

 

Collar, Set, 7/8

 

229-0520

 

 

 

 

 

 

Additional service part numbers appear on following page.

November 22, 2011

7036-135G

Page 49

Image 49
Contents Hot glass will cause burns Installation and OperationLabel Location On Beaded Chain on e behind Right Side Panel Mt. Vernon Pellet Insert AETable of Contents Appliance Certifi cation Listing and Code ApprovalsMobile Home Approved Glass Specifi cationsGetting Started Design, Installation & Location ConsiderationsAppliance Location Floor SupportInspect Appliance and Components Tools And Supplies NeededPre-Use Check List Thermostat Wall Control LocationAppliance Dimensions 3Dimensions and ClearancesBuilt-in Unit Rear Vent with Outside Air Inch Clearance To Exposed Section And Face TrimMasonry and Zero Clearance Fireplaces Mt. Vernon Pellet Insert AE Built-In VerticalFloor Protection Minimum Opening for Masonry and Zero Clearance FireplacesStarter hole Mark area of floor to cut Altering the Factory-Built Fireplace Mt. Vernon Pellet Insert AE Prefabricated Metal ChimneyVenting Termination Minimum Requirements 4Vent InformationDo not Terminate Vent Termination must exhaust above air inlet elevationOptional Battery Back-Up Negative Pressure, Shut-Down and Electrical Power FailureMt. Vernon Pellet Insert AE Avoiding Smoke and Odors Outside AirMt. Vernon Pellet Insert AE Negative Pressure Draft Equivalent Feet of Pipe Mt. Vernon Pellet Insert AE Chimney and Exhaust ConnectionExample of 3 Elbow-Rear Vent Termination Calculation Altitude in Thousands of Feet Mt. Vernon Pellet Insert AE Pipe Selection ChartFull Reline With Outside Air Horizontal 5Venting Systems305mm min. above 305mm min. below 6Mobile Home Never Install in a Sleeping RoomLeveling System 7Appliance Set-UpOutside Air Kit Instructions Removal of Cast Sides Mt. Vernon Pellet Insert AE Hearth SupportSurround & Trim Set, Basic Mt. Vernon Pellet Insert AE Surround and Trim Set CastRebox. Figures 23.1 Optional Log Set Placement InstructionsRebox. Figures 23.3 7036-135G November 22 8Operating Instructions Fire SafetyCombustible/Non-Combustible Materials Fuel Material and Fuel StorageThermostat Wall Control Manual Setting Thermostat Wall Control Automatic SettingAuto-Clean Firepot System General Operating InformationMt. Vernon Pellet Insert AE Before Your First Fire Fire Characteristics and Flame Height Feed Rate AdjustmentFilling the Hopper with Fuel Starting Your First FireClear Space Mt. Vernon Pellet Insert AE Battery Back-up System OptionalMt. Vernon Pellet Insert AE Ignition Cycles Insert Removal Auto-Clean CycleAdditional Screen Messages Mt. Vernon Pellet Insert AE Quick Start Guide Or CWall Control for Reference 74ºF Issues Solutions Frequently Asked QuestionsPossible Cause Corrective Action Error MessageProper Shutdown Procedure Quick Reference Maintenance Chart10Maintaining & Servicing Your Appliance Before Servicing Your ApplianceAuto-Clean System Inspection & Cleaning General Maintenance and CleaningCleaning Ash Pan Ash Removal from FireboxExample of a dirty heat exchanger Large Clinker Cleaning Heat Exchanger, Drop Tube & ExhaustLoosen all 6 nuts, but do not Remove Cleaning the Glass Cleaning the HopperDoor Latch Inspection Preparing Firebox for Non-Burn SeasonFire and Smoke Risk Baffl e RemovalConvection Blower Replacement Glass ReplacementConvection Blower Replacement Convection Blower Replacement Cont’dReference Materials Thermocouple on Drop Tube Vacuum Switch Power SupplyOverheat Sensor Snap Disc Thermocouple FirepotMt. Vernon Pellet Insert AE Component Locations Feed Motor, Vacuum Switch, Exhaust Blower, Overheat SensorPart number list on following pages Mt. Vernon Pellet Insert AE Exploded DrawingsStocked at Depot At Depot Stocked#38 Feed Assembly 38.5 38.6 38.4 38.3 38.2 38.1 #40 Auto-Clean Motor/Arm Assembly Stocked at Depot #39 Firepot Riser AssemblyAt Depot StockedFasteners SP-MTVS-GD AccessoriesMt. Vernon Pellet Insert AE Mt. Vernon Pellet Insert AE Contact Information