Mt. Vernon Pellet Insert (AE)

R

I. Battery Back-up System (Optional)

CAUTION!

Hook up to battery terminals BEFORE you plug battery into appliance.

Damage to internal electronic components may occur.

The appliance has been designed to operate on an optional battery back-up system.

If you have frequent power outages in your region, hook the appliance up to a 12 volt battery and it will automatically switch to battery power in the event of a power failure. The 12 volt power cord, sold as a separate accessory, does not charge the battery.

WARNING! Risk of Injury!

Blowers may continue to run and would be exposed to human contact.

Operating on Battery Back-Up

A battery icon appears on your wall control to let you know you are now operating on battery power. Figure 28.2.

The fi re must be manually lit as the appliance will no longer automatically light. Follow the instructions in the Wall Control Manual.

Use only approved fi re starting gel to start the fi re.

The high burn rate is no longer available on battery back-up.

Each level drops down one level, i.e the high burn be- comes medium-high burn and so on.

If the battery charge falls below 10 volt it can no longer sustain the appliance operation and the appliance will shut down. Figure 28.1. You must disconnect and re- connect the battery to start it up again.

Recommended Battery

12 volt deep cycle battery, (i.e., marine or RV type).

A 12 volt battery cable is available through your local dealer.

Battery

13 Volts 12 Volts 11 Volts Below

10 Volts

Figure 28.1

Wall Control Display

The wall control will display the battery icon when operating in the battery back-up mode. Figure 28.2

“Maint Burn” will display when the thermostat has reached the set room temperature and will run on low until it reaches its auto-clean cycle time.

MAINT BURN

 

 

12:30 PM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set at: 73

 

 

73

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MENU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEAT OUTPUT

 

 

 

 

 

 

 

Battery icon.

Figure 28.2

J. Clear Space

WARNING! RISK OF FIRE! Do NOT place combustible objects in front of the appliance. High temperatures may ignite clothing, furniture or draperies. Maintain a minimum clearance of 3 feet (914mm) in front of appliance.

Mantel: Avoid placing candles and other heat-sensitive objects on mantel or hearth. Heat may damage these objects.

NOTICE: Clearances may only be reduced by means ap- proved by the regulatory authority having jurisdiction.

WARNING! RISK OF FIRE! Keep combustible materials, gasoline and other fl ammable vapors and liquids clear of appliance.

Do NOT store fl ammable materials in the appliance’s vicinity.

DO NOT USE GASOLINE, LANTERN FUEL, KEROSENE, CHARCOAL LIGHTER FLUID OR SIMILAR LIQUIDS TO START OR “FRESHEN UP” A FIRE IN THIS HEATER.

DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH AS GASOLINE, NAPHTHA OR ENGINE OIL.

DO NOT USE CHEMICALS OF FLUIDS TO START THE FIRE.

Keep all such liquids well away from the heater while it is in use as combustible materials may ignite.

Page 28

7036-135G

November 22, 2011

Image 28
Contents Installation and Operation Hot glass will cause burnsMt. Vernon Pellet Insert AE Label Location On Beaded Chain on e behind Right Side PanelTable of Contents Listing and Code Approvals Appliance Certifi cationMobile Home Approved Glass Specifi cationsDesign, Installation & Location Considerations Getting StartedAppliance Location Floor SupportTools And Supplies Needed Inspect Appliance and ComponentsPre-Use Check List Thermostat Wall Control Location3Dimensions and Clearances Appliance DimensionsInch Clearance To Exposed Section And Face Trim Built-in Unit Rear Vent with Outside AirMt. Vernon Pellet Insert AE Built-In Vertical Masonry and Zero Clearance FireplacesFloor Protection Minimum Opening for Masonry and Zero Clearance FireplacesStarter hole Mark area of floor to cut Mt. Vernon Pellet Insert AE Prefabricated Metal Chimney Altering the Factory-Built Fireplace4Vent Information Venting Termination Minimum RequirementsDo not Terminate Vent Termination must exhaust above air inlet elevationNegative Pressure, Shut-Down and Electrical Power Failure Optional Battery Back-UpMt. Vernon Pellet Insert AE Avoiding Smoke and Odors Outside AirMt. Vernon Pellet Insert AE Negative Pressure Draft Equivalent Feet of Pipe Mt. Vernon Pellet Insert AE Chimney and Exhaust ConnectionExample of 3 Elbow-Rear Vent Termination Calculation Mt. Vernon Pellet Insert AE Pipe Selection Chart Altitude in Thousands of Feet5Venting Systems Full Reline With Outside Air Horizontal305mm min. above 305mm min. below Never Install in a Sleeping Room 6Mobile HomeLeveling System 7Appliance Set-UpOutside Air Kit Instructions Mt. Vernon Pellet Insert AE Hearth Support Removal of Cast SidesMt. Vernon Pellet Insert AE Surround and Trim Set Cast Surround & Trim Set, BasicRebox. Figures 23.1 Optional Log Set Placement InstructionsRebox. Figures 23.3 7036-135G November 22 Fire Safety 8Operating InstructionsCombustible/Non-Combustible Materials Fuel Material and Fuel StorageThermostat Wall Control Automatic Setting Thermostat Wall Control Manual SettingAuto-Clean Firepot System General Operating InformationFire Characteristics and Flame Height Feed Rate Adjustment Mt. Vernon Pellet Insert AE Before Your First FireFilling the Hopper with Fuel Starting Your First FireMt. Vernon Pellet Insert AE Battery Back-up System Optional Clear SpaceMt. Vernon Pellet Insert AE Ignition Cycles Insert Removal Auto-Clean CycleAdditional Screen Messages Mt. Vernon Pellet Insert AE Quick Start Guide Or CWall Control for Reference 74ºF Frequently Asked Questions Issues SolutionsError Message Possible Cause Corrective ActionQuick Reference Maintenance Chart Proper Shutdown Procedure10Maintaining & Servicing Your Appliance Before Servicing Your ApplianceGeneral Maintenance and Cleaning Auto-Clean System Inspection & CleaningCleaning Ash Pan Ash Removal from FireboxLarge Clinker Cleaning Heat Exchanger, Drop Tube & Exhaust Example of a dirty heat exchangerLoosen all 6 nuts, but do not Remove Cleaning the Hopper Cleaning the GlassDoor Latch Inspection Preparing Firebox for Non-Burn SeasonBaffl e Removal Fire and Smoke RiskGlass Replacement Convection Blower ReplacementConvection Blower Replacement Cont’d Convection Blower ReplacementReference Materials Power Supply Thermocouple on Drop Tube Vacuum SwitchOverheat Sensor Snap Disc Thermocouple FirepotFeed Motor, Vacuum Switch, Exhaust Blower, Overheat Sensor Mt. Vernon Pellet Insert AE Component LocationsMt. Vernon Pellet Insert AE Exploded Drawings Part number list on following pagesStocked at Depot Stocked At Depot#38 Feed Assembly 38.5 38.6 38.4 38.3 38.2 38.1 Stocked at Depot #39 Firepot Riser Assembly #40 Auto-Clean Motor/Arm AssemblyStocked At DepotFasteners Accessories SP-MTVS-GDMt. Vernon Pellet Insert AE Mt. Vernon Pellet Insert AE Contact Information