Mt. Vernon Pellet Insert (AE)

R

IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement

 

 

parts for your appliance please provide model number and serial number. All parts listed

 

Stocked

in this manual may be ordered from an authorized dealer.

 

 

at Depot

ITEM

 

DESCRIPTION

COMMENTS

PART NUMBER

 

 

 

 

 

 

 

 

 

 

 

#19 Door Assembly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

19.1

19.2

19.3

19.7

19.6

19.5

19.4

19

Door Assembly

 

7034-006

 

 

 

 

 

 

19.1

Hinge, Female

 

450-2910

 

 

 

 

 

 

19.2

Door Air Defl ector

 

7034-185

 

 

 

 

 

 

19.3

Magnet Bracket Assembly

 

7034-008

 

 

 

 

 

 

 

Magnet Round

 

SRV7000-140

Y

 

 

 

 

 

19.4

Door Frame Assembly

 

7034-026

 

 

 

 

 

 

19.5

Door Latch Assembly

 

7034-039

 

 

 

 

 

 

19.6

Glass Assembly

21” W x 14” H

7034-007

Y

 

 

 

 

 

 

Gasket, Channel 3 Mm X 32 - Field Cut to Size

10 Ft

7000-377/10

Y

 

 

 

 

 

 

Tape, Door Corner - - Field Cut to Size

1 Ft

SRV7027-227

Y

 

 

 

 

 

19.7

Glass Retainer

 

7034-136

 

 

 

 

 

 

20

Ash Pan Door

 

7034-133

 

 

 

 

 

 

21

Ash Pan Assembly

 

SRV7034-069

 

 

 

 

 

 

 

Roller Catch

Pret SN 0070020465

SRV7000-494

Y

 

 

 

 

 

 

Twin Ball catch

Post SN 0070020465

SRV7000-532

Y

 

 

 

 

 

 

 

Matte Black

7036-109MBK

 

 

 

 

 

 

22

Bottom

Sienna Bronze

7036-109CSB

 

 

 

 

Willow

7036-109CWL

 

 

 

 

 

 

 

 

 

 

 

Mahogany

7036-109PMH

 

 

 

 

 

 

23

Gasket, Rope, Ash Door

 

SRV7034-178

Y

 

 

 

 

 

24

Gasket, Door Rope

 

SRV7034-177

Y

 

 

 

 

 

25

Magnetic Switch

 

7000-375

Y

 

 

 

 

 

26

Latch Bracket Assembly

 

7034-049

Y

 

 

 

 

 

 

 

Matte Black

7036-103MBK

 

 

 

 

 

 

27

Side

Sienna Bronze

7036-103CSB

 

 

 

 

Willow

7036-103CWL

 

 

 

 

 

 

 

 

 

 

 

Mahogany

7036-103PMH

 

 

 

 

 

 

28

Vacuum Switch

 

SRV7000-531

Y

 

 

 

 

 

29

Power Supply Assembly

 

SRV7000-443

Y

 

 

 

 

 

Additional service part numbers appear on following page.

Page 48

7036-135G

November 22, 2011

Image 48
Contents Installation and Operation Hot glass will cause burnsMt. Vernon Pellet Insert AE Label Location On Beaded Chain on e behind Right Side PanelTable of Contents Listing and Code Approvals Appliance Certifi cationMobile Home Approved Glass Specifi cationsDesign, Installation & Location Considerations Getting StartedAppliance Location Floor SupportTools And Supplies Needed Inspect Appliance and ComponentsPre-Use Check List Thermostat Wall Control Location3Dimensions and Clearances Appliance DimensionsInch Clearance To Exposed Section And Face Trim Built-in Unit Rear Vent with Outside AirMt. Vernon Pellet Insert AE Built-In Vertical Masonry and Zero Clearance FireplacesFloor Protection Minimum Opening for Masonry and Zero Clearance FireplacesStarter hole Mark area of floor to cut Mt. Vernon Pellet Insert AE Prefabricated Metal Chimney Altering the Factory-Built Fireplace4Vent Information Venting Termination Minimum RequirementsDo not Terminate Vent Termination must exhaust above air inlet elevationNegative Pressure, Shut-Down and Electrical Power Failure Optional Battery Back-UpMt. Vernon Pellet Insert AE Avoiding Smoke and Odors Outside AirMt. Vernon Pellet Insert AE Negative Pressure Draft Mt. Vernon Pellet Insert AE Chimney and Exhaust Connection Equivalent Feet of PipeExample of 3 Elbow-Rear Vent Termination Calculation Mt. Vernon Pellet Insert AE Pipe Selection Chart Altitude in Thousands of Feet5Venting Systems Full Reline With Outside Air Horizontal305mm min. above 305mm min. below Never Install in a Sleeping Room 6Mobile Home7Appliance Set-Up Leveling SystemOutside Air Kit Instructions Mt. Vernon Pellet Insert AE Hearth Support Removal of Cast SidesMt. Vernon Pellet Insert AE Surround and Trim Set Cast Surround & Trim Set, BasicOptional Log Set Placement Instructions Rebox. Figures 23.1Rebox. Figures 23.3 7036-135G November 22 Fire Safety 8Operating InstructionsCombustible/Non-Combustible Materials Fuel Material and Fuel StorageThermostat Wall Control Automatic Setting Thermostat Wall Control Manual SettingAuto-Clean Firepot System General Operating InformationFire Characteristics and Flame Height Feed Rate Adjustment Mt. Vernon Pellet Insert AE Before Your First FireFilling the Hopper with Fuel Starting Your First FireMt. Vernon Pellet Insert AE Battery Back-up System Optional Clear SpaceMt. Vernon Pellet Insert AE Ignition Cycles Auto-Clean Cycle Insert RemovalAdditional Screen Messages Or C Mt. Vernon Pellet Insert AE Quick Start GuideWall Control for Reference 74ºF Frequently Asked Questions Issues SolutionsError Message Possible Cause Corrective ActionQuick Reference Maintenance Chart Proper Shutdown Procedure10Maintaining & Servicing Your Appliance Before Servicing Your ApplianceGeneral Maintenance and Cleaning Auto-Clean System Inspection & CleaningCleaning Ash Pan Ash Removal from FireboxLarge Clinker Cleaning Heat Exchanger, Drop Tube & Exhaust Example of a dirty heat exchangerLoosen all 6 nuts, but do not Remove Cleaning the Hopper Cleaning the GlassDoor Latch Inspection Preparing Firebox for Non-Burn SeasonBaffl e Removal Fire and Smoke RiskGlass Replacement Convection Blower ReplacementConvection Blower Replacement Cont’d Convection Blower ReplacementReference Materials Power Supply Thermocouple on Drop Tube Vacuum SwitchOverheat Sensor Snap Disc Thermocouple FirepotFeed Motor, Vacuum Switch, Exhaust Blower, Overheat Sensor Mt. Vernon Pellet Insert AE Component LocationsMt. Vernon Pellet Insert AE Exploded Drawings Part number list on following pagesStocked at Depot Stocked At Depot#38 Feed Assembly 38.5 38.6 38.4 38.3 38.2 38.1 Stocked at Depot #39 Firepot Riser Assembly #40 Auto-Clean Motor/Arm AssemblyStocked At DepotFasteners Accessories SP-MTVS-GDMt. Vernon Pellet Insert AE Mt. Vernon Pellet Insert AE Contact Information