Quadra-Fire MTVERNINSAE-PMH Mt. Vernon Pellet Insert AE Hearth Support, Removal of Cast Sides

Page 21

R

Mt. Vernon Pellet Insert (AE)

C. Hearth Support

Included in Kit: (1) bottom, (1) trim front, (2) trim sides, (2) trim extensions

Tools Needed: Phillips head screw driver, measuring tape, gloves

1.Remove contents from box and lay on protective surface to avoid scratching the paint.

2. Lay front and sides face down. Bend the tabs down toward the inside. Figure 21.1.

3.The side pieces are shipped fl at. It is must easier to fl ex the sides into a bowed position before installing.

4.Lay the cast bottom face up. Attach the 2 sides FIRST and then the front piece. Figure 21.2.

5. Turn the cast bottom right side up and attach the panel extensions. Note the alignment hole.

6.Attach the appropriate footers depending on the panels & trim set you are installing. The footers come in 2 sizes, 3 and 5 inches. Discard the footers not used.

7. Place the assembled hearth support under the insert. Lower the leveling bolts if necessary to keep the insert level.

8.Open the door and attach the hearth support to the insert. There are 9 attachment holes. Figure 21.3.

9 attachment holes - 3 on each side and 3 in the front

Figure 21.3

Bend tabs down. Shipped

flat from the factory.

Figure 21.1

D. Removal of Cast Sides

You will need to remove the cast sides in order to install the panel and trim set.

1.There is a latch on the back side of the cast side in the middle of the top opening of the cast side as indicated in Figure 21.4.

2.Place your fi ngers inside the opening and squeeze the latch. The side can now be pulled toward you and removed. Place on a protective surface so as not to damage the fi nish.

3.To replace the side, set the bottom in fi rst. Squeeze the latch in an open position. Place the cast side into posi- tion and then release the latch. The latch hooks onto a bracket to hold the side in place.

3 inch high Set Attach Trim to Insert from inside Insert.

5 inch high Set

3 in

Basic

Cast

5 in

Install Front Trim Last,

 

Corner Overlap Side

 

Trim Pieces

Attach Trim to Base

 

from underneath

Figure 21.2

Location of Latch for Removing Cast Sides

Lower the leveling bolts if necessary to keep the insert level when installing the Hearth Support.

Figure 21.4 - Shown with Cast Panel Set

November 22, 2011

7036-135G

Page 21

Image 21
Contents Hot glass will cause burns Installation and OperationLabel Location On Beaded Chain on e behind Right Side Panel Mt. Vernon Pellet Insert AETable of Contents Appliance Certifi cation Listing and Code ApprovalsMobile Home Approved Glass Specifi cationsGetting Started Design, Installation & Location ConsiderationsAppliance Location Floor SupportInspect Appliance and Components Tools And Supplies NeededPre-Use Check List Thermostat Wall Control LocationAppliance Dimensions 3Dimensions and ClearancesBuilt-in Unit Rear Vent with Outside Air Inch Clearance To Exposed Section And Face TrimMasonry and Zero Clearance Fireplaces Mt. Vernon Pellet Insert AE Built-In VerticalFloor Protection Minimum Opening for Masonry and Zero Clearance FireplacesStarter hole Mark area of floor to cut Altering the Factory-Built Fireplace Mt. Vernon Pellet Insert AE Prefabricated Metal ChimneyVenting Termination Minimum Requirements 4Vent InformationDo not Terminate Vent Termination must exhaust above air inlet elevationOptional Battery Back-Up Negative Pressure, Shut-Down and Electrical Power FailureMt. Vernon Pellet Insert AE Avoiding Smoke and Odors Outside AirMt. Vernon Pellet Insert AE Negative Pressure Draft Mt. Vernon Pellet Insert AE Chimney and Exhaust Connection Equivalent Feet of PipeExample of 3 Elbow-Rear Vent Termination Calculation Altitude in Thousands of Feet Mt. Vernon Pellet Insert AE Pipe Selection ChartFull Reline With Outside Air Horizontal 5Venting Systems305mm min. above 305mm min. below 6Mobile Home Never Install in a Sleeping Room7Appliance Set-Up Leveling SystemOutside Air Kit Instructions Removal of Cast Sides Mt. Vernon Pellet Insert AE Hearth SupportSurround & Trim Set, Basic Mt. Vernon Pellet Insert AE Surround and Trim Set CastOptional Log Set Placement Instructions Rebox. Figures 23.1Rebox. Figures 23.3 7036-135G November 22 8Operating Instructions Fire SafetyCombustible/Non-Combustible Materials Fuel Material and Fuel StorageThermostat Wall Control Manual Setting Thermostat Wall Control Automatic SettingAuto-Clean Firepot System General Operating InformationMt. Vernon Pellet Insert AE Before Your First Fire Fire Characteristics and Flame Height Feed Rate AdjustmentFilling the Hopper with Fuel Starting Your First FireClear Space Mt. Vernon Pellet Insert AE Battery Back-up System OptionalMt. Vernon Pellet Insert AE Ignition Cycles Auto-Clean Cycle Insert RemovalAdditional Screen Messages Or C Mt. Vernon Pellet Insert AE Quick Start GuideWall Control for Reference 74ºF Issues Solutions Frequently Asked QuestionsPossible Cause Corrective Action Error MessageProper Shutdown Procedure Quick Reference Maintenance Chart10Maintaining & Servicing Your Appliance Before Servicing Your ApplianceAuto-Clean System Inspection & Cleaning General Maintenance and CleaningCleaning Ash Pan Ash Removal from FireboxExample of a dirty heat exchanger Large Clinker Cleaning Heat Exchanger, Drop Tube & ExhaustLoosen all 6 nuts, but do not Remove Cleaning the Glass Cleaning the HopperDoor Latch Inspection Preparing Firebox for Non-Burn SeasonFire and Smoke Risk Baffl e RemovalConvection Blower Replacement Glass ReplacementConvection Blower Replacement Convection Blower Replacement Cont’dReference Materials Thermocouple on Drop Tube Vacuum Switch Power SupplyOverheat Sensor Snap Disc Thermocouple FirepotMt. Vernon Pellet Insert AE Component Locations Feed Motor, Vacuum Switch, Exhaust Blower, Overheat SensorPart number list on following pages Mt. Vernon Pellet Insert AE Exploded DrawingsStocked at Depot At Depot Stocked#38 Feed Assembly 38.5 38.6 38.4 38.3 38.2 38.1 #40 Auto-Clean Motor/Arm Assembly Stocked at Depot #39 Firepot Riser AssemblyAt Depot StockedFasteners SP-MTVS-GD AccessoriesMt. Vernon Pellet Insert AE Mt. Vernon Pellet Insert AE Contact Information