CLEARANCES
CLEARANCES TO COMBUSTIBLES
WARNING
Follow these instructions carefully to ensure safe installation. Failure to follow instructions exactly can create a fire hazard.
The appliance cannot be installed on a carpet, tile or other combustible material other than wood flooring. If installed on carpet or vinyl flooring, the appliance shall be installed on a metal, wood or noncombustible material panel extending full width and depth of the appliance.
71"Minimum
Minimum 4"
From Both
Side Walls
NOTE | All mantel shelves, regardless of depth, should be a mini- |
mum of 12" from top opening of fireplace. Mantel shelf | |
shall not exceed 12" maximum depth at 12" minimum | |
height from opening. | |
|
|
Maximum Depth
12" Minimum
| STUD |
| COMBUSTIBL |
| MATERIAL |
FIREPLACE | AREA |
WALL
1" | 1.5" | 2.5" |
| ||
|
| |
2.5" |
|
|
3" |
| 45° |
|
| |
4" |
|
|
Figure 5 - Clearances | Figure 5a - Mantel clearances. |
MANTEL CLEARANCES
NOTE: The combustible area above the facing must not protrude more than 3/4" from the facing. If it does, it is considered a mantel and must meet the mantel requirements listed in this manual.
10 | 54D5031 |