Monessen Hearth HBDV400, HBDV300 manual Horizontal Vent Termination Location, Minimum Distances

Page 16

VENT INSTALLATION

FOR HORIZONTAL TERMINATION

Inside Corner Detail

 

 

 

 

 

 

 

 

V

G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

A

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

C

 

 

B

B

 

 

 

 

 

B

 

 

B

 

 

 

 

I

 

 

L

V

Fixed

 

 

 

 

 

 

 

 

 

 

 

 

 

Closed

 

Opera-

Fixed

 

 

 

 

 

F

 

Operable

V

ble

Closed

 

V

 

 

 

 

 

 

 

 

 

 

 

V

 

 

V

 

A

 

 

M

 

 

B

 

 

 

B

 

V

A

 

 

 

 

 

 

 

 

 

 

 

A

J

 

 

 

 

K

G

A

V

Vent Terminal

A Air Supply Inlet

Area Where Terminals Not Permitted

Figure 12 - Horizontal Vent Termination Location

MINIMUM DISTANCES

A = Clearance above the grade, a veranda, porch, deck, or balcony [*12" (305mm) minimum]. B = Clearance to window or door that may be opened [*12" (305mm) minimum].

C = Clearance to permanently closed window [*minimum 12" (305mm) recommended to prevent condensation on window]

D = Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of two (2) feet (610mm) from the centerline of the terminal [18" (457mm) minimum].

E = Clearance to unventilated soffits [12" (305mm) minimum]. Clearance to vinyl soffit [30" (762mm)]. F = Clearance to an outside corner. See Figure 12.

G = Clearance to an inside corner. See Figure 12.

H= *Not to be installed above a gas meter/regulator assembly within three (3) feet (914mm) horizontally from the centerline of the regulator.

I= Clearance to service regulator vent outlet [*3' (914mm) minimum].

J= Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance [*12" (305mm)minimum].

K= Clearance to a mechanical air supply inlet [*6' (1829mm) minimum].

L= Clearance above a paved sidewalk or paved driveway located on public property [**7' (2133mm) minimum].

M= Clearance under veranda, porch, deck, or balcony. See Figure 13, page 17. [For Canada *12" (305mm) minimum***].

*As specified in CAN/CGA B149 Installation Codes. Note: Local codes or regulations may require different clearances.

**A vent must not terminate directly above a sidewalk or paved driveway, which is located between two single-family dwellings and serves both dwellings.

WARNING

Always maintain minimum clearances around vent systems. The minimum clearances to combustibles for horizontal vent pipe are 3" at the top and 1" at the sides and bottom of the vent system until the pipe penetrates the nearest vertical wall (1" required). A 1" minimum clearance all around the pipe must be maintained at outside wall and on vertical runs. Do not pack the open air spaces with insulation or other materials. This could cause high temperatures and may present a fire hazard.

16

54D5031

Image 16
Contents Models What to do if YOU Smell GASContents Installer Important Safety InformationOwner Never connect unit to private Non-utility gas wells. ThisGas is commonly known as Wellhead gasProduct Features and Code Approval Product SpecificationsCode Approval Listed Vented GAS Fireplace HeaterPRE-INSTALLATION Information High ElevationsOrifice SIZES, Pressures and BTUs Before YOU StartFraming Dimensions Fireplace FramingFireplace Dimensions Fireplace DimensionsFireplace Location Locating Gas FireplaceClearances to Combustibles ClearancesMantel Clearances Insulation Board Securing Fireplace to Floor or FramingInstallation Precautions Installation InformationFinishing Material Vent Installation Combustible Clearances for Vent PipeOptional TOP Vent Application After conversion to top ventConfiguration the 4 100mm flue pipe Should be concentric within the 65/8Installation Planning Installing a Vent System in AN Outside ChaseFor Horizontal Termination For Vertical TerminationHorizontal Vent Termination Location Minimum DistancesHOW to USE the Vent Graph FeetVenting Installation Rear Through the Wall ApplicationsRear Wall Vent Installation Do not recess vent terminationInto any wall. This will cause a fire hazardHorizontal Termination Configurations Maximum Three 3 90 Elbows Per InstallationHorizontal Termination Configuration Horizontal Run ReductionBelow Grade Installations Below Grade InstallationVertical THROUGH-THE-ROOF Applications Support Straps for Horizontal RunsInstallation for Vertical Termination Flat Ceiling InstallationMinimum chimney clearance Flex Vent Installation Start the flexible vent as followsTypical pipe connection Installing GAS Piping to Fireplace / Burner System Location Fireplace InstallationCheck GAS Type Gas Connection Checking GAS Pressure and Electrical Installation Do not use open flame to checkElectrical Installation Remote Wall Mounted SwitchRemote Wall Switch Optional DC Remote SystemsBrick Installation Glass Removal & Brick InstallationGlass Frame Removal Final Installation Placement of Lava ROCK, Rock Wool and LogsLog #3 Log #2 Installing Universal Andirons Placement of Log 7 HBDV400 onlyLeak Testing Operating Instructions MillivoltWhat to do if YOU Smell GAS Initial LightingApproved Leak Testing Method Lighting the Burner Main Burner SwitchPilot Position Cleaning and Maintenance BURNER, Pilot and Control CompartmentPilot Flame BurnerVent System Glass DoorLogs Rock WoolSymptom Possible Cause Action Standing Pilot IgnitionTroubleshooting Replacement Parts Fireplace ComponentsCC=Cottage Clay CR=Cottage Red Millivolt Engine Millivolt Components Vent ComponentsVent Components Refer to illustrations on previousLogs Special Requirements Special Requirements 54D5031 54D5031 54D5031 Five Year Warranty Lifetime WarrantyBasic Warranty