Monessen Hearth HBDV400, HBDV300 manual CC=Cottage Clay CR=Cottage Red

Page 44

REPLACEMENT PARTS

FIREPLACE COMPONENTS

Item

Description

Qty

HBDV300

HBDV400

Standard Features

 

 

 

 

 

 

 

 

1

Junction Box Assembly

1

26D2128K

26D2128K

2

Black Louver (each)

1

54D0246

26D0695

3

Glass Frame Assembly

1

54D5113

54D5034

11

Andiron Kit (contains 2)

1

UAI9

UAI9

Accessories/Field Installed Options

 

 

 

2

Brass Louver Assembly (upper and lower)

1

L30BR

L32BR

2

Pewter Louver Assembly (upper and lower)

1

L30PW

L32PW

4

Thermostat Sensor

1

26D2870

26D2870

5

Standard Firebrick Center CC

1

26D7069

26D7077

6

Standard Firebrick Right CC

1

26D7068

26D7076

7

Standard Firebrick Left CC

1

26D7068

26D7075

5

Standard Firebrick Center CR

1

26D7097

26D7105

6

Standard Firebrick Right CR

1

26D7096

26D7104

7

Standard Firebrick Left CR

1

26D7096

26D7103

8

Cottage Clay Firebrick Walls

1

FB300CCW

FB400CCW

8

Cottage Red Firebrick Walls

1

FB300CRW

FB400CRW

9

Brass Curved Design Trim

1

BRTK30C

BRTK32C

9

Pewter Curved Design Trim

1

PWTK30C

PWTK32C

9

Black Curved Design Trim

1

BLTK30C

BLTK32C

9

Black Trim

1

BLMTK30

BLMTK32

9

Pewter Trim

1

PWMTK30

PWMTK32

9

Brass Trim

1

BRMTK30

BRMTK32

10

Blower Motor

1

26D0748

26D0748

N/S

T-stat Blower with Speed Control

1

BLOT

BLOT

CC=Cottage Clay

CR=Cottage Red

44

54D5031

Image 44
Contents Models What to do if YOU Smell GASContents Owner Important Safety InformationInstaller Never connect unit to private Non-utility gas wells. ThisGas is commonly known as Wellhead gasProduct Features and Code Approval Product SpecificationsCode Approval Listed Vented GAS Fireplace HeaterPRE-INSTALLATION Information High ElevationsOrifice SIZES, Pressures and BTUs Before YOU StartFraming Dimensions Fireplace FramingFireplace Dimensions Fireplace DimensionsFireplace Location Locating Gas FireplaceMantel Clearances ClearancesClearances to Combustibles Insulation Board Securing Fireplace to Floor or FramingFinishing Material Installation InformationInstallation Precautions Vent Installation Combustible Clearances for Vent PipeOptional TOP Vent Application After conversion to top ventConfiguration the 4 100mm flue pipe Should be concentric within the 65/8Installation Planning Installing a Vent System in AN Outside ChaseFor Horizontal Termination For Vertical TerminationHorizontal Vent Termination Location Minimum DistancesHOW to USE the Vent Graph FeetVenting Installation Rear Through the Wall ApplicationsRear Wall Vent Installation Do not recess vent terminationInto any wall. This will cause a fire hazardHorizontal Termination Configurations Maximum Three 3 90 Elbows Per InstallationHorizontal Termination Configuration Horizontal Run ReductionBelow Grade Installations Below Grade InstallationVertical THROUGH-THE-ROOF Applications Support Straps for Horizontal RunsInstallation for Vertical Termination Flat Ceiling InstallationMinimum chimney clearance Flex Vent Installation Start the flexible vent as followsTypical pipe connection Check GAS Type Fireplace InstallationInstalling GAS Piping to Fireplace / Burner System Location Gas Connection Checking GAS Pressure and Electrical Installation Do not use open flame to checkElectrical Installation Remote Wall Mounted SwitchRemote Wall Switch Optional DC Remote SystemsGlass Frame Removal Glass Removal & Brick InstallationBrick Installation Final Installation Placement of Lava ROCK, Rock Wool and LogsLog #3 Log #2 Installing Universal Andirons Placement of Log 7 HBDV400 onlyLeak Testing Operating Instructions MillivoltWhat to do if YOU Smell GAS Initial LightingApproved Leak Testing Method Pilot Position Main Burner SwitchLighting the Burner Cleaning and Maintenance BURNER, Pilot and Control CompartmentPilot Flame BurnerVent System Glass DoorLogs Rock WoolSymptom Possible Cause Action Standing Pilot IgnitionTroubleshooting Replacement Parts Fireplace ComponentsCC=Cottage Clay CR=Cottage Red Millivolt Engine Millivolt Components Vent ComponentsVent Components Refer to illustrations on previousLogs Special Requirements Special Requirements 54D5031 54D5031 54D5031 Basic Warranty Lifetime WarrantyFive Year Warranty