CLEANING AND MAINTENANCE

VENT SYSTEM

The fireplace and venting system should be inspected before initial use and at least annually by a qualified field service person. Inspect the external vent cap on a regular basis to make sure that no debris is interfering with the airflow. Inspect entire venting system to ensure proper function.

GLASS DOOR

Thoroughly clean the inside of the glass door after using the fireplace for ten hours. Periodically clean the glass door as necessary.

When cleaning the glass, remember:

Do not remove the glass when hot. Allow glass to cool before removal.

NEVER use abrasive materials.

Keep children and pets a safe distance away.

Never operate the fireplace without the glass door properly secured.

Never operate the fireplace if the glass is broken.

Replace any glass that is chipped, cracked, or broken. Replacement glass door assemblies MUST be supplied by the fireplace manufacturer – No substitute materials may be used.

Handle glass door with care to avoid striking or scratching it on hard objects.

To clean glass door, follow “Glass Removal” procedure outlined in the Final Installation section. Film deposit on the inside of the glass should be cleaned off using a nontoxic, non-corrosive, non-abrasive, mild-cleaning solution. Simply apply an adequate amount to the glass and wipe off with a damp cloth. After all maintenance has been completed, re-install glass door.

LOGS

Leave logs installed in the fireplace for cleaning. Vacuum surface of the logs with a brush attachment. If logs must be removed for cleaning, handle carefully by holding gently at each end. Gloves are recommended to prevent skin irritation from ceramic fibers. If skin becomes irritated, wash gently with soap and water. Vacuum surface of logs with brush attachment or brush logs with a soft bristle brush (i.e. clean, dry paintbrush). To place logs back in the fireplace, see “Log Placement” found in the Final Installation section.

NOTE: Do not use fluids to clean ceramic fiber logs.

ROCK WOOL

Replace or add rock wool as required following installation instructions in the Final Installation section of this manual.

40

54D5031

Image 40
Contents Models What to do if YOU Smell GASContents Installer Important Safety InformationOwner Never connect unit to private Non-utility gas wells. ThisGas is commonly known as Wellhead gasProduct Features and Code Approval Product SpecificationsCode Approval Listed Vented GAS Fireplace HeaterPRE-INSTALLATION Information High ElevationsOrifice SIZES, Pressures and BTUs Before YOU StartFraming Dimensions Fireplace FramingFireplace Dimensions Fireplace DimensionsFireplace Location Locating Gas FireplaceClearances to Combustibles ClearancesMantel Clearances Insulation Board Securing Fireplace to Floor or FramingInstallation Precautions Installation InformationFinishing Material Vent Installation Combustible Clearances for Vent PipeOptional TOP Vent Application After conversion to top ventConfiguration the 4 100mm flue pipe Should be concentric within the 65/8Installation Planning Installing a Vent System in AN Outside ChaseFor Horizontal Termination For Vertical TerminationHorizontal Vent Termination Location Minimum DistancesHOW to USE the Vent Graph FeetVenting Installation Rear Through the Wall ApplicationsRear Wall Vent Installation Do not recess vent terminationInto any wall. This will cause a fire hazardHorizontal Termination Configurations Maximum Three 3 90 Elbows Per InstallationHorizontal Termination Configuration Horizontal Run ReductionBelow Grade Installations Below Grade InstallationVertical THROUGH-THE-ROOF Applications Support Straps for Horizontal RunsInstallation for Vertical Termination Flat Ceiling InstallationMinimum chimney clearance Flex Vent Installation Start the flexible vent as followsTypical pipe connection Installing GAS Piping to Fireplace / Burner System Location Fireplace InstallationCheck GAS Type Gas Connection Checking GAS Pressure and Electrical Installation Do not use open flame to checkElectrical Installation Remote Wall Mounted SwitchRemote Wall Switch Optional DC Remote SystemsBrick Installation Glass Removal & Brick InstallationGlass Frame Removal Final Installation Placement of Lava ROCK, Rock Wool and LogsLog #3 Log #2 Installing Universal Andirons Placement of Log 7 HBDV400 onlyLeak Testing Operating Instructions MillivoltWhat to do if YOU Smell GAS Initial LightingApproved Leak Testing Method Lighting the Burner Main Burner SwitchPilot Position Cleaning and Maintenance BURNER, Pilot and Control CompartmentPilot Flame BurnerVent System Glass DoorLogs Rock WoolSymptom Possible Cause Action Standing Pilot IgnitionTroubleshooting Replacement Parts Fireplace ComponentsCC=Cottage Clay CR=Cottage Red Millivolt Engine Millivolt Components Vent ComponentsVent Components Refer to illustrations on previousLogs Special Requirements Special Requirements 54D5031 54D5031 54D5031 Five Year Warranty Lifetime WarrantyBasic Warranty