Monessen Hearth CDV7 Electronic Pilot Ignition Wiring, Optional Fan/Blower Systems, Malfunction

Page 31

 

 

 

Electrical installation

CDVSC7 & CDV7 Series Gas Fireplace

 

 

 

Electronic Pilot Ignition Wiring

WARNING

Do not connect 110-120 VAC to the

 

 

Remote Wall Switch. The appliance will

 

malfunction.

 

 

Pilot Assembly

To Junction Box

Sense

Spark

 

Ignition Module (Synetek)

#1 #2 #3 #4 #5 #6 7#

RED #2

Electronic Valve

 

 

HI

WHITE #3

EV1

EV2

RED #2

GRAY #7

 

 

GREEN

 

WHITE

BLACK

 

MAGENTA #5

BLACK

 

WHITE

 

 

 

 

Primary - 120V

 

#6

 

BLACK #4

GREEN

Transformer

Secondary

24V

YELLOW

 

BLUE

15’ Wall Switch Wire

BLACK

WHITE

Figure 45 -

Remote Wall Switch Wiring Diagram

Switch

RS

OFF

ON

BLUE #1

YELLOW

Optional Fan/Blower Systems

The junction box for the fan/blower systems has been factory installed. This system requires that 110- 120 VAC to be wired to the factory installed junction box before the fireplace is permanently installed. Figure 46

Receptacle

120V AC

Junction Box

 

 

 

Black

 

 

 

 

Green

 

 

 

 

Thermostatic

 

 

Speed Control

 

Switch

FP2296

Black

White

Black

Black

 

Thermostatic

Figure 46 -Control Blower

Blower Wiring Diagram

69D3011

31

Image 31
Contents Consumer Retain this manual for future refer- ence CdvtCdvr Do not try to light any applianceOperating Instructions Electronic Ignition Pre-Installation InformationElectrical Wiring Check Gas Pressure Signature Command System36Installer Important Safety InformationOwner As wellhead gas Code ApprovalNever connect unit to private non-utility Gas wells. This gas is commonly knownProduct Specifications Product featuresGAS pressures GAS Specifications & Orifice Size Cdvr SeriesGAS Specifications & Orifice Size Cdvt Series High ElevationsFraming Dimensions Fireplace dimensions & FramingCDVR33V,E7 CDVT36 V,E,SC7 CDVT42 V,E,SC7 CDVT47 V,E,SC7 CDVT33V,E,SC7Cold Climate Insulation Fireplace Location Clearances to combustibles ClearancesMantel clearances Finishing Material Installation precautions Venting Installation InformationGeneral Venting General Venting Information Termination Location Canadian Installations1 US Installations2Canadian Installations USA InstallationsTermination Clearances Twist Lock Pipes Rear Vent Installation onlyRefer to Page 24 for snorkel requirements How to Use the Vent GraphVent Pipe Clearances Venting installationRear Wall Vent Application Rear Wall Vent Installation Twist Lock PipeStep Venting System Rear Wall Vent Installations Flex Vent PipeTop vent Sidewall Application Since it is very im Portant ThatMaximum number of 90 elbows per side wall Always install horizontal venting on a level plane Vertical Sidewall Installation Twist Lock PipeVertical Sidewall installation flex vent pipe Vertical THROUGH-THE-ROOF APPLICA- Tion Below Grade InstallationDo not back fill around snorkel Vertical THROUGH-THE-ROOF Installation Minimum Chimney Clearance Install gas piping to fireplace / burner system location Fireplace installationCheck gas type Natural Gas Do not use open flame to check for gas Electrical WiringLeaks Remote Wall Switch Electrical installationRemote Wall mounted Switch Do not connect wall switch to 110Do not connect 110-120 VAC to Electronic Pilot Ignition WiringRemote Wall Switch. The appliance will Optional Fan/Blower SystemsNever use an open flame to check for gas leak Leak testingMillivolt Operating Instructions Initial lightingNever check for gas leak with open flame Approved leak testing methodLighting the burner Main burner switchPilot position Injury or loss of life Causing property damage, personalIf you do not follow these instruction Exactly, a fire or explosion may resultOr performing service. All wiring shall be Optional Accessory RequirementsElectrician. Main power must be off when Connecting to main electrical power supplyWall Switch Installation Electrical InstallationJunction BOX Wiring Command Center Wall InstallationElectrical Installation Optional FAN Blower Systems Blotsc Signature Command BlowerFK-12 Manual Blower Blot Automatic Thermostat BlowerOn next OPERATing Instructions Command CenterBattery Installation FeaturesCommand Center Key Combinations for System Settings System CONFIGURATION/SETUPFunction Operation Default Setting Function Operation Command Center OperationsSelf Diagnostics Chart FUNCTIONS/OPERATIONGlass Frame Removal Rock wool placementLava rock and ember placement Log placementBurner, Pilot and Control Compart- ment Cleaning and maintenanceRock wool Vent SystemGlass Door LogsStanding Pilot Ignition TroubleshootingPoSSIBLE Cause CDVSC7 & CDV7 Series Gas Fireplace YeS Electronic IgnitionOperationfault Diagnosis Action Signature Command SystemFirebox components Replacement partsCDVR33 CDVT33 CDVR36 CDVT36 CDVR42 CDVT42 CDVR47 CDVT47 Standing Pilot Millivolt control LP to Natural Gas Replacement PartsAccessories Description Qty Part Number Fuel Conversion Kits Millivolt Natural Gas to LPElectronic Ignition CDVSC7 & CDV7 Series Gas Fireplace13,14,15,16,17 CDVR33NSC7 CDVR33SC7 Description Model Number Vertical Venting7TBRHTK Horizontal VentingCDVSC7 & CDV7 Series Gas Fireplace CDVSC7 & CDV7 Series Gas Fireplace Carbon Monoxide Detector Requirements If Warranty Service is Needed Lifetime WarrantyFive Year Warranty Basic WarrantyModel EnerGuide Ratings Fireplace Efficiency % Mhsc