Monessen Hearth CDV7 manual Mhsc, Model EnerGuide Ratings Fireplace Efficiency %

Page 68

Based on CSA P.4.1-09

Efficiency Ratings

Model

EnerGuide Ratings

 

Fireplace Efficiency (%)

CDVR33NV7

62.6

CDVR33PV7

64.3

CDVR33NE7

66.8

CDVR33PE7

68.1

CDVR33NSC7

57.6

CDVR33PSC7

64.3

CDVR36NV7

47.7

CDVR36PV7

53.6

CDVR36NE7

49.7

CDVR36PE7

56.1

CDVR36NSC7

49.7

CDVR36PSC7

56.1

CDVR42NV7

66.8

CDVR42PV7

68.7

CDVR42NE7

71.0

CDVR42PE7

72.3

CDVR42NSC7

71.0

CDVR42PSC7

72.3

CDVR47NV7

65.6

CDVR47PV7

67.1

CDVR47NE7

69.6

CDVR47PE7

70.6

CDVR47NSC7

69.6

CDVR47PSC7

70.6

 

 

Efficiency Ratings

 

 

Model

EnerGuide Ratings

 

Fireplace Efficiency (%)

CDVT33NV7

45.9

CDVT33PV7

53.0

CDVT33NE7

47.6

CDVT33PE7

55.4

CDVT33NSC7

47.6

CDVT33PSC7

55.4

CDVT36NV7

47.7

CDVT36PV7

53.6

CDVT36NE7

49.7

CDVT36PE7

56.1

CDVT36NSC7

47.6

CDVT36PSC7

55.4

CDVT42NV7

56.3

CDVT42PV7

64.3

CDVT42NE7

59.1

CDVT42PE7

67.6

CDVT42NSC7

59.1

CDVT42PSC7

67.6

CDVT47NV7

54.2

CDVT47PV7

62.4

CDVT47NE7

56.6

CDVT47PE7

65.7

CDVT47NSC7

56.6

CDVT47PSC7

65.7

MHSC

149 Cleveland Drive • Paris, Kentucky 40361

www.mhsc.com

Image 68
Contents Cdvt CdvrDo not try to light any appliance Consumer Retain this manual for future refer- encePre-Installation Information Electrical WiringCheck Gas Pressure Signature Command System36 Operating Instructions Electronic IgnitionOwner Important Safety InformationInstaller Code Approval Never connect unit to private non-utilityGas wells. This gas is commonly known As wellhead gasProduct features Product SpecificationsGAS Specifications & Orifice Size Cdvr Series GAS Specifications & Orifice Size Cdvt SeriesHigh Elevations GAS pressuresCDVR33V,E7 Fireplace dimensions & FramingFraming Dimensions CDVT33V,E,SC7 CDVT36 V,E,SC7 CDVT42 V,E,SC7 CDVT47 V,E,SC7Cold Climate Insulation Fireplace Location Mantel clearances ClearancesClearances to combustibles Finishing Material General Venting Venting Installation InformationInstallation precautions Canadian Installations1 US Installations2 General Venting Information Termination LocationTermination Clearances USA InstallationsCanadian Installations Rear Vent Installation only Twist Lock PipesHow to Use the Vent Graph Refer to Page 24 for snorkel requirementsVenting installation Vent Pipe ClearancesStep Rear Wall Vent Installation Twist Lock PipeRear Wall Vent Application Rear Wall Vent Installations Flex Vent Pipe Top vent Sidewall ApplicationSince it is very im Portant That Venting SystemMaximum number of 90 elbows per side wall Vertical Sidewall Installation Twist Lock Pipe Always install horizontal venting on a level planeVertical Sidewall installation flex vent pipe Do not back fill around snorkel Below Grade InstallationVertical THROUGH-THE-ROOF APPLICA- Tion Vertical THROUGH-THE-ROOF Installation Minimum Chimney Clearance Check gas type Fireplace installationInstall gas piping to fireplace / burner system location Natural Gas Leaks Electrical WiringDo not use open flame to check for gas Electrical installation Remote Wall mounted SwitchDo not connect wall switch to 110 Remote Wall SwitchElectronic Pilot Ignition Wiring Remote Wall Switch. The appliance willOptional Fan/Blower Systems Do not connect 110-120 VAC toLeak testing Millivolt Operating InstructionsInitial lighting Never use an open flame to check for gas leakApproved leak testing method Never check for gas leak with open flamePilot position Main burner switchLighting the burner Causing property damage, personal If you do not follow these instructionExactly, a fire or explosion may result Injury or loss of lifeOptional Accessory Requirements Electrician. Main power must be off whenConnecting to main electrical power supply Or performing service. All wiring shall beElectrical Installation Junction BOX WiringCommand Center Wall Installation Wall Switch InstallationElectrical Installation Blotsc Signature Command Blower Optional FAN Blower SystemsBlot Automatic Thermostat Blower FK-12 Manual BlowerOn next Command Center OPERATing InstructionsCommand Center FeaturesBattery Installation Function Operation Default Setting System CONFIGURATION/SETUPKey Combinations for System Settings Command Center Operations Self Diagnostics ChartFUNCTIONS/OPERATION Function OperationRock wool placement Glass Frame RemovalLog placement Lava rock and ember placementCleaning and maintenance Burner, Pilot and Control Compart- mentVent System Glass DoorLogs Rock woolPoSSIBLE Cause TroubleshootingStanding Pilot Ignition CDVSC7 & CDV7 Series Gas Fireplace Electronic Ignition YeSSignature Command System Operationfault Diagnosis ActionReplacement parts Firebox componentsCDVR33 CDVT33 CDVR36 CDVT36 CDVR42 CDVT42 CDVR47 CDVT47 Standing Pilot Millivolt control Replacement Parts Accessories Description Qty Part NumberFuel Conversion Kits Millivolt Natural Gas to LP LP to Natural GasCDVSC7 & CDV7 Series Gas Fireplace Electronic Ignition13,14,15,16,17 CDVR33NSC7 CDVR33SC7 Vertical Venting Description Model NumberHorizontal Venting 7TBRHTKCDVSC7 & CDV7 Series Gas Fireplace CDVSC7 & CDV7 Series Gas Fireplace Carbon Monoxide Detector Requirements Lifetime Warranty Five Year WarrantyBasic Warranty If Warranty Service is NeededMhsc Model EnerGuide Ratings Fireplace Efficiency %