Monessen Hearth CDV7 manual Troubleshooting, Standing Pilot Ignition, PoSSIBLE Cause

Page 50

CDVSC7 & CDV7 Series Gas Fireplace

troubleshooting

Standing Pilot Ignition

 

SYMPTOM

poSSIBLE CAUSE

ACTION

 

 

 

 

1.

Spark ignitor will

A. Wire disconnected.

A. Open door and check to make sure wire is connected to

 

not light pilot after

 

ignitor.

 

repeated triggering of

B. Defective ignitor.

B. Check for spark at electrode and pilot. If no spark and

 

piezo.

 

electrode wire is properly connected, replace pilot

 

 

 

assembly.

 

 

C. No gas or low gas pres-

C. Check remote/manual shut off valve from fireplace. Low

 

 

sure.

pressure can be caused by bent lines, restricted lines,

 

 

 

low pressure line pressure. Consult with plumber or gas

 

 

 

supplier.

 

 

D. No Propane/LPG in tank

D. Check Propane/LPG tank. Refill tank.

 

 

 

2. Pilot will not stay lit

A. Defective thermocouple

A. Check that thermocouple flame impinges on thermo-

 

after carefully follow-

 

couple. Clean and/or adjust pilot for maximum flame

 

ing lighting instruc-

 

impingement. Ensure that the thermocouple connection

 

tions.

 

at the gas valve is fully inserted and tight.

 

 

 

Disconnect the thermocouple from the valve, place one

 

 

 

millivolt lead wire on the tip of the thermocouple and the

 

 

 

other meter lead wire on the thermocouple copper lead.

 

 

 

Start the pilot and hold the valve knob in. If the millivolt

 

 

 

reading is less than 15 mV, replace pilot assembly.

 

 

 

B. If thermocouple is producing more than 15 mV, replace

 

 

B. Defective valve

faulty valve.

 

 

 

 

3.

Pilot burning, valve

 

A. Check switch and wire for proper connection. Place

A. Defective switch, wall

jumper wires across terminals of switch. If burner comes

 

knob turned to “ON”,

switch, remote control or

on, replace defective switch.If the switch is OK, repeat

 

switch is turned to

wire

the same procedure on remote control If burner comes

 

“ON” or “RS”, but

 

on, replace remote control.

 

burner will not ignite.

 

Place jumper wire across wire at gas valves (terminals

 

 

 

marked TH and TP/TH). If burner comes on, wires are

 

 

 

faulty or connections are bad. Replace wire.

 

 

 

B. If pilot flame is not close enough to the thermopile, adjust

 

 

B. Pilot flame too small

pilot flame.

 

 

 

C. Check thermopile wire connections to make sure all

 

 

C. Defective or malfunction-

are tight and that the thermopile is fully inserted into

 

 

ing thermopile

pilot assembly. Check thermopile with a millivolt meter.

 

 

 

Connect leads to TP and TP/TH terminals on the control

 

 

 

valve. If meter reading is below 325 mV, replace pilot

 

 

 

assembly.

 

 

 

D. Turn valve knob to “On” and switch to “ON.” Take a read-

 

 

D. Defective valve

ing at the thermopile leads (TP & TP/TH) on the valve.

 

 

 

If the meter reads greater than 175 mV and the burner

does not light, replace defective valve.

50

69D3011

Image 50
Contents Do not try to light any appliance CdvtCdvr Consumer Retain this manual for future refer- enceCheck Gas Pressure Signature Command System36 Pre-Installation InformationElectrical Wiring Operating Instructions Electronic IgnitionOwner Important Safety InformationInstaller Gas wells. This gas is commonly known Code ApprovalNever connect unit to private non-utility As wellhead gasProduct features Product SpecificationsHigh Elevations GAS Specifications & Orifice Size Cdvr SeriesGAS Specifications & Orifice Size Cdvt Series GAS pressuresCDVR33V,E7 Fireplace dimensions & FramingFraming Dimensions CDVT33V,E,SC7 CDVT36 V,E,SC7 CDVT42 V,E,SC7 CDVT47 V,E,SC7Cold Climate Insulation Fireplace Location Mantel clearances ClearancesClearances to combustibles Finishing Material General Venting Venting Installation InformationInstallation precautions Canadian Installations1 US Installations2 General Venting Information Termination LocationTermination Clearances USA InstallationsCanadian Installations Rear Vent Installation only Twist Lock PipesHow to Use the Vent Graph Refer to Page 24 for snorkel requirementsVenting installation Vent Pipe ClearancesStep Rear Wall Vent Installation Twist Lock PipeRear Wall Vent Application Since it is very im Portant That Rear Wall Vent Installations Flex Vent PipeTop vent Sidewall Application Venting SystemMaximum number of 90 elbows per side wall Vertical Sidewall Installation Twist Lock Pipe Always install horizontal venting on a level planeVertical Sidewall installation flex vent pipe Do not back fill around snorkel Below Grade InstallationVertical THROUGH-THE-ROOF APPLICA- Tion Vertical THROUGH-THE-ROOF Installation Minimum Chimney Clearance Check gas type Fireplace installationInstall gas piping to fireplace / burner system location Natural Gas Leaks Electrical WiringDo not use open flame to check for gas Do not connect wall switch to 110 Electrical installationRemote Wall mounted Switch Remote Wall SwitchOptional Fan/Blower Systems Electronic Pilot Ignition WiringRemote Wall Switch. The appliance will Do not connect 110-120 VAC toInitial lighting Leak testingMillivolt Operating Instructions Never use an open flame to check for gas leakApproved leak testing method Never check for gas leak with open flamePilot position Main burner switchLighting the burner Exactly, a fire or explosion may result Causing property damage, personalIf you do not follow these instruction Injury or loss of lifeConnecting to main electrical power supply Optional Accessory RequirementsElectrician. Main power must be off when Or performing service. All wiring shall beCommand Center Wall Installation Electrical InstallationJunction BOX Wiring Wall Switch InstallationElectrical Installation Blotsc Signature Command Blower Optional FAN Blower SystemsBlot Automatic Thermostat Blower FK-12 Manual BlowerOn next Command Center OPERATing InstructionsCommand Center FeaturesBattery Installation Function Operation Default Setting System CONFIGURATION/SETUPKey Combinations for System Settings FUNCTIONS/OPERATION Command Center OperationsSelf Diagnostics Chart Function OperationRock wool placement Glass Frame RemovalLog placement Lava rock and ember placementCleaning and maintenance Burner, Pilot and Control Compart- mentLogs Vent SystemGlass Door Rock woolPoSSIBLE Cause TroubleshootingStanding Pilot Ignition CDVSC7 & CDV7 Series Gas Fireplace Electronic Ignition YeSSignature Command System Operationfault Diagnosis ActionReplacement parts Firebox componentsCDVR33 CDVT33 CDVR36 CDVT36 CDVR42 CDVT42 CDVR47 CDVT47 Standing Pilot Millivolt control Fuel Conversion Kits Millivolt Natural Gas to LP Replacement PartsAccessories Description Qty Part Number LP to Natural GasCDVSC7 & CDV7 Series Gas Fireplace Electronic Ignition13,14,15,16,17 CDVR33NSC7 CDVR33SC7 Vertical Venting Description Model NumberHorizontal Venting 7TBRHTKCDVSC7 & CDV7 Series Gas Fireplace CDVSC7 & CDV7 Series Gas Fireplace Carbon Monoxide Detector Requirements Basic Warranty Lifetime WarrantyFive Year Warranty If Warranty Service is NeededMhsc Model EnerGuide Ratings Fireplace Efficiency %