Monessen Hearth CDV7 manual Vertical Venting, Description Model Number

Page 62

CDVSC7 & CDV7 Series Gas Fireplace

VENTING COMPONENTS

VERTICAL VENTING

Vertical Vent Termination Kits

Twist Lock Pipe

 

 

 

ve

 

 

scope9

d

 

Components

584F

 

sections twis

V enting

9

djt

 

 

 

 

 

Twist Lock Elbows

Description

Model Number

Vertical Vent Termination w/ Storm Collar

7TDVSKV

(flashing NOT included)

 

Vertical Vent Termination w/ Storm Collar - 8 pack

7TDVSKV/8

(flashing NOT included)

 

Vertical Vent Termination w/ 1/12 - 6/12 Flashing, Storm

7TDVSKVA*

Collar and Ceiling Support Kit

 

Vertical Vent Termination w/ 6/12 - 12/12 Flashing,

7TDVSKVB*

Storm Collar and Ceiling Support Kit

 

Vertical Vent Termination w/ Flat Flashing, Storm Collar

7TDVSKVF*

and Ceiling Support Kit

 

0" Rigid Pipe - single pack

7TDVP20

30" Flex Pipe - single pack

7FDVP30

12" - 18" Adjustable Vent Length

7TDVP1218

35" - 64" Adjustable Vent Length

7TDVP3564

8" Vent Pipe - 4 pack

7TDVP8/4

12" Vent Pipe - 4 pack

7TDVP12/4

4" Vent Pipe - 4 pack

7TDVP24/4

36" Vent Pipe

7TDVP36

36" Vent Pipe - 30 pack

7TDVP36/30

48" Vent Pipe

7TDVP48

48" Vent Pipe - 30 pack

7TDVP48/30

45° Elbow for Vertical/Horizontal Offset

7TDV45

45° Elbow for Vertical Offsets - 8 pack

7TDV45/8

90° Elbow for Vertical/Horizontal Offset

7TDV90

90° Elbow for Vertical/Horizontal Offset - 8 pack

7TDV90/8

Shields and Supports

1" Firestop

7DV1FS

1" Attic Insulation Shield

7DV1AIS

Combination Horizontal Offset/Roof Support

7DVCS

62

69D3011

Image 62
Contents Do not try to light any appliance CdvtCdvr Consumer Retain this manual for future refer- enceCheck Gas Pressure Signature Command System36 Pre-Installation InformationElectrical Wiring Operating Instructions Electronic IgnitionOwner Important Safety InformationInstaller Gas wells. This gas is commonly known Code ApprovalNever connect unit to private non-utility As wellhead gasProduct features Product SpecificationsHigh Elevations GAS Specifications & Orifice Size Cdvr SeriesGAS Specifications & Orifice Size Cdvt Series GAS pressuresCDVR33V,E7 Fireplace dimensions & FramingFraming Dimensions CDVT33V,E,SC7 CDVT36 V,E,SC7 CDVT42 V,E,SC7 CDVT47 V,E,SC7Cold Climate Insulation Fireplace Location Mantel clearances ClearancesClearances to combustibles Finishing Material General Venting Venting Installation InformationInstallation precautions Canadian Installations1 US Installations2 General Venting Information Termination LocationTermination Clearances USA InstallationsCanadian Installations Rear Vent Installation only Twist Lock PipesHow to Use the Vent Graph Refer to Page 24 for snorkel requirementsVenting installation Vent Pipe ClearancesStep Rear Wall Vent Installation Twist Lock PipeRear Wall Vent Application Since it is very im Portant That Rear Wall Vent Installations Flex Vent PipeTop vent Sidewall Application Venting SystemMaximum number of 90 elbows per side wall Vertical Sidewall Installation Twist Lock Pipe Always install horizontal venting on a level planeVertical Sidewall installation flex vent pipe Do not back fill around snorkel Below Grade InstallationVertical THROUGH-THE-ROOF APPLICA- Tion Vertical THROUGH-THE-ROOF Installation Minimum Chimney Clearance Check gas type Fireplace installationInstall gas piping to fireplace / burner system location Natural Gas Leaks Electrical WiringDo not use open flame to check for gas Do not connect wall switch to 110 Electrical installationRemote Wall mounted Switch Remote Wall SwitchOptional Fan/Blower Systems Electronic Pilot Ignition WiringRemote Wall Switch. The appliance will Do not connect 110-120 VAC toInitial lighting Leak testingMillivolt Operating Instructions Never use an open flame to check for gas leakApproved leak testing method Never check for gas leak with open flamePilot position Main burner switchLighting the burner Exactly, a fire or explosion may result Causing property damage, personalIf you do not follow these instruction Injury or loss of lifeConnecting to main electrical power supply Optional Accessory RequirementsElectrician. Main power must be off when Or performing service. All wiring shall beCommand Center Wall Installation Electrical InstallationJunction BOX Wiring Wall Switch InstallationElectrical Installation Blotsc Signature Command Blower Optional FAN Blower SystemsBlot Automatic Thermostat Blower FK-12 Manual BlowerOn next Command Center OPERATing InstructionsCommand Center FeaturesBattery Installation Function Operation Default Setting System CONFIGURATION/SETUPKey Combinations for System Settings FUNCTIONS/OPERATION Command Center OperationsSelf Diagnostics Chart Function OperationRock wool placement Glass Frame RemovalLog placement Lava rock and ember placementCleaning and maintenance Burner, Pilot and Control Compart- mentLogs Vent SystemGlass Door Rock woolPoSSIBLE Cause TroubleshootingStanding Pilot Ignition CDVSC7 & CDV7 Series Gas Fireplace Electronic Ignition YeSSignature Command System Operationfault Diagnosis ActionReplacement parts Firebox componentsCDVR33 CDVT33 CDVR36 CDVT36 CDVR42 CDVT42 CDVR47 CDVT47 Standing Pilot Millivolt control Fuel Conversion Kits Millivolt Natural Gas to LP Replacement PartsAccessories Description Qty Part Number LP to Natural GasCDVSC7 & CDV7 Series Gas Fireplace Electronic Ignition13,14,15,16,17 CDVR33NSC7 CDVR33SC7 Vertical Venting Description Model NumberHorizontal Venting 7TBRHTKCDVSC7 & CDV7 Series Gas Fireplace CDVSC7 & CDV7 Series Gas Fireplace Carbon Monoxide Detector Requirements Basic Warranty Lifetime WarrantyFive Year Warranty If Warranty Service is NeededMhsc Model EnerGuide Ratings Fireplace Efficiency %