ELECTRICAL INSTALLATION | CDVSC7 & CDV7 Series Gas Fireplace |
JUNCTION BOX WIRING
1.This should be done before framing the fireplace. Wire the receptacle into an electrical circuit. Wire with minimum 60° C wire in accordance with prevailing
codes.
2.Remove the external junction box cover by removing the screw from the side of the outside firebox wall. Junction box
was installed at the factory. |
|
|
|
|
|
|
|
|
| 120V AC |
|
|
|
|
|
|
|
|
| ||
3. The junction box cover has a factory installed “romex” style |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| 60Hz | |
|
|
|
|
|
|
| ||||
strain relief connector. After connecting the wires, route the |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
wire leads through this connector. Refer to the wiring dia- |
|
|
|
|
|
|
|
|
| Factory Supplied |
gram in Figure 54. |
|
|
|
|
|
|
|
|
| Not Supplied |
|
|
|
|
|
|
|
|
|
|
|
|
| Junction Box | ||||||||
| Figure 54 - | |||||||||
| Junction Box Wiring Diagram |
COMMAND CENTER WALL INSTALLATION
The command center may be mounted on the wall with the use of the SCSWEK Kit (15ft. cable, junction box, wall cover).
Mount the junction box provided at the desired location on the wall. Do not extend beyond the 15 ft. wire cable provided. If a longer distance is required, the 15 ft. may be extended up to 30 ft. maximum by using two (2) SCSWEK cables plugged together.
Route the wire from junction box to lower control area at bottom of fireplace. Unplug the 12" cable from the com- mand center. Attach the connector to the pins from wire by pushing in to connector making sure to follow the color code on connector. Plug the 15 ft. extension cable into the 2 ft. cable. Remove command center from the fireplace and plug the other end of the extension cable into the command center. Snap on wall cover provided and screw to junction box.
WALL SWITCH INSTALLATION
The wall switch wire connection is located off the 2 ft. wire harness from the control box to the command center. Fig- ure 55. The connection is labeled “Wall Switch”. Unplug the male and female connectors and connect the two (2) low voltage wires provided. Run wire to desired location on wall. Up to 50 ft. of 18 ga. wire may be used if neces- sary. Attach wires to wall switch. Mount the wall switch in to junction box and screw on cover.
WARNING | Do not connect wall switch to 110 V |
| |
| circuit. |
|
|