Monessen Hearth CDV7 manual Replacement Parts, Accessories Description Qty Part Number

Page 57

REPLACEMENT PARTS

 

 

CDVSC7 & CDV7 Series Gas Fireplace

Standing Pilot – Millivolt Control

 

 

 

 

 

 

 

 

 

Item

Description

Qty.

CDV33NV7 CDV33PV7 CDV36NV7 CDV36PV7 CDV42NV7 CDV42PV7 CDV47NV7 CDV47PV7

1.

Gas Valve Assy.

1

37D0117

37D0118

37D0117

37D0118 37D0117 37D0118 37D0117 37D0118

 

 

 

 

 

 

 

 

 

 

 

2.

Pilot Assembly

1

37D0018

37D0019

37D0018

37D0019

37D0018

37D0019

37D0018

37D0019

2C.

Replacement

 

 

 

 

 

 

 

 

 

 

Thermocouple

1

37D1067

37D1067

37D1067

37D1067

37D1067

37D1067

37D1067

37D1067

2I.

Replacement

 

 

 

 

 

 

 

 

 

 

Igniter and Wire

1

37D1069

37D1069

37D1069

37D1069

37D1069

37D1069

37D1069

37D1069

2T.

Replacement

 

 

 

 

 

 

 

 

 

 

Thermopile

1

37D1068

37D1068

37D1068

37D1068

37D1068

37D1068

37D1068

37D1068

3.

Burner Tube

1

54D0288

54D0288

69D0034

69D0034

69D0034

69D0034

69D0034

69D0034

4.

Flexhose with

 

 

 

 

 

 

 

 

 

 

Shut-off Valve

1

69D0030

69D0030

69D0030

69D0030

69D0030

69D0030

69D0030

69D0030

5.

Rocker Switch

1

41D0048

41D0048

41D0048

41D0048

41D0048

41D0048

41D0048

41D0048

6.

Piezo Igniter

1

14D0503

14D0503

14D0503

14D0503

14D0503

14D0503

14D0503

14D0503

7.

Injector

1

58D0371

69D0226

59D0062

69D0079

20H3155

33D4046

20H3155

33D4046

8.

Burner Assembly

1

54D0200

54D0200

54D0001

54D0001

54D0329

54D0329

54D0329

54D0329

9.

Venturi

1

69D1119

69D1026

69D1119

69D1026

69D1119

69D1026

69D1119

69D1026

10.

Wire Assembly

1

44D0500

44D0500

44D0500

44D0500

44D0500

44D0500

44D0500

44D0500

10.

Wire Assembly

1

44D0501

44D0501

44D0501

44D0501

44D0501

44D0501

44D0501

44D0501

Accessories

Item

Description

qty.

part Number

11.

Thermostatic Remote Control

1

RCST, RCT, RCSTE, RCSTEB, RCSITE, WWTD

12.

Remote Control ON/OFF

1

RCB, RCMT, RCBE, WMTD

13.

Wall Switch Kit

1

MVWS

14.

Wall Thermostat Kit

1

WT

Fuel Conversion Kits - Millivolt

Natural Gas to LP

 

CDV(R,T)33(V,E)

Kit #CDV33CKP

CDV(R,T)36(V,E)

Kit #CDV36CKP

CDV(R,T)42(V,E)

Kit #CDV42CKP

CDV(R,T)47(V,E)

Kit #CDV47CKP

LP to Natural Gas

 

CDV(R,T)33(V,E)

Kit #CDV33CKN

CDV(R,T)36(V,E)

Kit #CDV36CKN

CDV(R,T)42(V,E)

Kit #CDV42CKN

CDV(R,T)47(V,E)

Kit #CDV47CKN

69D3011

57

Image 57
Contents Cdvr CdvtDo not try to light any appliance Consumer Retain this manual for future refer- enceElectrical Wiring Pre-Installation InformationCheck Gas Pressure Signature Command System36 Operating Instructions Electronic IgnitionImportant Safety Information InstallerOwner Never connect unit to private non-utility Code ApprovalGas wells. This gas is commonly known As wellhead gasProduct Specifications Product featuresGAS Specifications & Orifice Size Cdvt Series GAS Specifications & Orifice Size Cdvr SeriesHigh Elevations GAS pressuresFireplace dimensions & Framing Framing DimensionsCDVR33V,E7 CDVT36 V,E,SC7 CDVT42 V,E,SC7 CDVT47 V,E,SC7 CDVT33V,E,SC7Cold Climate Insulation Fireplace Location Clearances Clearances to combustiblesMantel clearances Finishing Material Venting Installation Information Installation precautionsGeneral Venting General Venting Information Termination Location Canadian Installations1 US Installations2USA Installations Canadian InstallationsTermination Clearances Twist Lock Pipes Rear Vent Installation onlyRefer to Page 24 for snorkel requirements How to Use the Vent GraphVent Pipe Clearances Venting installationRear Wall Vent Installation Twist Lock Pipe Rear Wall Vent ApplicationStep Top vent Sidewall Application Rear Wall Vent Installations Flex Vent PipeSince it is very im Portant That Venting SystemMaximum number of 90 elbows per side wall Always install horizontal venting on a level plane Vertical Sidewall Installation Twist Lock PipeVertical Sidewall installation flex vent pipe Below Grade Installation Vertical THROUGH-THE-ROOF APPLICA- TionDo not back fill around snorkel Vertical THROUGH-THE-ROOF Installation Minimum Chimney Clearance Fireplace installation Install gas piping to fireplace / burner system locationCheck gas type Natural Gas Electrical Wiring Do not use open flame to check for gasLeaks Remote Wall mounted Switch Electrical installationDo not connect wall switch to 110 Remote Wall SwitchRemote Wall Switch. The appliance will Electronic Pilot Ignition WiringOptional Fan/Blower Systems Do not connect 110-120 VAC toMillivolt Operating Instructions Leak testingInitial lighting Never use an open flame to check for gas leakNever check for gas leak with open flame Approved leak testing methodMain burner switch Lighting the burnerPilot position If you do not follow these instruction Causing property damage, personalExactly, a fire or explosion may result Injury or loss of lifeElectrician. Main power must be off when Optional Accessory RequirementsConnecting to main electrical power supply Or performing service. All wiring shall beJunction BOX Wiring Electrical InstallationCommand Center Wall Installation Wall Switch InstallationElectrical Installation Optional FAN Blower Systems Blotsc Signature Command BlowerFK-12 Manual Blower Blot Automatic Thermostat BlowerOn next OPERATing Instructions Command CenterFeatures Battery InstallationCommand Center System CONFIGURATION/SETUP Key Combinations for System SettingsFunction Operation Default Setting Self Diagnostics Chart Command Center OperationsFUNCTIONS/OPERATION Function OperationGlass Frame Removal Rock wool placementLava rock and ember placement Log placementBurner, Pilot and Control Compart- ment Cleaning and maintenanceGlass Door Vent SystemLogs Rock woolTroubleshooting Standing Pilot IgnitionPoSSIBLE Cause CDVSC7 & CDV7 Series Gas Fireplace YeS Electronic IgnitionOperationfault Diagnosis Action Signature Command SystemFirebox components Replacement partsCDVR33 CDVT33 CDVR36 CDVT36 CDVR42 CDVT42 CDVR47 CDVT47 Standing Pilot Millivolt control Accessories Description Qty Part Number Replacement PartsFuel Conversion Kits Millivolt Natural Gas to LP LP to Natural GasElectronic Ignition CDVSC7 & CDV7 Series Gas Fireplace13,14,15,16,17 CDVR33NSC7 CDVR33SC7 Description Model Number Vertical Venting7TBRHTK Horizontal VentingCDVSC7 & CDV7 Series Gas Fireplace CDVSC7 & CDV7 Series Gas Fireplace Carbon Monoxide Detector Requirements Five Year Warranty Lifetime WarrantyBasic Warranty If Warranty Service is NeededModel EnerGuide Ratings Fireplace Efficiency % Mhsc