Monessen Hearth Understanding the TSFSC Remote for Enhanced Control of Your Fireplace

Page 43

SIGNATURE COMMAND SYSTEM OPERATION INSTRUCTIONCDVSC7 & CDV7 Series Gas Fireplace

FEATURES

Command Center

Easy Access Function Operation and System Configuration

Operation Confirmation/Fault Diagnostic Indications (LED/ Buzzer)

ON/OFF/HI/Med/Low Operation

Optional Wall Mounting

Control Board

Electronic Ignition

Pilot Lockout safety feature

Electric Power Regeneration from Thermopile to save bat- tery

6-hour Automatic Shut Down Option

Convenient NG/LP Gas Type Conversion

Standing Pilot/Intermittent pilot Conversion

Previous settings Restoration Ability (Memory Off)

Uninterrupted Operation During Power Outage (Automatic Battery Backup)

ON/OFF RF Remote Receiver

Optional Transmitter Learn Capability

AC Module Board (Optional, requires TSFSC Remote)

Easy Snap-on Design

Embedded Compact 120 VAC Adapter with Auto Battery Back up Feature

RF Receiver

To Thermopile

 

ON/OFF

To Sensor

To Sparker

NG/LP

Conversion

Control

 

Board

To Command Center

To Stepper Motor

To Valve

OFF

LED

ON

Master Switch

Command

Center

Battery Door

Figure 60 -

Signature Command System Components

Remote Controlled 3-step Blower, Lighting, and On/Off Auxiliary AC Outputs

Transmitter (Optional)

TSFSC

TSTSC

TSMSC

RTSC

RMSC

Three Flame Height Settings

X

X

X

X

X

Low battery Indication for Transmitter

X

X

X

X

X

Child Proof Lock-out

X

X

X

X

X

LCD Backlight

X

X

X

X

X

Security Codes 16

X

X

X

X

X

Countdown 6 hr Timer

X

X

X

--

--

Standard Thermostatic Control Mode

X

X

--

X

--

Smart Mode Thermostat (Auto Flame & Blower Modulation)

X

X

--

--

--

Three Brightness Settings for Lights

X

--

--

--

--

Three Speed Control for Blower

X

--

--

--

--

On/Off Auxiliary

X

--

--

--

--

Programmable Timer to turn blower on and off

X

--

--

--

--

BATTERY INSTALLATION

The Command Center uses four (4) "AA" batteries as back up for power outages. The system can operate for ap- proximately six (6) months on battery power.

To Install Batteries (not included):

1.Press down the battery door tabs and pull out to remove battery door.

2.Install the batteries as indicated on Command Center.

3.Close battery door by snapping in place.

4.When the four (4) batteries are installed the system will operate without power.

5.The batteries should be replaced when the LED indicates low battery or at least once a year.

69D3011

43

Image 43
Contents Consumer Retain this manual for future refer- ence CdvtCdvr Do not try to light any applianceOperating Instructions Electronic Ignition Pre-Installation InformationElectrical Wiring Check Gas Pressure Signature Command System36Installer Important Safety InformationOwner As wellhead gas Code ApprovalNever connect unit to private non-utility Gas wells. This gas is commonly knownProduct Specifications Product featuresGAS pressures GAS Specifications & Orifice Size Cdvr SeriesGAS Specifications & Orifice Size Cdvt Series High ElevationsFraming Dimensions Fireplace dimensions & FramingCDVR33V,E7 CDVT36 V,E,SC7 CDVT42 V,E,SC7 CDVT47 V,E,SC7 CDVT33V,E,SC7Cold Climate Insulation Fireplace Location Clearances to combustibles ClearancesMantel clearances Finishing Material Installation precautions Venting Installation InformationGeneral Venting General Venting Information Termination Location Canadian Installations1 US Installations2Canadian Installations USA InstallationsTermination Clearances Twist Lock Pipes Rear Vent Installation onlyRefer to Page 24 for snorkel requirements How to Use the Vent GraphVent Pipe Clearances Venting installationRear Wall Vent Application Rear Wall Vent Installation Twist Lock PipeStep Venting System Rear Wall Vent Installations Flex Vent PipeTop vent Sidewall Application Since it is very im Portant ThatMaximum number of 90 elbows per side wall Always install horizontal venting on a level plane Vertical Sidewall Installation Twist Lock PipeVertical Sidewall installation flex vent pipe Vertical THROUGH-THE-ROOF APPLICA- Tion Below Grade InstallationDo not back fill around snorkel Vertical THROUGH-THE-ROOF Installation Minimum Chimney Clearance Install gas piping to fireplace / burner system location Fireplace installationCheck gas type Natural Gas Do not use open flame to check for gas Electrical WiringLeaks Remote Wall Switch Electrical installationRemote Wall mounted Switch Do not connect wall switch to 110Do not connect 110-120 VAC to Electronic Pilot Ignition WiringRemote Wall Switch. The appliance will Optional Fan/Blower SystemsNever use an open flame to check for gas leak Leak testingMillivolt Operating Instructions Initial lightingNever check for gas leak with open flame Approved leak testing methodLighting the burner Main burner switchPilot position Injury or loss of life Causing property damage, personalIf you do not follow these instruction Exactly, a fire or explosion may resultOr performing service. All wiring shall be Optional Accessory RequirementsElectrician. Main power must be off when Connecting to main electrical power supplyWall Switch Installation Electrical InstallationJunction BOX Wiring Command Center Wall InstallationElectrical Installation Optional FAN Blower Systems Blotsc Signature Command BlowerFK-12 Manual Blower Blot Automatic Thermostat BlowerOn next OPERATing Instructions Command CenterBattery Installation FeaturesCommand Center Key Combinations for System Settings System CONFIGURATION/SETUPFunction Operation Default Setting Function Operation Command Center OperationsSelf Diagnostics Chart FUNCTIONS/OPERATIONGlass Frame Removal Rock wool placementLava rock and ember placement Log placementBurner, Pilot and Control Compart- ment Cleaning and maintenanceRock wool Vent SystemGlass Door LogsStanding Pilot Ignition TroubleshootingPoSSIBLE Cause CDVSC7 & CDV7 Series Gas Fireplace YeS Electronic IgnitionOperationfault Diagnosis Action Signature Command SystemFirebox components Replacement partsCDVR33 CDVT33 CDVR36 CDVT36 CDVR42 CDVT42 CDVR47 CDVT47 Standing Pilot Millivolt control LP to Natural Gas Replacement PartsAccessories Description Qty Part Number Fuel Conversion Kits Millivolt Natural Gas to LPElectronic Ignition CDVSC7 & CDV7 Series Gas Fireplace13,14,15,16,17 CDVR33NSC7 CDVR33SC7 Description Model Number Vertical Venting7TBRHTK Horizontal VentingCDVSC7 & CDV7 Series Gas Fireplace CDVSC7 & CDV7 Series Gas Fireplace Carbon Monoxide Detector Requirements If Warranty Service is Needed Lifetime WarrantyFive Year Warranty Basic WarrantyModel EnerGuide Ratings Fireplace Efficiency % Mhsc