Monessen Hearth CDV7 manual CDVR33 CDVT33 CDVR36 CDVT36 CDVR42 CDVT42 CDVR47 CDVT47

Page 55

replacement parts

 

 

 

CDVSC7 & CDV7 Series Gas Fireplace

firebox components

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Item

Description

Qty.

CDVR33

CDVT33

CDVR36

CDVT36

CDVR42

CDVT42

CDVR47

CDVT47

Standard Features

 

 

 

 

 

 

 

 

 

1.

Junction Box Assy

1

26D2128K

26D2128K

26D2128K 26D2128K 26D2128K 26D2128K 26D2128K 26D2128K

2.

Black Louver

6

54D0246

54D0246

26D0695

26D0695

26D0697

26D0697

26D0699

26D0699

3.

Glass Frame Assy

1

69D0238

69D0238

69D0028

69D0028

69D1107

69D1107

69D2105

69D2105

Factory Installed Service Parts

 

 

 

 

 

 

 

 

2.

Brass Louver

6

54D0249K

54D0249K

26D0701K 26D0701K 26D0703K 26D0703K 26D0705K 26D0705K

4.

Thermostat Sensor

1

26D2870

26D2870

26D2870

26D2870

26D2870

26D2870

26D2870

26D2870

 

for Blower

 

 

 

 

 

 

 

 

 

5.

Firebrick Rear

1

69D0221

26D7069

69D0040

69D0041

69D1023

69D1022

69D2019

69D2020

 

- Cottage Clay

 

 

 

 

 

 

 

 

 

5.

Firebrick Rear

1

69D0222

54D0284

69D0044

69D0045

69D1025

69D1024

69D2021

69D2022

 

- Tavern Brown

 

 

 

 

 

 

 

 

 

6a.

Firebrick Right / Left

2

26D7068

26D7068

69D0042

69D0042

69D0042

69D0042

69D0042

69D0042

 

- Cottage Clay

 

 

 

 

 

 

 

 

 

6b.

Firebrick Right / Left

2

20300900

--

--

--

--

--

--

--

 

- Cottage Clay - CDVR33SC7 ONLY

 

 

 

 

 

 

 

6a.

Firebrick Right / Left

2

54D0285

54D0285

69D0046

69D0046

69D0046

69D0046

69D0046

69D0046

 

- Tavern Brown

 

 

 

 

 

 

 

 

 

6b.

Firebrick Right / Left

2

20301197

--

--

--

--

--

--

--

 

- Tavern Brown - CDVR33SC7 ONLY

 

 

 

 

 

 

 

7.

Blower Motor

1

93D0006

93D0006

93D0006

93D0006

93D0006

93D0006

93D0006

93D0006

Accessories/Field Installed Options

 

 

 

 

 

 

 

2.

Brass Louver

1

L30BR

L30BR

L32BR

L32BR

L36BR

L36BR

L42BR

L42BR

2.

Pewter Louver

1

L30PW

L30PW

L32PW

L32PW

L36PW

L36PW

L42PW

L42PW

9.

Curved Design

 

 

 

 

 

 

 

 

 

 

- Brass Trim

1

BRTK30C

BRTC30C

BRTK32C

BRTK32C

BRTK36C

BRTK36C

BRTK42C

BRTK42C

9.

Curved Design

 

 

 

 

 

 

 

 

 

 

- Pewter Trim

1

PWTK30C

PWTK30C

PWTK32C PWTK32C PWTK36C PWTK36C PWTK36C PWTK36C

10.

T-stat Blower w/

1

BLOT

BLOT

BLOT

BLOT

BLOT

BLOT

BLOT

BLOT

 

Speed Control

 

 

 

 

 

 

 

 

 

11.

Manual Blower

1

FK12

FK12

FK12

FK12

FK12

FK12

FK12

FK12

12.

Speed Control

1

26D0746

26D0746

26D0746

26D0746

26D0746

26D0746

26D0746

26D0746

13.

SCS Blower

1

BLOTSC

BLOTSC

BLOTSC

BLOTSC

BLOTSC

BLOTSC

BLOTSC

BLOTSC

w/ Speed Control & Time Delay

69D3011

55

Image 55
Contents Consumer Retain this manual for future refer- ence CdvtCdvr Do not try to light any applianceOperating Instructions Electronic Ignition Pre-Installation InformationElectrical Wiring Check Gas Pressure Signature Command System36Installer Important Safety InformationOwner As wellhead gas Code ApprovalNever connect unit to private non-utility Gas wells. This gas is commonly knownProduct Specifications Product featuresGAS pressures GAS Specifications & Orifice Size Cdvr SeriesGAS Specifications & Orifice Size Cdvt Series High ElevationsFraming Dimensions Fireplace dimensions & FramingCDVR33V,E7 CDVT36 V,E,SC7 CDVT42 V,E,SC7 CDVT47 V,E,SC7 CDVT33V,E,SC7Cold Climate Insulation Fireplace Location Clearances to combustibles ClearancesMantel clearances Finishing Material Installation precautions Venting Installation InformationGeneral Venting General Venting Information Termination Location Canadian Installations1 US Installations2Canadian Installations USA InstallationsTermination Clearances Twist Lock Pipes Rear Vent Installation onlyRefer to Page 24 for snorkel requirements How to Use the Vent GraphVent Pipe Clearances Venting installationRear Wall Vent Application Rear Wall Vent Installation Twist Lock PipeStep Venting System Rear Wall Vent Installations Flex Vent PipeTop vent Sidewall Application Since it is very im Portant ThatMaximum number of 90 elbows per side wall Always install horizontal venting on a level plane Vertical Sidewall Installation Twist Lock PipeVertical Sidewall installation flex vent pipe Vertical THROUGH-THE-ROOF APPLICA- Tion Below Grade InstallationDo not back fill around snorkel Vertical THROUGH-THE-ROOF Installation Minimum Chimney Clearance Install gas piping to fireplace / burner system location Fireplace installationCheck gas type Natural Gas Do not use open flame to check for gas Electrical WiringLeaks Remote Wall Switch Electrical installationRemote Wall mounted Switch Do not connect wall switch to 110Do not connect 110-120 VAC to Electronic Pilot Ignition WiringRemote Wall Switch. The appliance will Optional Fan/Blower SystemsNever use an open flame to check for gas leak Leak testingMillivolt Operating Instructions Initial lightingNever check for gas leak with open flame Approved leak testing methodLighting the burner Main burner switchPilot position Injury or loss of life Causing property damage, personalIf you do not follow these instruction Exactly, a fire or explosion may resultOr performing service. All wiring shall be Optional Accessory RequirementsElectrician. Main power must be off when Connecting to main electrical power supplyWall Switch Installation Electrical InstallationJunction BOX Wiring Command Center Wall InstallationElectrical Installation Optional FAN Blower Systems Blotsc Signature Command BlowerFK-12 Manual Blower Blot Automatic Thermostat BlowerOn next OPERATing Instructions Command CenterBattery Installation FeaturesCommand Center Key Combinations for System Settings System CONFIGURATION/SETUPFunction Operation Default Setting Function Operation Command Center OperationsSelf Diagnostics Chart FUNCTIONS/OPERATIONGlass Frame Removal Rock wool placementLava rock and ember placement Log placementBurner, Pilot and Control Compart- ment Cleaning and maintenanceRock wool Vent SystemGlass Door LogsStanding Pilot Ignition TroubleshootingPoSSIBLE Cause CDVSC7 & CDV7 Series Gas Fireplace YeS Electronic IgnitionOperationfault Diagnosis Action Signature Command SystemFirebox components Replacement partsCDVR33 CDVT33 CDVR36 CDVT36 CDVR42 CDVT42 CDVR47 CDVT47 Standing Pilot Millivolt control LP to Natural Gas Replacement PartsAccessories Description Qty Part Number Fuel Conversion Kits Millivolt Natural Gas to LPElectronic Ignition CDVSC7 & CDV7 Series Gas Fireplace13,14,15,16,17 CDVR33NSC7 CDVR33SC7 Description Model Number Vertical Venting7TBRHTK Horizontal VentingCDVSC7 & CDV7 Series Gas Fireplace CDVSC7 & CDV7 Series Gas Fireplace Carbon Monoxide Detector Requirements If Warranty Service is Needed Lifetime WarrantyFive Year Warranty Basic WarrantyModel EnerGuide Ratings Fireplace Efficiency % Mhsc