Monessen Hearth CDV7 manual Glass Frame Removal, Rock wool placement

Page 46

CDVSC7 & CDV7 Series Gas Fireplace glass removal & ROCK WOOL PLACEMENT

Glass Frame Removal

1. Remove upper and lower louvers.

2. Release the clamps on the bottom of the fireplace. Figure 61

3. Tilt glass frame out and lift glass frame up until it clears the hook on top of the frame.

4. Set glass frame aside.

Glass Frame

CAUTION

Each clamp has a quick spring force. When

 

 

reinstalling clamps, keep fingers clear.

! WARNING

HOT GLASS WILL

CAUSE BURNS.

DO NOT TOUCH GLASS

UNTIL COOLED.

NEVER ALLOW CHILDREN

TO TOUCH GLASS.

rock wool placement

Clamps -

2 on 33/36 Models,

3 on 42/47 Models

Figure 61 -

FP2297

Removing Glass Frame - CDVR Series Shown

 

Burner

1.For best results in flame appearance and opera- tion, use one (1) 8 gram bag of rock wool for propane/LP models and up to three (3) bags of rock wool for natural gas models.

2.Pull the rock wool apart into dime-sized pieces or smaller. Cover the entire surface of the burner with one thin layer of rock wool.

3.Place the logs on the burner. Refer to the “Log Placement Section”. Light the unit and after 15 minutes check burner flame and glow. Adjust embers as necessary to achieve an even and clean flame.

Cover with

FP2648

Rock Wool

 

Figure 62 - Placement of Rock

Wool on Burner

WARNING

The use of too much rock wool could cause flame to burn poorly and may cause sooting.

46

69D3011

Image 46
Contents Do not try to light any appliance CdvtCdvr Consumer Retain this manual for future refer- enceCheck Gas Pressure Signature Command System36 Pre-Installation InformationElectrical Wiring Operating Instructions Electronic IgnitionInstaller Important Safety InformationOwner Gas wells. This gas is commonly known Code ApprovalNever connect unit to private non-utility As wellhead gasProduct features Product SpecificationsHigh Elevations GAS Specifications & Orifice Size Cdvr SeriesGAS Specifications & Orifice Size Cdvt Series GAS pressuresFraming Dimensions Fireplace dimensions & FramingCDVR33V,E7 CDVT33V,E,SC7 CDVT36 V,E,SC7 CDVT42 V,E,SC7 CDVT47 V,E,SC7Cold Climate Insulation Fireplace Location Clearances to combustibles ClearancesMantel clearances Finishing Material Installation precautions Venting Installation InformationGeneral Venting Canadian Installations1 US Installations2 General Venting Information Termination LocationCanadian Installations USA InstallationsTermination Clearances Rear Vent Installation only Twist Lock PipesHow to Use the Vent Graph Refer to Page 24 for snorkel requirementsVenting installation Vent Pipe ClearancesRear Wall Vent Application Rear Wall Vent Installation Twist Lock PipeStep Since it is very im Portant That Rear Wall Vent Installations Flex Vent PipeTop vent Sidewall Application Venting SystemMaximum number of 90 elbows per side wall Vertical Sidewall Installation Twist Lock Pipe Always install horizontal venting on a level planeVertical Sidewall installation flex vent pipe Vertical THROUGH-THE-ROOF APPLICA- Tion Below Grade InstallationDo not back fill around snorkel Vertical THROUGH-THE-ROOF Installation Minimum Chimney Clearance Install gas piping to fireplace / burner system location Fireplace installationCheck gas type Natural Gas Do not use open flame to check for gas Electrical WiringLeaks Do not connect wall switch to 110 Electrical installationRemote Wall mounted Switch Remote Wall SwitchOptional Fan/Blower Systems Electronic Pilot Ignition WiringRemote Wall Switch. The appliance will Do not connect 110-120 VAC toInitial lighting Leak testingMillivolt Operating Instructions Never use an open flame to check for gas leakApproved leak testing method Never check for gas leak with open flameLighting the burner Main burner switchPilot position Exactly, a fire or explosion may result Causing property damage, personalIf you do not follow these instruction Injury or loss of lifeConnecting to main electrical power supply Optional Accessory RequirementsElectrician. Main power must be off when Or performing service. All wiring shall beCommand Center Wall Installation Electrical InstallationJunction BOX Wiring Wall Switch InstallationElectrical Installation Blotsc Signature Command Blower Optional FAN Blower SystemsBlot Automatic Thermostat Blower FK-12 Manual BlowerOn next Command Center OPERATing InstructionsBattery Installation FeaturesCommand Center Key Combinations for System Settings System CONFIGURATION/SETUPFunction Operation Default Setting FUNCTIONS/OPERATION Command Center OperationsSelf Diagnostics Chart Function OperationRock wool placement Glass Frame RemovalLog placement Lava rock and ember placementCleaning and maintenance Burner, Pilot and Control Compart- mentLogs Vent SystemGlass Door Rock woolStanding Pilot Ignition TroubleshootingPoSSIBLE Cause CDVSC7 & CDV7 Series Gas Fireplace Electronic Ignition YeSSignature Command System Operationfault Diagnosis ActionReplacement parts Firebox componentsCDVR33 CDVT33 CDVR36 CDVT36 CDVR42 CDVT42 CDVR47 CDVT47 Standing Pilot Millivolt control Fuel Conversion Kits Millivolt Natural Gas to LP Replacement PartsAccessories Description Qty Part Number LP to Natural GasCDVSC7 & CDV7 Series Gas Fireplace Electronic Ignition13,14,15,16,17 CDVR33NSC7 CDVR33SC7 Vertical Venting Description Model NumberHorizontal Venting 7TBRHTKCDVSC7 & CDV7 Series Gas Fireplace CDVSC7 & CDV7 Series Gas Fireplace Carbon Monoxide Detector Requirements Basic Warranty Lifetime WarrantyFive Year Warranty If Warranty Service is NeededMhsc Model EnerGuide Ratings Fireplace Efficiency %