Top Vent - Vertical Termination
Venting with 3 elbows
|
|
|
|
| SLR |
|
| |
Î |
| V1 Minimum | H1 + H2 Maximum |
| V2 | V1 + V2 Minimum | ||
|
| 90° Elbow | 1 ft. | 305 mm |
| * | * | |
| 1 ft. |
| 305 mm | 2 ft. | 610 mm |
| * | * |
| 2 ft. |
| 610 mm | 4 ft. | 1.2 m |
| * | * |
| 3 ft. |
| 914 mm | 6 ft. | 1.8 m |
| * | * |
| 4 ft. |
| 1.2 m | 14 ft. | 4.3 m |
| * | * |
|
|
|
| H MAX. =14 ft. (4.3 m) |
|
| ||
|
|
|
| V1 + V2 + H1 + H2 MAX. = 40 ft. (12.2 m) |
|
| ||
| * No specific restrictions on this value EXCEPT V1 + V2 + H1 + H2 cannot exceed 40 ft. (12.2 m) |
V2
Note: Use SLP Series components only.
Note: There MUST be a 25% reduction in total H when using flex vent except when using the simple up and out installation (see Figure 7.3).
H1
H2 | V1 |
| |
| INSTALLED |
| HORIZONTALLY |
Figure 7.12
Heat & Glo • SLR • | 29 |