12 Electrical Information
A. Wiring Requirements
NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA
Code CSA C22.1.
•Wire the appliance junction box to
•Low voltage and 110 VAC voltage cannot be shared within the same wall box.
WARNING! Risk of Shock or Explosion! DO NOT wire 110V to the valve or to the appliance wall switch. Incorrect wiring will damage controls.
B. Intellifire Ignition System Wiring
•Wire the appliance junction box to 110 VAC for proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT wire IPI controlled appliance junction box to a switched circuit. Incorrect wiring will override IPI safety lockout.
•Refer to Figure 12.2, Intellifire Pilot Ignition (IPI) Wiring Diagram.
•This appliance is equipped with an Intellifire control valve which operates on a 3 volt system.
•Plug the
NOTICE: Batteries should not be placed in the battery pack while using the transformer. Remove batteries before using the transformer, and unplug the transformer before installing the batteries. Battery polarity must be correct or module damage will occur.
C. Optional Accessories Requirements
•This appliance may be used with a wall switch, wall mounted thermostat and/or a remote control.
Wiring for optional Hearth & Home Technologies approved accessories should be done now to avoid reconstruction. Follow instructions that come with those accessories.
Optional Remote Control Receiver and Battery Pack Location
Batteries are to be installed only when battery power is | Î |
| |
required. Because of the limited accessibility to valve |
|
cavity, the position of the Battery Tray, IPI Control Module, |
|
and Optional Remote Control Receiver locations must be |
|
installed as shown in Figure 12.1. |
|
The Battery Tray, Control Module, and Remote Control |
|
receiver can be accessed thru the air space between the |
|
firebox front and the |
|
decorative front and glass assembly must be removed to |
|
access these components. |
|
The battery tray is attached with velcro to the inside of |
|
the lower cover panel. The IPI control module and the |
|
remote control receiver are placed on the firebox bottom. |
|
FIREBOX BOTTOM
BATTERY TRAY
IPI CONTROL MODULE | REMOTE CONTROL RECEIVER |
LOWER ACCESS PANEL
Figure 12.1 Valve Cavity
Heat & Glo • SLR • | 45 |