Heat & Glo LifeStyle SLR (COSMO) owner manual Service Parts List, Stocked, At Depot

Page 65

C. Service Parts List

 

 

SLR

IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement

 

 

 

Stocked

parts for your appliance please provide model number and serial number. All parts listed

 

in this manual may be ordered from an authorized dealer.

 

 

at Depot

ITEM

DESCRIPTION

COMMENTS

PART NUMBER

 

1

Elbow Heat Shield

 

2143-168

n

2

Sheet Rock Ledge

 

2143-147

N

3

Top Panel, Finishing Edge

 

2143-102

N

4

Non Combustible Board

 

2143-117

N

5

Base Pan

 

2143-115

N

6

Burner NG

 

2143-007

Y

Burner LP

 

2143-008

Y

 

 

7

Pilot Bracket

 

2143-123

n

8

Glass Door Assembly

 

GLA-SLR

Y

9

Junction Box

 

4013-021

Y

10

Lower Cover Panel

 

2143-103

N

 

 

 

 

 

 

12 in Pipe

 

SLP12

N

 

Black Rock

10 LB Bag

2143-850

N

 

Gasket Assembly

 

 

 

 

Contains burner neck, shutter bracket, vent, seal cap,

 

2121-080

N

 

valve plate, and air passage gaskets

 

 

 

 

Glass Latch Assembly

Qty 2 req

386-122A

Y

 

Finish Edge

Right

2143-118

N

 

Left

2143-169

 

 

 

 

 

Touch Up Paint

 

TUP-GBK-12

N

 

Wall Switch Kit

 

WSK-21

N

 

Conversion Kit NG

N/A

N

 

Conversion Kit LP

LPK-SLR

Y

 

Pilot Orifice NG

593-528

Y

 

Pilot Orifice LP

593-527

Y

 

Regulator NG

NGK-DXF

Y

 

Regulator LP

LPK-DXF

Y

Additional service part numbers appear on following page.

Heat & Glo • SLR • 2143-900 Rev. B • 7/08

65

Image 65
Contents What to do if you smell gas Model SLR CosmoHomeowner Reference Information CongratulationsUser Guide Table of ContentsTroubleshooting Appliance SetupFinishing Reference MaterialsLimited Lifetime Warranty Heat & GLO GAS Appliance Products Limited Lifetime WarrantyListing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsYour Fireplace Gas Fireplace SafetyOperating Instructions User Guide Remote Controls, Wall Controls and Wall Switches Fixed Glass AssemblyClear Space Decorative Doors and FrontsFinal inspection by Lighting Instructions IPIAfter Fireplace is Lit Frequently Asked QuestionsInitial Break-in Procedure Maintenance Tasks-Homeowner Maintenance and ServiceGlass Cleaning Remote ControlGasket Seal and Glass Assembly Inspection Maintenance Tasks-Qualified Service TechnicianVenting FireboxTypical Appliance System Getting StartedInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Selecting Appliance Location Framing and ClearancesClearances Constructing the Appliance ChaseCombustible Mantels Mantel and Wall ProjectionsNon-combustible Mantels Front Side Finishing DetailAIR Space Vent Termination Minimum Clearances Termination LocationsCovered Alcove Applications Vent Information and Diagrams Minimum Maximum Top Vent Horizontal Termination Venting with 1 elbowTop Vent Horizontal Termination Venting with 2 elbows Venting with 3 elbows Top Vent Horizontal TerminationTop Vent Horizontal Termination Venting with 3 elbows Exhaust restrictor Instructions Top Vent Vertical Termination No Elbows V1 = 44 ft. Max .4 mV1 Minimum Maximum V1 + V2 Minimum Top Vent Vertical Termination Venting with 2 elbowsTop Vent Vertical Termination Venting with 3 elbows V1 MIN H1 MAX V2 MIN H2 MAX V3 MIN Top Vent Vertical Termination Venting with 4 elbowsPipe Clearances to Combustibles Vent Clearances and FramingWall Penetration Framing Combustible Wall PenetrationPipe SLP Install the Ceiling FirestopVaulted Ceiling Installation Install Attic Insulation ShieldFlat Ceiling Installation Top Vent Appliance PreparationProper Positioning, Leveling And Securing Of An Securing and Leveling the ApplianceAssemble Vent Sections Installing Vent Pipe SLP PipeSecure The Vent Sections Assemble Slip SectionsDisassemble Vent Sections Install Decorative Ceiling ComponentsAssemble and Install Storm Collar Install Metal Roof Flashing15 Secure Pipe with SLP-FS Install RF4-8Heat Shield Requirements for Horizontal Termination Install Vertical Termination CapInstall Decorative Wall Components 22 Venting through the wall Install Horizontal Termination CapGas Pressure Gas InformationFuel Conversion Gas Connection Gas Fitting AccessIntellifire Ignition System Wiring Wiring RequirementsOptional Accessories Requirements Electrical InformationJunction Box Detail Electrical Service and Repair Junction Box InstallationFraming and Finishing Instructions FinishingFinishing Details Confirm Fireplace Opening Dimension Opening 12 Overlap Fit Method Tonic or Martini Decorative Front Facing Material14 Inside Fit Method Tonic Decorative Front Only 17 Tonic Decorative Front Decorative FrontsRemove Fixed Glass Assembly Appliance SetupClean the Appliance AccessoriesRock Media Instructions Cleaning the RockScrew Air Shutter Settings Install the MeshAir Shutter Setting Intellifire Ignition System TroubleshootingSymptom Possible Cause Corrective Action Remove any contaminants that may have accumulated on Reference Materials Appliance Dimension DiagramDVP-BEK2 Vent Components DiagramsSLP90- 90 Elbow SLP-45 45 ElbowExtended Heat Shield RF4-8Support Box-Black PVK-80Horizontal Ceiling Firestop AdapterPart number list on following Service PartsAt Depot Service Parts ListStocked IPI Valve Assembly Contact Information