Heat & Glo LifeStyle 2137-900 owner manual Stone Placement Soho24B, Positioning Stones

Page 35

D. Positioning Stones

For proper performance and safety, it is critical that the Black Onyx stones are set up in accordance with these instructions.

Stone Placement: Soho24B

WARNING! Choking Hazard! Keep stones out of reach of children.

BURNER AREA

Figure 12.1.

As you are positioning the stones, make sure that no stones are in the cross-hatched area shown between the two arrows above. This is to ensure proper lighting and avoid interference with the pilot flame.

WARNING

Delayed Ignition Risk

•Place stones according to instructions.

•Do NOT place stones in area in front of pilot shield.

•Do NOT place stones in a position that they may fall into area in front of pilot shield.

•Do NOT use any media other than the stones supplied with this fireplace.

Fireplace will not function properly.

Delayed ignition may occur.

JIG

PILOT SHIELD

Figure 2.

Step 1. The included stone placement jig MUST be used any time stones are placed on the burner to ensure that none end up in the cross-hatched area noted in Figure 1.

Figure 12.3.

Step 2. The stone placement jig is shipped in its proper position. Remove the two screws securing the jig, making sure the jig stays in the proper position. See Figure 3.

Figure 12.4.

Step 3. Place a single layer of stones over the burner area inside of the tabs surrounding the burner and behind the pilot shield.

Figure 12.5.

Step 4. Place the remaining stones over the basepan taking care not to add more stones to the burner area.

2137-936C

Heat & Glo • Soho24B • 2137-900 Rev. P • 8/12

35

Image 35
Contents Hot glass will cause burns Model Soho24BWhat to do if you smell gas Homeowner Reference Information CongratulationsTable of Contents Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsTools and Supplies Needed Installation to ensure maximum safety and benefitGetting Started Mantel Projections Framing and ClearancesSelecting Appliance Location Clearances Constructing the Appliance ChaseSee .4 for specific clearances Termination LocationsVent Termination Minimum Clearances Inches U.S.A Covered Alcove ApplicationsMeasuring Standards Vent Information and DiagramsVent Table Key Use of ElbowsMinimum Maximum Vent DiagramsTop Vent Horizontal Termination One Elbow Two ElbowsV1 Min H1 Max V2 Min H2 Max Top Vent Horizontal Termination Three ElbowsV1 Minimum H1 Maximum V1 + Top Vent Vertical Termination No ElbowV1 = 45 ft Max .72 m V1 = 3 ft Min mm V1 Minimum H1+ H2 Maximum V1+ V2 Minimum Top Vent Vertical Termination Three ElbowsCombustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration FramingPipe SLP Vertical Penetration FramingVaulted Ceiling Installation Install Attic Insulation ShieldFlat Ceiling Installation Top Vent Appliance PreparationMaterial Installation of Non-combustible Facing MaterialProper Positioning, Leveling and Securing of a Securing and Leveling the ApplianceAssemble Vent Sections Installing Vent PipeSecure the Vent Sections Assemble Slip SectionsDisassemble Vent Sections Install Decorative Ceiling ComponentsAssemble and Install Storm Collar Install Metal Roof FlashingHeat Shield Requirements for Horizontal Termination Install Vertical Termination CapInstall Decorative Wall Components 17 Venting through the wall Install Horizontal Termination CapPressure Natural Gas Propane Gas InformationFuel Conversions Gas Connection Gas PressuresHigh Altitude Installations Electrical Information Recommendation for WireGRN wire Ground attached To GRN screw with Inside box Junction Box InstallationSee for combustible/non-combustible definitions FinishingFacing Material Painting Installation of Non-Combustible Facing MaterialsRemove Shipping Materials Appliance SetupClean the Appliance AccessoriesPositioning Stones Stone Placement Soho24BNo Stones in this Area Replacing Glass Assembly Glass AssemblyAir Shutter Setting Removing Glass AssemblyBefore Lighting Appliance Operating InstructionsFinal inspection by Lighting Instructions IPIAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Sympton Possible Cause Corrective Action TroubleshootingIntelliFire Ignition System Symptom Possible Cause Corrective Action Maintaining and Servicing Appliance Maintenance TasksRecommend addition of screen if one is not present Inspect Maintenance TasksLocation Inches Millimeter Appliance Dimension DiagramAppliance Dimensions Table Reference MaterialsSL Series Components Vent Components Diagrams B. Vent Components Diagrams Assembly 318 mm 356 mm 330 mm305 mm 12-1/224 x 24 Direct Vent Fireplace Service PartsStocked At Depot#11 IPI Valve Assembly No longer available SOHO24B-ONYXLimited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Contact Information