Heat & Glo LifeStyle 2137-900 owner manual Getting Started, Tools and Supplies Needed

Page 6

2 Getting Started

A. Design and Installation Considerations

C. Inspect Appliance and Components

Heat & Glo direct vent gas appliances are designed to

 

 

WARNING

operate with all combustion air siphoned from outside of

 

 

the building and all exhaust gases expelled to the outside.

 

 

Inspect appliance and components for damage.

No additional outside air source is required.

 

 

 

 

Damaged parts may impair safe operation.

 

 

CAUTION

 

 

• Do NOT install damaged components.

 

 

 

 

• Do NOT install incomplete components.

 

 

 

 

 

 

 

 

 

 

 

 

• Do NOT install substitute components.

 

Check building codes prior to installation.

 

 

Report damaged parts to dealer.

 

• Installation MUST comply with local, regional, state and

 

 

 

 

national codes and regulations.

Carefully remove the appliance and components from

 

• Consult local building, fire officials or authorities having jurisdic-

 

 

the packaging.

 

tion about restrictions, installation inspection, and permits.

 

 

 

 

 

• The vent system components and trim doors are shipped

When planning an appliance installation, it’s necessary to

 

in separate packages.

The gas logs may be packaged separately and must be

determine the following information before installing:

Where the appliance is to be installed.

 

field installed.

Report to your dealer any parts damaged in shipment,

The vent system configuration to be used.

 

particularly the condition of the glass.

Gas supply piping.

 

 

 

Read all of the instructions before starting the insta-

Electrical wiring.

 

 

 

llation. Follow these instructions carefully during the

Framing and finishing details.

 

installation to ensure maximum safety and benefit.

Whether optional accessories—devices such as a fan,

 

 

 

 

wall switch, or remote control—are desired.

 

 

WARNING

 

 

 

 

 

 

 

 

 

WARNING

 

 

Hearth & Home Technologies disclaims any

 

 

 

 

 

responsibility for, and the warranty will be voided

 

Keep appliance dry.

 

 

by, the following actions:

 

 

Installation and use of any damaged appliance or vent

 

Mold or rust may cause odors.

 

 

 

 

system component.

 

Water may damage controls.

 

 

 

 

Modification of the appliance or vent system.

 

 

 

 

 

 

 

 

 

 

Installation other than as instructed by Hearth & Home

B. Tools and Supplies Needed

 

 

Technologies.

Before beginning the installation be sure that the following

 

• Improper positioning of the gas logs or the glass door.

 

• Installation and/or use of any component part not approved

tools and building supplies are available.

 

 

 

by Hearth & Home Technologies.

 

 

 

 

 

 

Reciprocating saw

Framing material

 

Any such action may cause a fire hazard.

Pliers

 

Noncorrosive leak check solution

 

 

 

Hammer

 

Gloves

 

 

 

Phillips screwdriver

Framing square

 

 

 

Flat blade screwdriver

Electric drill and bits (1/4 in.)

 

 

 

Plumb line

 

Safety glasses

 

 

 

Level

 

1/2 - 3/4 inch length, #6 or #8 Self-drilling screws

ManometerVoltmeter

Tape measure

Caulking material (300ºF minimum continuous exposure rating)

6

Heat & Glo • Soho24B • 2137-900 Rev. P • 8/12

Image 6
Contents Model Soho24B What to do if you smell gasHot glass will cause burns Congratulations Homeowner Reference InformationTable of Contents Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsInstallation to ensure maximum safety and benefit Getting StartedTools and Supplies Needed Framing and Clearances Selecting Appliance LocationMantel Projections Constructing the Appliance Chase ClearancesTermination Locations Vent Termination Minimum ClearancesSee .4 for specific clearances Covered Alcove Applications Inches U.S.AUse of Elbows Vent Information and DiagramsVent Table Key Measuring StandardsTwo Elbows Vent DiagramsTop Vent Horizontal Termination One Elbow Minimum MaximumTop Vent Horizontal Termination Three Elbows V1 Min H1 Max V2 Min H2 MaxTop Vent Vertical Termination No Elbow V1 = 45 ft Max .72 m V1 = 3 ft Min mmV1 Minimum H1 Maximum V1 + Top Vent Vertical Termination Three Elbows V1 Minimum H1+ H2 Maximum V1+ V2 MinimumWall Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Combustible Wall PenetrationVertical Penetration Framing Pipe SLPInstall Attic Insulation Shield Flat Ceiling InstallationVaulted Ceiling Installation Appliance Preparation Top VentInstallation of Non-combustible Facing Material MaterialSecuring and Leveling the Appliance Proper Positioning, Leveling and Securing of aInstalling Vent Pipe Assemble Vent SectionsAssemble Slip Sections Secure the Vent SectionsInstall Decorative Ceiling Components Disassemble Vent SectionsInstall Metal Roof Flashing Assemble and Install Storm CollarInstall Vertical Termination Cap Install Decorative Wall ComponentsHeat Shield Requirements for Horizontal Termination Install Horizontal Termination Cap 17 Venting through the wallGas Pressures Gas InformationFuel Conversions Gas Connection Pressure Natural Gas PropaneHigh Altitude Installations Recommendation for Wire Electrical InformationJunction Box Installation GRN wire Ground attached To GRN screw with Inside boxFinishing Facing MaterialSee for combustible/non-combustible definitions Installation of Non-Combustible Facing Materials PaintingAccessories Appliance SetupClean the Appliance Remove Shipping MaterialsStone Placement Soho24B Positioning StonesNo Stones in this Area Removing Glass Assembly Glass AssemblyAir Shutter Setting Replacing Glass AssemblyOperating Instructions Before Lighting ApplianceLighting Instructions IPI Final inspection byFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Troubleshooting IntelliFire Ignition SystemSympton Possible Cause Corrective Action Symptom Possible Cause Corrective Action Maintenance Tasks Maintaining and Servicing ApplianceInspect Maintenance Tasks Recommend addition of screen if one is not presentReference Materials Appliance Dimension DiagramAppliance Dimensions Table Location Inches MillimeterVent Components Diagrams SL Series Components B. Vent Components Diagrams Assembly 12-1/2 356 mm 330 mm305 mm 318 mmAt Depot Service PartsStocked 24 x 24 Direct Vent Fireplace#11 IPI Valve Assembly SOHO24B-ONYX No longer availableLimited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Contact Information