INSTALLATION
Horizontal Venting with Three (3) 90o Elbows
One 90o elbow = Two 45o elbows.
Option V | H | V + V1 H + H1 |
A)2' Min. 1' Max. 3' Min. 4' Max.
B)3' Min. 2' Max. 4' Min. 5' Max.
C)4' Min. 3' Max. 6' Min. 6' Max.
D)5' Min. 4' Max. 8' Min. 7' Max.
E)6' Min. 5 Max. 10' Min. 8' Max.
F)7' Min. 6' Max. 12' Min.
With these options, max. total pipe length is 30 feet with min. of 12 feet total vertical and max. 9 feet total horizontal.
Please note min. 1
foot between 90o 9' Max.
elbows is required.
Vertical Venting with Two (2) 90o Elbows
One 90o elbow = Two 45o elbows.
Option V | H | V + V1 With these options, max. total |
A)1' Min. 4' Max. 2' Min. pipe length is 30 feet with min.
B) | 2' Min. | 5' Max. | 3' Min. | of 6 feet total vertical and max. |
8 feet total horizontal. | ||||
C) | 3' Min. | 6' Max. | 4' Min. | Please note min. 1 foot |
D) | 4' Min. | 7' Max. | 5' Min. | between 90o elbows is re- |
E) | 5' Min. | 8' Max. | 6' Min. | quired. |
Vertical Venting with Two (2) 90o Elbows
One 90o elbow = Two 45o elbows.
Option | H + H1 | V | With these options, max. total |
|
|
| |
A) | 2' Max. | 2' Min. pipe length is 30 feet with min. | |
B) | 3' Max. | 3' Min. of 6 feet total vertical and max. |
C)4' Max. 4' Min. 6 feet total horizontal.
Please note min. 1 foot
D)5' Max. 5' Min. between 90o elbows is
E)6' Max. 6' Min. required.
Foradditionalverticalventingwith2 x 90o elbows, refer to page 15.