Regency P33-NG3 Thermopile Thermocouple, Glass Gasket, Door Glass, Flush Glass Replacement

Page 39
MAINTENANCE
Bay Glass Replacement

THERMOPILE/

THERMOCOUPLE

1)Open the bottom louvers.

2)Loosen the thermocouple or thermopile with a 7/16" wrench.

3)Disconnect thermocouple by loosening nut from the valve with a 9mm wrench. Dis- connect thermopile by loosening 2 screws marked TP on the valve.

4)Drop the thermocouple or thermopile down from the bracket and pull it out of the unit.

5)Reinstall the new ones in reverse order.

GLASS GASKET

If the glass gasket requires replacement use 5/8" fl at glass gasket for the Bay Front (Part

#936-243) and a tadpole glass gasket for the Flush Front (Part # 936-155).

DOOR GLASS

Your Regency stove is supplied with high temperature, 5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will produce. If your glass requires clean- ing, we recommend using an approved glass cleaner available at all authorized dealers. Do not use abrasive materials. Do not clean the glass when hot.

In the event that you break your glass by impact, purchase your replacement from an authorized Regencydealeronly,andfollowourstep-by-step instructions for replacement.

WARNING: Do not operate the appliance with the glass panels removed, cracked or broken. Replacement of the glass panels should be done by a licensed or qualified service person.

Caution:Weargloveswhenremoving damaged or broken glass.

Flush Glass Replacement

Remove the fl ush door front. Remove the 4

1)

Remove the door from the unit and place on

glass clips from each corner. Slide in the new

 

 

a soft surface to prevent scratching.

replacement glass. Push the 4 glass clips back

 

 

 

 

 

 

 

onto the frame. The glass must have gasket-

2)

Remove the nuts holding the glass clips in

ing around it.

 

 

place and remove.

 

 

 

 

3)

Replace the glass. The glass must have

 

 

 

 

 

 

gasketing around it.

 

 

 

 

5)

Reversetheprevioussteps,replacetheglass

 

 

 

 

 

 

clips and fasten with the nuts but do not over

 

 

 

 

 

 

 

 

 

 

 

 

tighten, as this can break the glass.

 

 

 

 

 

 

 

 

 

 

6)

Replace door on the stove and check the

 

 

 

 

 

 

seal.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Regency P33-3 Zero Clearance Direct Vent Gas Fireplace

Image 39
Contents P33-3 Zero Clearance To the New Owner Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Safety Label Before YOU Start InstallationGeneral Safety Information Save These InstructionsDuct System Option Installation ChecklistUnit Dimensions Locating Your GAS StoveFire hazard is an extreme risk if these Clearancescombustible MantelsMantel LEG Clearances Clearances are not adhered toVertical Termination or Vertical Rise with Horizontal Framing and FinishingRear Termination Simpson Dura-Vent Minimum ClearancesTop Facing Support Side Nailing Strips Unit Assembly Prior to InstallationTop Standoff Assembly Venting IntroductionVent terminal Air supply outlet VentRegency Direct Vent System Flex Horizontal Terminations only For Regency Direct Vent System Flex Installation ProceduresThickness inches Required inches Flat Wall InstallationRigid Pipe Venting Systems Max. Wall Vent LengthRigid Pipe Venting Components List Description Simpson Dura-Vent SelkirkDirect VentGS R Direct-Temp TM Propane & Natural Gas Rigid Pipe Venting Arrangements Vertical TerminationsInstallation Regency Direct Vent System Flex Rigid Pipe Venting Arrangements Horizontal TerminationsHorizontal Venting with Two 2 90o Elbows Horizontal Venting with Three 3 90o ElbowsOption + H1 + V1 With these options, max. total Vertical Venting with Two 2 90o ElbowsOption + V1 H + H1 OptionVertical Venting with Three 3 90o Elbows Alternate Approved Caps Vertical Termination With CO-LINEAR Flex SystemRequired Parts DescriptionInstallation Horizontal Installations Below Grade Snorkel InstallationSnorkel Terminations Vertical Termination GAS Line InstallationT. Valve Description Pilot AdjustmentGAS Pipe Pressure Testing High ElevationConversion Kit Contains BracketBracket LOG SET InstallationOptional Brick Panels Notch5th Grate Tab Standard Flush DoorOptional Flush Trim CutoutBay louvers Must be used With the Bay glass option Flush LouversDouble Screen Door Optional BAY DoorBurner ON/OFF Control box BAY LouversFlush Louver Top Heat Shield Bay Louver Top Heat ShieldFull Screen Front Cut-Out Oblong Hole Top Flange BottomCut-Outs Top Grill Hinge Location Bottom GrillThermostat Wire Table Optional Wall SwitchDo not cut the ground terminal off under any circumstances Wiring DiagramSecure the 2 boxes together With one screw Installing the Optional FANShut the power off Diagram Secure left side with 2 screwsCopy of the Lighting Plate Instructions Operating InstructionsOperating Instructions Lighting ProcedureShutdown Procedure Aeration AdjustmentNormal Operating Sounds GAS Appliances MaintenanceMaintenance Instructions LOG ReplacementDoor Glass Flush Glass ReplacementThermopile Thermocouple Glass GasketShut off the gas supply Installing ValveDiagram 3 Lift out Valve Tray Assembly Removing ValveDescription Parts ListParts List Part Description Burner & Log AssemblyFlush Front & Louvers Bay Front & Louvers Regency P33-3 Zero Clearance Direct Vent Gas Fireplace Conditions WarrantyInstaller Please complete the following information