Regency P33-NG3, P33-LP3 installation manual Parts List, Description

Page 41

PARTS LIST

Main Assembly

 

Part #

Description

 

Part #

Description

1)

948-247

Door Handle

 

432-928

Brick Panel Set - Standard

2)

*

Thermodisc Bracket

 

432-901

Brick Panel Set - Standard Brown

 

 

 

 

432-902

Brick Panel Set - Standard Red

7)

910-428

Duplex Receptacle

 

432-903

Brick Panel Set - Herringbone

8)

910-429

Box - Receptacle

 

 

Brown

 

9)

910-430

Cover - Receptacle

 

432-904

Brick Panel Set - Herringbone Red

10)

904-687

Clamp Connector

33)

*

Brick Panel - Rear

13)

948-045

#12 Jack Chain

34)

*

Brick Panel - Left Side

14)

948-115

Door Extension Spring

35)

*

Brick Panel - Right Side

 

 

 

36)

*

Brick Panel - Top

16)

*

Thermodisc Top

37)

430-056

Brick Clip - Top

17)

*

Thermodisc Box Base

38)

430-057

Brick Clip - Bottom

19)

430-129

Receptacle Box Mount

 

 

 

 

 

 

 

 

432-945

Herringbone Brick Panel Set

20)

430-031

Top Nailing Strip

 

 

(Optional)

21)

430-032

Side Nailing Strip

 

902-359

Brick Panel - Rear

22)

433-017

Firebox Baffle

 

902-358

Brick Panel - Left Side

23)

433-011F

Top Standoff

 

902-360

Brick Panel - Right Side

24)

511-044

Standoff - Side

 

902-361

Brick Panel - Top

 

790-091

Standoff - Rear

 

 

 

 

26)

*

Louver Hold Down

 

 

 

 

27)

*

Outer Flue Collar

 

432-917

Fan Assembly (120 Volts)

28)

*

Inner Flue Collar Assembly

 

 

Optional

30)

*

Gasket - Flue Collar

42)

910-331/P

Fan Motor (120 Volts)

31)

*

Flue Mounting Plate

 

432-966

Fan Switch Assy (120 Volts)

 

 

 

43)

910-813

Power

Cord (120 Volts)

 

 

 

46)

910-330

Fan Speed Control

 

 

 

47)

904-586

Knob - Speed Control

Part # Description

49)910-142 Thermodisc - Fan Auto ON/OFF

50)904-713 U-Clip at Louver

432-967 Burner On/Off Switch Assy

63)910-241 Switch - Burner On/Off

910-899 Wire Harness - Valve to Burner

946-556 Optional Heat Wave Duct Kit

89)946-004 Junction Box

90)946-000 Round Duct Adaptor

91)946-002 Round to Oval Adaptor

92)946-001 Oval Duct Adaptor

93)946-007 Angle Bracket

94)946-517/P Fan Assembly - HeatWave Option

95)946-006 Grill Plate - White

96)946-005 Wall Adaptor Plate - White

97)910-417 Knob - White

98)910-366 Switch Cover Plate - White

99)910-412 Fan Speed Controller

100)910-367 Box - Plastic Switch Receptacle

102) 946-010

Flexible Air Duct

946-038

Insulation 6" dia. x 24"

104) 690-022F

Cover Plate

510-994

Dura-Vent Adaptor

918-262

Manual

431-969

Conversion Kit - NG to LP

Regency P33-3 Zero Clearance Direct Vent Gas Fireplace

Image 41
Contents P33-3 Zero Clearance To the New Owner Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Safety Label General Safety Information InstallationSave These Instructions Before YOU StartUnit Dimensions Installation ChecklistLocating Your GAS Stove Duct System OptionMantel LEG Clearances Clearancescombustible MantelsClearances are not adhered to Fire hazard is an extreme risk if theseRear Termination Framing and FinishingSimpson Dura-Vent Minimum Clearances Vertical Termination or Vertical Rise with HorizontalTop Standoff Assembly Unit Assembly Prior to InstallationVenting Introduction Top Facing Support Side Nailing StripsVent terminal Air supply outlet VentRegency Direct Vent System Flex Horizontal Terminations only For Regency Direct Vent System Flex Installation ProceduresRigid Pipe Venting Systems Flat Wall InstallationMax. Wall Vent Length Thickness inches Required inchesDirect VentGS R Direct-Temp TM Rigid Pipe Venting Components ListDescription Simpson Dura-Vent Selkirk Propane & Natural Gas Rigid Pipe Venting Arrangements Vertical TerminationsInstallation Regency Direct Vent System Flex Rigid Pipe Venting Arrangements Horizontal TerminationsOption + H1 Horizontal Venting with Two 2 90o ElbowsHorizontal Venting with Three 3 90o Elbows Option + V1 H + H1 Vertical Venting with Two 2 90o ElbowsOption + V1 With these options, max. totalVertical Venting with Three 3 90o Elbows Required Parts Vertical Termination With CO-LINEAR Flex SystemDescription Alternate Approved CapsInstallation Snorkel Terminations Horizontal InstallationsBelow Grade Snorkel Installation Vertical Termination GAS Line InstallationGAS Pipe Pressure Testing Pilot AdjustmentHigh Elevation T. Valve DescriptionConversion Kit Contains Optional Brick Panels LOG SET InstallationNotch BracketBracketOptional Flush Trim Standard Flush DoorCutout 5th Grate TabDouble Screen Door Flush LouversOptional BAY Door Bay louvers Must be used With the Bay glass optionFlush Louver Top Heat Shield BAY LouversBay Louver Top Heat Shield Burner ON/OFF Control boxCut-Outs Full Screen FrontCut-Out Oblong Hole Top Flange Bottom Top Grill Hinge Location Bottom GrillThermostat Wire Table Optional Wall SwitchDo not cut the ground terminal off under any circumstances Wiring DiagramShut the power off Installing the Optional FANDiagram Secure left side with 2 screws Secure the 2 boxes together With one screwCopy of the Lighting Plate Instructions Operating InstructionsShutdown Procedure Lighting ProcedureAeration Adjustment Operating InstructionsMaintenance Instructions MaintenanceLOG Replacement Normal Operating Sounds GAS AppliancesThermopile Thermocouple Flush Glass ReplacementGlass Gasket Door GlassDiagram 3 Lift out Valve Tray Assembly Installing ValveRemoving Valve Shut off the gas supplyDescription Parts ListParts List Part Description Burner & Log AssemblyFlush Front & Louvers Bay Front & Louvers Regency P33-3 Zero Clearance Direct Vent Gas Fireplace Conditions WarrantyInstaller Please complete the following information