Regency P33-LP3, P33-NG3 Removing Valve, Installing Valve, Shut off the gas supply

Page 40

MAINTENANCE

REMOVING VALVE

1)Shut off the gas supply.

2)Remove the louvers (and bay door if it is on).

3)Open the fl ush door and remove the door.

4)Remove the logs.

5)Remove the burner/grate assembly by removing the two Phillips head screws and then lift the burner assembly out.

10)Undo the pilot tube from the valve with a 7/16" wrench.

INSTALLING VALVE

1)

Attach the valve to the valve bracket with

 

the 4 (m5x8 metric) screws provided.

2)

Reconnect the "gas out" fl are fi tting with

 

an 11/16" wrench.

3)

Reconnect the "gas out" fl are nut with a

 

13/16" wrench.

4)

Install piezo ignitor push button assembly

 

and reconnect wire.

5)

Reconnectthequickdropoutthermocouple

 

nut with a 9mm wrench.

Diagram 3: Lift out Valve Tray Assembly

6) Reconnect the pilot tube nut with a 7/16"

wrench.

7) Scrapeofftheoldgasketfromthefloorofthe

fi rebox and from the valve tray assembly.

8)Install a new gasket and reinstall the valve tray assembly.

Diagram 1: Remove the left and right screws and then lift out the burner/grate assembly.

6)Remove the rear log stand by removing the 2 screws.

7)Disconnect the inlet gas line. See diagram 2.

8)Disconnect the 2 TP wires and the 2 TH wires from the valve.

9)Remove the 10 Phillips head screws secur- ingthevalvetrayassemblyinplace(diagram

2)and then lift the entire assembly out

(diagram 3).

screws

11)Undo the quick drop out thermocouple nut on the valve with a 9mm (metric) wrench.

12)Remove the Piezo igniter wire and push button assembly.

13)Undo the "gas out" fl are nut with a 13/16" wrench.

14)Undo the "gas out" fl are fi tting with an 11/16" wrench.

15)Remove the 4 Phillips head screws from the sides of the valve bracket and remove valve.

Hint: If you are using black pipe, ensure that there is a union by the valve, otherwise removal will be almost impossible.

Rear Log Stand

Note: Failure to install a new gasket may severely affect the appliance per- formance.

9)Reinstall the 10 hold down screws.

10)Hook up the 2 TP and 2 TH wires to the appropriate connections on the valve.

11)Reinstall the front log stand.

12)Install Burner/grate assembly.

13)Hook up the gas line and check for gas leaks with a soap and water solution or a gas leak detector. (Do not use open fl ame for leak testing.)

14)Fire up the unit temporarily.

15)Check the manifold pressure.

16)Reinstall the logs and brick panels as needed.

17)Close the door and replace the louvers.

18)Fire up the unit again and check for proper fl ame appearance and glow on logs.

screwsValve Tray Assembly Diagram 2: Rear Log Stand & Valve Tray Assembly

Regency P33-3 Zero Clearance Direct Vent Gas Fireplace

Image 40
Contents P33-3 Zero Clearance Information for MOBILE/MANUFACTURED Homes After First Sale To the New OwnerTable of Contents Safety Label Installation General Safety InformationSave These Instructions Before YOU StartInstallation Checklist Unit DimensionsLocating Your GAS Stove Duct System OptionClearancescombustible Mantels Mantel LEG ClearancesClearances are not adhered to Fire hazard is an extreme risk if theseFraming and Finishing Rear TerminationSimpson Dura-Vent Minimum Clearances Vertical Termination or Vertical Rise with HorizontalUnit Assembly Prior to Installation Top Standoff AssemblyVenting Introduction Top Facing Support Side Nailing StripsVent Vent terminal Air supply outletRegency Direct Vent System Flex Horizontal Terminations only Installation Procedures For Regency Direct Vent System FlexFlat Wall Installation Rigid Pipe Venting SystemsMax. Wall Vent Length Thickness inches Required inchesDescription Simpson Dura-Vent Selkirk Rigid Pipe Venting Components ListDirect VentGS R Direct-Temp TM Rigid Pipe Venting Arrangements Vertical Terminations Propane & Natural GasInstallation Rigid Pipe Venting Arrangements Horizontal Terminations Regency Direct Vent System FlexHorizontal Venting with Three 3 90o Elbows Horizontal Venting with Two 2 90o ElbowsOption + H1 Vertical Venting with Two 2 90o Elbows Option + V1 H + H1Option + V1 With these options, max. totalVertical Venting with Three 3 90o Elbows Vertical Termination With CO-LINEAR Flex System Required PartsDescription Alternate Approved CapsInstallation Below Grade Snorkel Installation Horizontal InstallationsSnorkel Terminations GAS Line Installation Vertical TerminationPilot Adjustment GAS Pipe Pressure TestingHigh Elevation T. Valve DescriptionConversion Kit Contains LOG SET Installation Optional Brick PanelsNotch BracketBracketStandard Flush Door Optional Flush TrimCutout 5th Grate TabFlush Louvers Double Screen DoorOptional BAY Door Bay louvers Must be used With the Bay glass optionBAY Louvers Flush Louver Top Heat ShieldBay Louver Top Heat Shield Burner ON/OFF Control boxCut-Out Oblong Hole Top Flange Bottom Full Screen FrontCut-Outs Hinge Location Bottom Grill Top GrillOptional Wall Switch Thermostat Wire TableWiring Diagram Do not cut the ground terminal off under any circumstancesInstalling the Optional FAN Shut the power offDiagram Secure left side with 2 screws Secure the 2 boxes together With one screwOperating Instructions Copy of the Lighting Plate InstructionsLighting Procedure Shutdown ProcedureAeration Adjustment Operating InstructionsMaintenance Maintenance InstructionsLOG Replacement Normal Operating Sounds GAS AppliancesFlush Glass Replacement Thermopile ThermocoupleGlass Gasket Door GlassInstalling Valve Diagram 3 Lift out Valve Tray AssemblyRemoving Valve Shut off the gas supplyParts List DescriptionParts List Burner & Log Assembly Part DescriptionFlush Front & Louvers Bay Front & Louvers Regency P33-3 Zero Clearance Direct Vent Gas Fireplace Warranty ConditionsInstaller Please complete the following information