Regency P33-LP3, P33-NG3 Installation Checklist, Unit Dimensions, Locating Your GAS Stove

Page 6

INSTALLATION

INSTALLATION

CHECKLIST

1)Locate appliance

a)Room location, page 6

b)Clearances to Combustibles, page 7

c)Mantle Clearances, page 7

d)Framing & Finishing Requirements, page 8

e)Venting Requirements, pages 10 to 15.

2)Assemble Top Facing Support and Side Nailing Strips, page 9. (NOTE: must be done before installing unit into fi replace.)

3)Install vent, pages 10 to 24.

4)Make gas and electrical connections. Test the pilot. Must be as per diagram. Page 25. Convert to Propane if desired, page 26.

5)Install brick panels (optional), page 27.

6)Install logs and embers and rockwool where indicated on page 27.

7)Install Flush Door Front (Standard) and optional Flush Gold Trim, page 28.

8)Install optional Double Screen Door, page 29.

9)Install Optional Bay Front and optional Bay Gold Trim, page 29.

10)Install Louvers (Flush or Bay), pages 28 and 29.

11)InstalloptionalWallSwitch,RemoteControl, or Wall Thermostat, page 33.

11)Install Optional Fan, page 35.

13)Final check.

UNIT DIMENSIONS

4) The P33-3 can be installed in a recessed position or framed out into the room as in A, B, C, D. See Diagram 1.

5) This appliance is Listed for bedroom instal- lations when used with a Listed Millivolt Thermostat. Some areas may have further requirements, check local codes before installation.

6) The P33-3 Direct Vent Gas Fireplace is ap- proved for alcove installations, which meet the clearances listed on this page.

7) We recommend that you plan your instal- lation on paper using exact measurements for clearances and fl oor protection before actually installing this appliance. Have a qualifiedinspector,dealer,orinstallerreview your plans before installation.

Note: For vent terminations see page 10.

Diagram 1

A) Flat on Wall

B) Flat on Wall Corner

C) Recessed into Wall/Alcove

Before leaving this unit with the customer, the installer must ensure that the appliance is fi r- ing correctly and operation fully explained

to customer.

This includes:

1)Clocking the appliance to ensure the correct fi ring rate (rate noted on label) after burning appliance for 15 minutes.

2)Ifrequired,adjustingtheprimaryairtoensure that the fl ame does not carbon. First allow the unit to burn for 15-20 min. to stabilize.

CAUTION: Any alteration to the product that causes sooting or carboning that results in damage is not the responsibility of the manufacturer.

LOCATING YOUR

GAS STOVE

1)When selecting a location for your stove, ensure that the clearances outlined on this page are met.

2)Provide adequate clearances for servic- ing.

3)The appliance must be installed on a fl at, solid, continuous surface (e.g. wood, metal, concrete).This may be the fl oor, or raised up on a platform to enhance its visual impact. If the appliance is going to be installed on carpeting, combustible linoleum tile or other combustible material other than wood fl oor- ing, the appliance must be installed on a metal or wood panel extending the full width and depth of the appliance.

DUCT SYSTEM

OPTION

KIT #946-556

The HeatWave Air Duct Kit increases the ef- fectivenessofyourfireplacebydispersingwarm air from the fi replace to remote locations in the same room or other rooms in your home.

Up to two kits may be installed on the fi replace. Please Note: Only 1 HeatWave kit may be operated at one time. This includes the internal blower option as well.

Regency P33-3 Zero Clearance Direct Vent Gas Fireplace

Image 6
Contents P33-3 Zero Clearance Information for MOBILE/MANUFACTURED Homes After First Sale To the New OwnerTable of Contents Safety Label Save These Instructions InstallationGeneral Safety Information Before YOU StartLocating Your GAS Stove Installation ChecklistUnit Dimensions Duct System OptionClearances are not adhered to Clearancescombustible MantelsMantel LEG Clearances Fire hazard is an extreme risk if theseSimpson Dura-Vent Minimum Clearances Framing and FinishingRear Termination Vertical Termination or Vertical Rise with HorizontalVenting Introduction Unit Assembly Prior to InstallationTop Standoff Assembly Top Facing Support Side Nailing StripsVent Vent terminal Air supply outletRegency Direct Vent System Flex Horizontal Terminations only Installation Procedures For Regency Direct Vent System FlexMax. Wall Vent Length Flat Wall InstallationRigid Pipe Venting Systems Thickness inches Required inchesRigid Pipe Venting Components List Description Simpson Dura-Vent SelkirkDirect VentGS R Direct-Temp TM Rigid Pipe Venting Arrangements Vertical Terminations Propane & Natural GasInstallation Rigid Pipe Venting Arrangements Horizontal Terminations Regency Direct Vent System FlexHorizontal Venting with Two 2 90o Elbows Horizontal Venting with Three 3 90o ElbowsOption + H1 Option Vertical Venting with Two 2 90o ElbowsOption + V1 H + H1 + V1 With these options, max. totalVertical Venting with Three 3 90o Elbows Description Vertical Termination With CO-LINEAR Flex SystemRequired Parts Alternate Approved CapsInstallation Horizontal Installations Below Grade Snorkel InstallationSnorkel Terminations GAS Line Installation Vertical TerminationHigh Elevation Pilot AdjustmentGAS Pipe Pressure Testing T. Valve DescriptionConversion Kit Contains Notch LOG SET InstallationOptional Brick Panels BracketBracketCutout Standard Flush DoorOptional Flush Trim 5th Grate TabOptional BAY Door Flush LouversDouble Screen Door Bay louvers Must be used With the Bay glass optionBay Louver Top Heat Shield BAY LouversFlush Louver Top Heat Shield Burner ON/OFF Control boxFull Screen Front Cut-Out Oblong Hole Top Flange BottomCut-Outs Hinge Location Bottom Grill Top GrillOptional Wall Switch Thermostat Wire TableWiring Diagram Do not cut the ground terminal off under any circumstancesDiagram Secure left side with 2 screws Installing the Optional FANShut the power off Secure the 2 boxes together With one screwOperating Instructions Copy of the Lighting Plate InstructionsAeration Adjustment Lighting ProcedureShutdown Procedure Operating InstructionsLOG Replacement MaintenanceMaintenance Instructions Normal Operating Sounds GAS AppliancesGlass Gasket Flush Glass ReplacementThermopile Thermocouple Door GlassRemoving Valve Installing ValveDiagram 3 Lift out Valve Tray Assembly Shut off the gas supplyParts List DescriptionParts List Burner & Log Assembly Part DescriptionFlush Front & Louvers Bay Front & Louvers Regency P33-3 Zero Clearance Direct Vent Gas Fireplace Warranty ConditionsInstaller Please complete the following information