INSTALLATION

BAY LOUVERS

1)Remove fl ush louver top heat shield by removing the 4 screws.

4)Install bottom louver by sliding the two bracket clips into the brackets located underneath the bay door. Secure with 1 screw into each Bottom Louver Mounting Bracket as per diagram below. Use the bottom hole in the bracket.

5)Slide the valve extension knobs onto the valve knobs. Match the correct ext. knob with the valve knob.

Flush Louver Top

Heat Shield

2) Install the bay louver top heat shield and secure with 4 screws.

6) Open the bottom louver. Pull the Burner ON/OFF control box from inside the bottom of the fi replace and position the slots in the bracket over the 2 screws on the left side of the bottom louver. Push down to lock into place. Tighten the screws.

Bay Louver Top

Heat Shield

3)Install top louver by sliding the two bracket clips into the brackets located on top of the bay door. See below. The fi tted louver leaves a small gap between faceplate bottom and louver top.

Burner ON/OFF

control box

Regency P33-3 Zero Clearance Direct Vent Gas Fireplace

Image 30
Contents P33-3 Zero Clearance Information for MOBILE/MANUFACTURED Homes After First Sale To the New OwnerTable of Contents Safety Label Save These Instructions InstallationGeneral Safety Information Before YOU StartLocating Your GAS Stove Installation ChecklistUnit Dimensions Duct System OptionClearances are not adhered to Clearancescombustible MantelsMantel LEG Clearances Fire hazard is an extreme risk if theseSimpson Dura-Vent Minimum Clearances Framing and FinishingRear Termination Vertical Termination or Vertical Rise with HorizontalVenting Introduction Unit Assembly Prior to InstallationTop Standoff Assembly Top Facing Support Side Nailing StripsVent Vent terminal Air supply outletRegency Direct Vent System Flex Horizontal Terminations only Installation Procedures For Regency Direct Vent System FlexMax. Wall Vent Length Flat Wall InstallationRigid Pipe Venting Systems Thickness inches Required inchesRigid Pipe Venting Components List Description Simpson Dura-Vent SelkirkDirect VentGS R Direct-Temp TM Rigid Pipe Venting Arrangements Vertical Terminations Propane & Natural GasInstallation Rigid Pipe Venting Arrangements Horizontal Terminations Regency Direct Vent System FlexHorizontal Venting with Two 2 90o Elbows Horizontal Venting with Three 3 90o ElbowsOption + H1 Option Vertical Venting with Two 2 90o ElbowsOption + V1 H + H1 + V1 With these options, max. totalVertical Venting with Three 3 90o Elbows Description Vertical Termination With CO-LINEAR Flex SystemRequired Parts Alternate Approved CapsInstallation Horizontal Installations Below Grade Snorkel InstallationSnorkel Terminations GAS Line Installation Vertical TerminationHigh Elevation Pilot AdjustmentGAS Pipe Pressure Testing T. Valve DescriptionConversion Kit Contains Notch LOG SET InstallationOptional Brick Panels BracketBracketCutout Standard Flush DoorOptional Flush Trim 5th Grate TabOptional BAY Door Flush LouversDouble Screen Door Bay louvers Must be used With the Bay glass optionBay Louver Top Heat Shield BAY LouversFlush Louver Top Heat Shield Burner ON/OFF Control boxFull Screen Front Cut-Out Oblong Hole Top Flange BottomCut-Outs Hinge Location Bottom Grill Top GrillOptional Wall Switch Thermostat Wire TableWiring Diagram Do not cut the ground terminal off under any circumstancesDiagram Secure left side with 2 screws Installing the Optional FANShut the power off Secure the 2 boxes together With one screwOperating Instructions Copy of the Lighting Plate InstructionsAeration Adjustment Lighting ProcedureShutdown Procedure Operating InstructionsLOG Replacement MaintenanceMaintenance Instructions Normal Operating Sounds GAS AppliancesGlass Gasket Flush Glass ReplacementThermopile Thermocouple Door GlassRemoving Valve Installing ValveDiagram 3 Lift out Valve Tray Assembly Shut off the gas supplyParts List DescriptionParts List Burner & Log Assembly Part DescriptionFlush Front & Louvers Bay Front & Louvers Regency P33-3 Zero Clearance Direct Vent Gas Fireplace Warranty ConditionsInstaller Please complete the following information