Regency L676-LP1 Installation, Burner Tube, Burner Orifi ce, NOTE Once the unit has been installed

Page 29
INSTALLATION

 

INSTALLATION

 

 

6) Remove the burner tube by removing the 2 10) Re-install the pilot cap.

13) Remove NG modulating regulator by

screws.

undoing 3 screws and replace with LP

11) Undo the center wire clip on the side of the

modulating regulator.

fi rebox.

 

INSTALLATION

Burner Tube

7)Remove the burner orifice with a 1/2" wrench. Use another wrench to hold onto the elbow behind the orifi ce. Replace the NG burner orifi ce with LP orifi ce #51.

Burner Orifi ce

8)Pull off the pilot cap to expose the pilot orifi ce.

9)Remove the NG pilot orifice with the 5/32 Allen Key and replace with LP pilot orifi ce.

12)Unplug the wire harness that connects the modulating coil to the receiver.

14)Install the enclosed identifi cation label to the valve body where it can be easily seen.

15)Attach the LP conversion decal near or on top of the serial no. decal.

16)Replace yellow "Natural Gas" label with red "Propane" label.

17)Adjust the burner aeration setting to the LP setting (5/16") and re-install the burner tube.

18)Re-install the grate.

19)Re-install the burner orifi ce cover plate.

20)Re-install the glass door.

21)Re-install the front cover plate

22)Continue with completing unit installation.

NOTE: Once the unit has been installed;

a)Turn on the gas supply and check for gas leaks.

b)Check the inlet and outlet pressures.

c)Check operation of fl ame control using the remote control.

d)Check for proper fl ame appearance.

Installer Notice:

This instructions must be left with the appliance.

Regency® L676-1 Direct Vent Gas Fireplace

29

Image 29
Contents LIBERTY L676-1Gas Fireplace MANUFACTURED MOBILE HOME REQUIREMENTS CongratulationsSAFETY LABEL TABLE OF CONTENTSINSTALLATION WARRANTYINSTALLATION SAFETY LABELINSTALLATION REQUIREMENTSMA Code - CO Detector 5.08: Modifications to NFPA-54,ChapterRegency L676-1Direct Vent Gas Fireplace UNIT DIMENSIONSINSTALLATION GENERAL SAFETY INFORMATION INSTALLATIONINSTALLATION CHECKLIST INSTALLATIONINSTALLATION INSTALLATIONDiagram HEAT RELEASE KITCLEARANCES INSTALLATIONClearance to Combustibles from Minimum Clearance from Top of Front FacingINSTALLATION INSTALLATIONMANTEL CLEARANCES MANTEL LEG CLEARANCESINSTALLATION INSTALLATIONDiagram Diagram DiagramUNIT ASSEMBLY PRIOR TO INSTALLATION INSTALLATIONINSTALLATION FINISHING TEMPLATEINSTALLATION INSTALLATIONVENT RESTRICTOR POSITION Vent Restrictor PlateINSTALLATION INSTALLATIONEXTERIOR VENT TERMINATION REQUIREMENTS Minimum Clearance RequirementsINSTALLATION INSTALLATIONVENTING ARRANGEMENTS FPI Kit #INSTALLATION INSTALLATIONWhen using Rigid Vent other than RIGID PIPE VENTING SYSTEMSINSTALLATION INSTALLATION5” X 8” RIGID PIPE CROSS REFERENCE CHART Regency L676-1Direct Vent Gas Fireplace INSTALLATIONINSTALLATION INSTALLATION INSTALLATIONVENT RESTRICTOR SETTING VENTING ARRANGEMENTSINSTALLATION INSTALLATIONHorizontal Venting with Two 2 90o Elbows Horizontal Venting with Three 3 90o ElbowsINSTALLATION INSTALLATIONVENT RESTRICTOR SETTING Vertical Venting with Three 3 90o ElbowsINSTALLATION INSTALLATIONVENTING ARRANGEMENTS ALLOWABLE VERTICAL TERMINATIONSUNIT INSTALLATION WITH HORIZONTAL TERMINATION INSTALLATIONINSTALLATION DiagramUNIT INSTALLATION WITH VERTICAL TERMINATION INSTALLATIONINSTALLATION DiagramUNIT INSTALLATION INSTALLATIONINSTALLATION ASTROCAP XL DIMENSIONS 946-623/PPILOT ADJUSTMENT INSTALLATIONGAS LINE INSTALLATION TESTINGAERATION ADJUSTMENT INSTALLATIONWIRING DIAGRAM INSTALLATIONINSTALLATION INSTALLATIONCONVERSION KIT #522-969FROM NG TO LP LP Conversion Kit ContainsINSTALLATION INSTALLATIONNOTE Once the unit has been installed Burner TubeBRICK PANEL INSTALLATION INSTALLATIONINSTALLATION Diagram Right Side Rod with Screen RemovedINSTALLATION INSTALLATIONBurner Orifi ce Cover Plate Diagram DiagramLOG SET INSTALLATION INSTALLATIONINSTALLATION Log kit # 522-930contains the following piecesINSTALLATION INSTALLATION5 Fit log A into the pins on the log tray 7 Fit log E into the pin at the center of log AINSTALLATION INSTALLATIONF BA C 1st Grate PostINSTALLATION INSTALLATIONCompleted Log Set Installation E F A B CMESH PULL SCREEN INSTALLATION INSTALLATIONINSTALLATION Left Side Rod Right Side RodINSTALLATION OPTIONAL ANDIRON INSTALLATIONFinal Installation L900-1 Log GMATCHING REMOTE CONTROL & RECEIVER CODE OPERATING INSTRUCTIONSLIGHTING PROCEDURE SHUTDOWN PROCEDURENORMAL OPERATING SOUNDS OF GAS APPLIANCES OPERATING INSTRUCTIONSCOPY OF LIGHTING PLATE INSTRUCTIONS DO NOT REMOVE THIS INSTRUCTION PLATEMAINTENANCE INSTRUCTIONS MAINTENANCELOG REPLACEMENT GENERAL VENT MAINTENANCEDC SPARK BOX BATTERY REPLACEMENT MAINTENANCEDC SPARK BOX REPLACEMENT MAINTENANCEVALVE TRAY REPLACEMENT MAINTENANCEMAINTENANCE Latch Location LatchMAINTENANCE MAINTENANCEDC Spark Box DC Spark BoxMAIN ASSEMBLY PARTS LISTPARTS LIST Part #PARTS LIST PARTS LISTBURNER & LOG ASSEMBLY PARTS LISTPARTS LIST Part #The Warranty: Limited Lifetime WARRANTYConditions ExclusionsSee the inside back cover for details