Regency L676-NG1, L676-1, L676-LP1 Unit Assembly Prior To Installation, Finishing Template

Page 12
UNIT ASSEMBLY

INSTALLATION

INSTALLATION

UNIT ASSEMBLY

PRIOR TO

INSTALLATION

The Top Facing Support, the Side Nailing Strips and the 2 Top Standoffs must be correctly positioned and attached to the top before unit is slipped into position.

SIDE NAILING STRIPS

The side nailing strips come attached to the unit. There are 2 plates on each side, one on the top and bottom that can be folded out as required.

TOP STANDOFF ASSEMBLY

The top standoffs are shipped in a flat position and must be folded into shape and attached.

1)Remove the standoffs from the fireplace top.

2) Take each standoff and bend into the correct shape. Bend up at the bend lines until the screw holes in the standoff and the pre- punched screw holes on the fireplace top line up.

3) Attach the standoff securely to the top with 2 screws per standoff (on opposite corners).

Side Nailing Strips shown folded out.

FINISHING TEMPLATE

In order to maintain a clean face; the L676-1 allows for a 1/8” in overlap of finishing material, such as rock or tile, on both the left and right hand sides of the unit (top and bottom sides do not allow for an overlap), this overlap must not be exceeded or the glass door will no longer open properly.

Non-combustible wall board is installed up to the flanges on all sides of the unit. When installing any additional facing material use the Finishing Template (included with the unit) to ensure that the finishing material does not exceed the allowable overlap.

The Finishing Template uses two magnets to attach itself to the flange on the left or right side of the unit (see diagram below). Install the facing material up to the outside edge (when facing the unit) of the finishing template. This template may be discarded after the facing material has been installed.

VENTING

INTRODUCTION

The L676-1 uses the "balanced flue" technology Co Axial system. The inner liner vents products of combustion to the outside while the outer liner draws outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney.

Note: Thesefluepipesmustnotbeconnected to any other appliance.

The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or gas burning appliance. Each direct vent gas appliance must use it's own separate vent system. Common vent systems are prohibited.

12

Regency® L676-1 Direct Vent Gas Fireplace

Image 12
Contents LIBERTY L676-1Gas Fireplace Congratulations MANUFACTURED MOBILE HOME REQUIREMENTSTABLE OF CONTENTS SAFETY LABELINSTALLATION WARRANTYSAFETY LABEL INSTALLATIONREQUIREMENTS INSTALLATIONMA Code - CO Detector 5.08: Modifications to NFPA-54,ChapterUNIT DIMENSIONS INSTALLATIONRegency L676-1Direct Vent Gas Fireplace INSTALLATION GENERAL SAFETY INFORMATIONINSTALLATION CHECKLIST INSTALLATIONINSTALLATION INSTALLATIONDiagram HEAT RELEASE KITINSTALLATION CLEARANCESClearance to Combustibles from Minimum Clearance from Top of Front FacingINSTALLATION INSTALLATIONMANTEL CLEARANCES MANTEL LEG CLEARANCESINSTALLATION INSTALLATIONDiagram Diagram DiagramINSTALLATION UNIT ASSEMBLY PRIOR TO INSTALLATIONINSTALLATION FINISHING TEMPLATEINSTALLATION INSTALLATIONVENT RESTRICTOR POSITION Vent Restrictor PlateINSTALLATION INSTALLATIONEXTERIOR VENT TERMINATION REQUIREMENTS Minimum Clearance RequirementsINSTALLATION INSTALLATIONVENTING ARRANGEMENTS FPI Kit #INSTALLATION INSTALLATIONWhen using Rigid Vent other than RIGID PIPE VENTING SYSTEMSINSTALLATION 5” X 8” RIGID PIPE CROSS REFERENCE CHARTINSTALLATION INSTALLATION INSTALLATIONRegency L676-1Direct Vent Gas Fireplace INSTALLATION INSTALLATIONVENT RESTRICTOR SETTING VENTING ARRANGEMENTSINSTALLATION INSTALLATIONHorizontal Venting with Two 2 90o Elbows Horizontal Venting with Three 3 90o ElbowsINSTALLATION INSTALLATIONVENT RESTRICTOR SETTING Vertical Venting with Three 3 90o ElbowsINSTALLATION INSTALLATIONVENTING ARRANGEMENTS ALLOWABLE VERTICAL TERMINATIONSINSTALLATION UNIT INSTALLATION WITH HORIZONTAL TERMINATIONINSTALLATION DiagramINSTALLATION UNIT INSTALLATION WITH VERTICAL TERMINATIONINSTALLATION DiagramINSTALLATION UNIT INSTALLATIONINSTALLATION ASTROCAP XL DIMENSIONS 946-623/PINSTALLATION PILOT ADJUSTMENTGAS LINE INSTALLATION TESTINGINSTALLATION AERATION ADJUSTMENTWIRING DIAGRAM INSTALLATIONINSTALLATION INSTALLATIONCONVERSION KIT #522-969FROM NG TO LP LP Conversion Kit ContainsINSTALLATION INSTALLATIONNOTE Once the unit has been installed Burner TubeINSTALLATION BRICK PANEL INSTALLATIONINSTALLATION Diagram Right Side Rod with Screen RemovedINSTALLATION INSTALLATIONBurner Orifi ce Cover Plate Diagram DiagramINSTALLATION LOG SET INSTALLATIONINSTALLATION Log kit # 522-930contains the following piecesINSTALLATION INSTALLATION5 Fit log A into the pins on the log tray 7 Fit log E into the pin at the center of log AINSTALLATION INSTALLATIONF BA C 1st Grate PostINSTALLATION INSTALLATIONCompleted Log Set Installation E F A B CINSTALLATION MESH PULL SCREEN INSTALLATIONINSTALLATION Left Side Rod Right Side RodOPTIONAL ANDIRON INSTALLATION INSTALLATIONFinal Installation L900-1 Log GOPERATING INSTRUCTIONS MATCHING REMOTE CONTROL & RECEIVER CODELIGHTING PROCEDURE SHUTDOWN PROCEDUREOPERATING INSTRUCTIONS NORMAL OPERATING SOUNDS OF GAS APPLIANCESCOPY OF LIGHTING PLATE INSTRUCTIONS DO NOT REMOVE THIS INSTRUCTION PLATEMAINTENANCE MAINTENANCE INSTRUCTIONSLOG REPLACEMENT GENERAL VENT MAINTENANCEMAINTENANCE DC SPARK BOX BATTERY REPLACEMENTDC SPARK BOX REPLACEMENT MAINTENANCEMAINTENANCE VALVE TRAY REPLACEMENTMAINTENANCE Latch Location LatchMAINTENANCE MAINTENANCEDC Spark Box DC Spark BoxPARTS LIST MAIN ASSEMBLYPARTS LIST Part #PARTS LIST PARTS LISTPARTS LIST BURNER & LOG ASSEMBLYPARTS LIST Part #WARRANTY The Warranty: Limited LifetimeConditions ExclusionsSee the inside back cover for details