Regency L676-1 Installation, Vent Restrictor Position, Vent Restrictor Plate, Front Cover Plate

Page 13
VENT RESTRICTOR POSITION

INSTALLATION

VENT RESTRICTOR POSITION

Vent restriction is required for certain venting installations, see the diagrams in the "Venting Arrangements" section to determine if they are required for your installation.

The Vent Restrictor plate is located on the inside top of the firebox.

Vent Restrictor Plate

2)Remove the front cover plate by lifting up off of the pins on the left and right side of the firebox.

6)Once the vent restrictor plate is in the required position, secure with screws.

Screws for plugging the holes.

(all holes must be plugged with a screw).

Screw holes for fixing the restrictor plate.

INSTALLATION

To set the vent restriction as indicated in the venting arrangements diagrams, refer to the following instructions;

1)Remove the right side mesh by gathering the mesh together and lifting the curved end of the rod up and out of the bracket located on the top right of the glass frame.

Now slide the straight end of the rod out from the bracket located on the middle inside top of the outer shell. Repeat for left side.

Front Cover Plate

Right Side Pin Shown

3) Remove the glass door.

a. Release the 2 door latches on the left and right side at the top of the firebox.

Latch Location

Latch

7) Vent Restrictor Set 4 = combination of Vent Restrictor Set 1 + installation of the baffle plate (see below).

b. Swing the door out from the top and release the hinge on the left side of the door and lift out.

 

Hinge
Door

4)

Remove the screws that hold the vent

 

restrictor plate in place.

 

5)

Adjust the vent restrictor plate to the required

Right Side Rod with Screen Removed

vent restrictor position as per the diagrams

shown.

 

Relief Doors

Baffle plate

 

Vent Restrictor Set 4

Note: Used only with specific limited horizontal termination. See chart on p. 19 in this manual for details.

Position the baffle plate on the top inside wall of the firebox, push it back until it contacts the back wall of the firebox. Center it between the 2 relief doors (see above diagram), secure with 2 self tapping screws provided.

Regency® L676-1 Direct Vent Gas Fireplace

13

Image 13
Contents LIBERTY L676-1Gas Fireplace MANUFACTURED MOBILE HOME REQUIREMENTS CongratulationsSAFETY LABEL TABLE OF CONTENTSINSTALLATION WARRANTYINSTALLATION SAFETY LABELINSTALLATION REQUIREMENTSMA Code - CO Detector 5.08: Modifications to NFPA-54,ChapterINSTALLATION UNIT DIMENSIONSRegency L676-1Direct Vent Gas Fireplace GENERAL SAFETY INFORMATION INSTALLATIONINSTALLATION CHECKLIST INSTALLATIONINSTALLATION INSTALLATIONDiagram HEAT RELEASE KITCLEARANCES INSTALLATIONClearance to Combustibles from Minimum Clearance from Top of Front FacingINSTALLATION INSTALLATIONMANTEL CLEARANCES MANTEL LEG CLEARANCESINSTALLATION INSTALLATIONDiagram Diagram DiagramUNIT ASSEMBLY PRIOR TO INSTALLATION INSTALLATIONINSTALLATION FINISHING TEMPLATEINSTALLATION INSTALLATIONVENT RESTRICTOR POSITION Vent Restrictor PlateINSTALLATION INSTALLATIONEXTERIOR VENT TERMINATION REQUIREMENTS Minimum Clearance RequirementsINSTALLATION INSTALLATIONVENTING ARRANGEMENTS FPI Kit #INSTALLATION INSTALLATIONWhen using Rigid Vent other than RIGID PIPE VENTING SYSTEMS5” X 8” RIGID PIPE CROSS REFERENCE CHART INSTALLATIONINSTALLATION INSTALLATION INSTALLATIONRegency L676-1Direct Vent Gas Fireplace INSTALLATION INSTALLATIONVENT RESTRICTOR SETTING VENTING ARRANGEMENTSINSTALLATION INSTALLATIONHorizontal Venting with Two 2 90o Elbows Horizontal Venting with Three 3 90o ElbowsINSTALLATION INSTALLATIONVENT RESTRICTOR SETTING Vertical Venting with Three 3 90o ElbowsINSTALLATION INSTALLATIONVENTING ARRANGEMENTS ALLOWABLE VERTICAL TERMINATIONSUNIT INSTALLATION WITH HORIZONTAL TERMINATION INSTALLATIONINSTALLATION DiagramUNIT INSTALLATION WITH VERTICAL TERMINATION INSTALLATIONINSTALLATION DiagramUNIT INSTALLATION INSTALLATIONINSTALLATION ASTROCAP XL DIMENSIONS 946-623/PPILOT ADJUSTMENT INSTALLATIONGAS LINE INSTALLATION TESTINGAERATION ADJUSTMENT INSTALLATIONWIRING DIAGRAM INSTALLATIONINSTALLATION INSTALLATIONCONVERSION KIT #522-969FROM NG TO LP LP Conversion Kit ContainsINSTALLATION INSTALLATIONNOTE Once the unit has been installed Burner TubeBRICK PANEL INSTALLATION INSTALLATIONINSTALLATION Diagram Right Side Rod with Screen RemovedINSTALLATION INSTALLATIONBurner Orifi ce Cover Plate Diagram DiagramLOG SET INSTALLATION INSTALLATIONINSTALLATION Log kit # 522-930contains the following piecesINSTALLATION INSTALLATION5 Fit log A into the pins on the log tray 7 Fit log E into the pin at the center of log AINSTALLATION INSTALLATIONF BA C 1st Grate PostINSTALLATION INSTALLATIONCompleted Log Set Installation E F A B CMESH PULL SCREEN INSTALLATION INSTALLATIONINSTALLATION Left Side Rod Right Side RodINSTALLATION OPTIONAL ANDIRON INSTALLATIONFinal Installation L900-1 Log GMATCHING REMOTE CONTROL & RECEIVER CODE OPERATING INSTRUCTIONSLIGHTING PROCEDURE SHUTDOWN PROCEDURENORMAL OPERATING SOUNDS OF GAS APPLIANCES OPERATING INSTRUCTIONSCOPY OF LIGHTING PLATE INSTRUCTIONS DO NOT REMOVE THIS INSTRUCTION PLATEMAINTENANCE INSTRUCTIONS MAINTENANCELOG REPLACEMENT GENERAL VENT MAINTENANCEDC SPARK BOX BATTERY REPLACEMENT MAINTENANCEDC SPARK BOX REPLACEMENT MAINTENANCEVALVE TRAY REPLACEMENT MAINTENANCEMAINTENANCE Latch Location LatchMAINTENANCE MAINTENANCEDC Spark Box DC Spark BoxMAIN ASSEMBLY PARTS LISTPARTS LIST Part #PARTS LIST PARTS LISTBURNER & LOG ASSEMBLY PARTS LISTPARTS LIST Part #The Warranty: Limited Lifetime WARRANTYConditions ExclusionsSee the inside back cover for details