
MAINTENANCE
11)Disconnect the inlet gas line from the valve.
12)Undo the center wire clip on the side of the firebox.
15) Disconnect the 2 DC Spark generator wires | 17) Remove the 16 screws that hold the valve |
from the DC spark box located in front of | tray to the firebox and slightly pull out the |
the valve. | valve tray. |
13)Unplug the wire harness that connects the modulating coil to the receiver.
14)Unplug the green (TH) and white (TP/TH) wires from the valve.
DC Spark Box
16)Disconnect the spark electrode wire from the DC spark box.
DC Spark Box
Valve Tray
18)Completely pull out the valve tray.
19)Replace the valve tray and reverse steps to
20)Turn on the gas supply and check for gas leaks.
21)
22)
23)
24)
25)
26)
27)
28)
29)
30)Check the inlet and outlet pressures.
31)Check operation of flame control.
32)Check for proper flame appearance.
MAINTENANCE
Regency® | 43 |