Regency L676-1, L676-NG1 Maintenance Instructions, Log Replacement, Glass Gasket, Door Glass

Page 40
MAINTENANCE

MAINTENANCE

MAINTENANCE

INSTRUCTIONS

1)Always turn off the gas valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year. When cleaning the logs, use a soft clean paint brush as the logs are fragile and easily damaged.

2)Clean appliance and door with a damp cloth (never when unit is hot). Never use an abrasive cleaner. The glass should be cleaned with a gas fireplace glass cleaner.

The glass should be cleaned when it starts looking cloudy.

3)The heater is finished in a heat resistant paint and should only be refinished with heat resistant paint. Regency® uses StoveBright Paint - Metallic Black #6309.

4)Make a periodic check of burner for proper position and condition. Visually check the flame of the burner periodically, making sure the flames are steady; not lifting or floating. If there is a problem, call a qualified service person.

5)The appliance and venting system must be inspected before use, and at least annually, by a qualified field service person, to ensure that the flow of combustion and ventilation air is not obstructed.

Note: Never operate the appliance without the glass properly secured in place.

6) Do not use this appliance if any part has been

under water. Immediately call a qualified

These components should be replaced immediately.

2)Remove the Cap, and shine a flashlight down the Vent. Remove any bird nests, or other foreign material.

3)Check for evidences of excessive condensation,suchaswaterdropletsforming in the inner liner, and subsequently dripping out the joints, Continuous condensation can cause corrosion of caps, pipe, and fittings. It may be caused by having excessive lateral runs, too many elbows, and exterior portions of the system being exposed to cold weather.

4)Inspect joints, to verify that no pipe sections or fittings have been disturbed, and consequently loosened. Also check mechanical supports such as Wall Straps, or plumbers' tape for rigidity.

LOG REPLACEMENT

The unit should never be used with broken logs. Turn off the gas valve and allow the unit to cool before opening door and carefully remove the logs. (The pilot light generates enough heat to burn someone.) If for any reason a log should need replacement, you must use the proper replacement log. The position of these logs must be as shown in the diagrams under Log Installation.

Note: Improper positioning of logs may create carbon build-up and will severely alter the unit's performance which is not covered under warranty.

GLASS GASKET

If the glass gasket requires replacement use a tadpole glass gasket (Part # 936-155).

DOOR GLASS

Your Regency® fireplace is supplied with high temperature 5mm-Ceramic glass. If your glass requires cleaning, we recommend using an approved glass cleaner available at all authorized dealers. Do not use abrasive materials.

CAUTION & WARNINGS:

*Do not clean when the glass is hot.

*The use of substitute glass will void all product warranties.

*Care must be taken to avoid breakage of the glass.

*Do not strike or abuse the glass.

*Do not operate this fireplace without the glass front or with a cracked or broken glass front.

*Wear gloves when removing damaged or broken glass.

*Replacement of the glass panel(s) should be done by a licensed or qualified service per son.

GLASS REPLACEMENT

In the event that you break your glass by impact, purchase your replacement from an authorized Regency® dealer only.

Replacement glass is shipped already installed into the door frame.

MAINTENANCE

service technician to inspect the appliance

and to replace any part of the control system

and any gas control which has been under

water.

7) In the event this appliance has been

serviced check that the vent-air system

has been properly resealed & reinstalled

in accordance with the manufacturer's

instructions.

8) Verify operation after servicing.

GENERAL VENT

MAINTENANCE

Conduct an inspection of the venting system semi-annually. Recommended areas to inspect as follows:

1)Check the Venting System for corrosion in areas that are exposed to the elements. These will appear as rust spots or streaks, and in extreme cases, holes.

THERMOPILE /

THERMOCOUPLE

1)Remove the valve tray by following the procedures from "Valve Tray Replacement" section.

2)Disconnect thermocouple by loosening nut from the valve with a 9mm wrench. Disconnect thermopile by loosening 2 screws marked TP on the valve.

3)Remove 2 screws from the pilot assembly and pull up far enough to be able to loosen the thermocouple or thermopile with a 7/16" wrench. NOTE: the pilot line is very fragile, use caution when pulling it up.

4)Drop the thermocouple or thermopile down through the extrusion and pull it out of the unit.

5)Reinstall the new ones in reverse order.

CAUTION: Wear gloves when removing damaged or broken glass.

WARNING: Do not operate the appliance with the glass panels removed, cracked or broken. Replacement of the glass panels should be done by a licensed or qualified service person.

40

Regency® L676-1 Direct Vent Gas Fireplace

Image 40
Contents LIBERTY L676-1Gas Fireplace Congratulations MANUFACTURED MOBILE HOME REQUIREMENTSTABLE OF CONTENTS SAFETY LABELINSTALLATION WARRANTYSAFETY LABEL INSTALLATIONREQUIREMENTS INSTALLATIONMA Code - CO Detector 5.08: Modifications to NFPA-54,ChapterINSTALLATION UNIT DIMENSIONSRegency L676-1Direct Vent Gas Fireplace INSTALLATION GENERAL SAFETY INFORMATIONINSTALLATION CHECKLIST INSTALLATIONINSTALLATION INSTALLATIONDiagram HEAT RELEASE KITINSTALLATION CLEARANCESClearance to Combustibles from Minimum Clearance from Top of Front FacingINSTALLATION INSTALLATIONMANTEL CLEARANCES MANTEL LEG CLEARANCESINSTALLATION INSTALLATIONDiagram Diagram DiagramINSTALLATION UNIT ASSEMBLY PRIOR TO INSTALLATIONINSTALLATION FINISHING TEMPLATEINSTALLATION INSTALLATIONVENT RESTRICTOR POSITION Vent Restrictor PlateINSTALLATION INSTALLATIONEXTERIOR VENT TERMINATION REQUIREMENTS Minimum Clearance RequirementsINSTALLATION INSTALLATIONVENTING ARRANGEMENTS FPI Kit #INSTALLATION INSTALLATIONWhen using Rigid Vent other than RIGID PIPE VENTING SYSTEMS5” X 8” RIGID PIPE CROSS REFERENCE CHART INSTALLATIONINSTALLATION INSTALLATION INSTALLATIONRegency L676-1Direct Vent Gas Fireplace INSTALLATION INSTALLATIONVENT RESTRICTOR SETTING VENTING ARRANGEMENTSINSTALLATION INSTALLATIONHorizontal Venting with Two 2 90o Elbows Horizontal Venting with Three 3 90o ElbowsINSTALLATION INSTALLATIONVENT RESTRICTOR SETTING Vertical Venting with Three 3 90o ElbowsINSTALLATION INSTALLATIONVENTING ARRANGEMENTS ALLOWABLE VERTICAL TERMINATIONSINSTALLATION UNIT INSTALLATION WITH HORIZONTAL TERMINATIONINSTALLATION DiagramINSTALLATION UNIT INSTALLATION WITH VERTICAL TERMINATIONINSTALLATION DiagramINSTALLATION UNIT INSTALLATIONINSTALLATION ASTROCAP XL DIMENSIONS 946-623/PINSTALLATION PILOT ADJUSTMENTGAS LINE INSTALLATION TESTINGINSTALLATION AERATION ADJUSTMENTWIRING DIAGRAM INSTALLATIONINSTALLATION INSTALLATIONCONVERSION KIT #522-969FROM NG TO LP LP Conversion Kit ContainsINSTALLATION INSTALLATIONNOTE Once the unit has been installed Burner TubeINSTALLATION BRICK PANEL INSTALLATIONINSTALLATION Diagram Right Side Rod with Screen RemovedINSTALLATION INSTALLATIONBurner Orifi ce Cover Plate Diagram DiagramINSTALLATION LOG SET INSTALLATIONINSTALLATION Log kit # 522-930contains the following piecesINSTALLATION INSTALLATION5 Fit log A into the pins on the log tray 7 Fit log E into the pin at the center of log AINSTALLATION INSTALLATIONF BA C 1st Grate PostINSTALLATION INSTALLATIONCompleted Log Set Installation E F A B CINSTALLATION MESH PULL SCREEN INSTALLATIONINSTALLATION Left Side Rod Right Side RodOPTIONAL ANDIRON INSTALLATION INSTALLATIONFinal Installation L900-1 Log GOPERATING INSTRUCTIONS MATCHING REMOTE CONTROL & RECEIVER CODELIGHTING PROCEDURE SHUTDOWN PROCEDUREOPERATING INSTRUCTIONS NORMAL OPERATING SOUNDS OF GAS APPLIANCESCOPY OF LIGHTING PLATE INSTRUCTIONS DO NOT REMOVE THIS INSTRUCTION PLATEMAINTENANCE MAINTENANCE INSTRUCTIONSLOG REPLACEMENT GENERAL VENT MAINTENANCEMAINTENANCE DC SPARK BOX BATTERY REPLACEMENTDC SPARK BOX REPLACEMENT MAINTENANCEMAINTENANCE VALVE TRAY REPLACEMENTMAINTENANCE Latch Location LatchMAINTENANCE MAINTENANCEDC Spark Box DC Spark BoxPARTS LIST MAIN ASSEMBLYPARTS LIST Part #PARTS LIST PARTS LISTPARTS LIST BURNER & LOG ASSEMBLYPARTS LIST Part #WARRANTY The Warranty: Limited LifetimeConditions ExclusionsSee the inside back cover for details