Regency L676-1 Installation, Important Message Save These Instructions, Before You Start

Page 7
INSTALLATION

INSTALLATION

IMPORTANT MESSAGE

SAVE THESE

INSTRUCTIONS

The L676-1 Direct Vent Fireplace must be installed in accordance with these instructions. Carefully read all the instructions in this manual first. Consult the "authority having jurisdiction" to determine the need for a permit prior to starting the installation. It is the responsibility of the installer to ensure this fireplace is installed in compliance with manufacturers instructions and all applicable codes.

BEFORE YOU START

Safe installation and operation of this appliance requires common sense, however, we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following:

INSTALLATION AND REPAIR SHOULD BE DONE BY AN AUTHORIZED SERVICE PERSON. THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A PROFESSIONAL SERVICE PERSON. MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, BEDDING MATERIAL, ETC. IT IS IMPERATIVE THAT CONTROL COMPARTMENTS, BURNERS AND CIRCULATING AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN.

DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.

WARNING: FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AND MAY CAUSE A SERIOUS HOUSE FIRE.

CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES, ESPE- CIALLY THE FIREPLACE GLASS, AND SHOULD STAYAWAYTOAVOID BURNS OR CLOTHING IGNITION.

YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.

CLOTHING OR OTHER FLAMMABLE MATERIALSHOULDNOTBEPLACED ON OR NEAR THE APPLIANCE.

GENERAL SAFETY

INFORMATION

1)The appliance installation must conform with local codes or, in the absence of local codes, with the current Canadian or National Gas Codes, CAN1-B149 or ANSI Z223.1 Installation Codes.

2)The appliance when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes with the current National Electrical Code, ANSI/NFPA 70 or CSA C22.1 Canadian Electrical Code.

3)See general construction and assembly instructions. The appliance and vent should be enclosed.

4)This appliance must be connected to the specified vent and termination cap to the outside of the building envelope. Never vent to another room or inside a building. Make sure that the vent is fitted as per Venting instructions.

5)Inspect the venting system annually for blockage and any signs of deterioration.

6)Venting terminals shall not be recessed into a wall or siding.

7)Any safety glass removed for servicing must be replaced prior to operating the appliance.

8)To prevent injury, do not allow anyone who is unfamiliar with the operation to use the fireplace.

9)Wearglovesandsafety glassesforprotection while doing required maintenance.

10)Be aware of electrical wiring locations in walls and ceilings when cutting holes for termination.

11)Under no circumstances should this appliance be modified. Parts that have to be removed for servicing should be replaced prior to operating this appliance.

12)Installation and any repairs to this appliance should be done by an authorized service person.Aprofessional service person should be called to inspect this appliance annually. Make it a practice to have all of your gas appliances checked annually.

13)Do not slam shut or strike the glass door.

14)Under no circumstances should any solid fuels (wood, paper, cardboard, coal, etc.) be used in this appliance.

15)The appliance area must be kept clear and free of combustible materials, (gases and other flammable vapours and liquids).

Emissions from burning wood or gas could

contain chemicals known to the State of

California to cause cancer, birth defects or

other reproductive harm.

INSTALLATION

CHECKLIST

1)Locate appliance

a)Room location (Refer to "Locating Your Gas fireplace" section)

b)Clearances to Combustibles (Refer to "Clearances" section)

c)Mantle Clearances (Refer to "Mantel Clearances" section)

d)Framing & Finishing Requirements (Refer to "Framing & Finishing" section)

e)Venting Requirements (Refer to "Venting" section)

2)Assemble Top and Side Standoffs (Refer to "Unit Assembly Prior to Installation).

3)Install batteries; four "AA" batteries in the wall mounted receiver; three "AAA" batteries in the remote control and one "AA" battery into the DC Sparker. (Refer to remote control manual for operating instructions).

4)Convert to propane if desired (Refer to "Conversion from NG to LP" section).

5)Slide unit into place.

6)Install vent (Refer to "Venting Arrangement" sections).

7)Make gas connections (Refer to "Gas Line Installation section).

8)Test the pilot (Refer to "Pilot Adjustment" section).

INSTALLATION

Regency® L676-1 Direct Vent Gas Fireplace

7

Image 7
Contents LIBERTY L676-1Gas Fireplace MANUFACTURED MOBILE HOME REQUIREMENTS CongratulationsWARRANTY TABLE OF CONTENTSSAFETY LABEL INSTALLATIONINSTALLATION SAFETY LABEL5.08: Modifications to NFPA-54,Chapter REQUIREMENTSINSTALLATION MA Code - CO DetectorINSTALLATION UNIT DIMENSIONSRegency L676-1Direct Vent Gas Fireplace INSTALLATION INSTALLATIONGENERAL SAFETY INFORMATION INSTALLATION CHECKLISTHEAT RELEASE KIT INSTALLATIONINSTALLATION DiagramMinimum Clearance from Top of Front Facing INSTALLATIONCLEARANCES Clearance to Combustibles fromMANTEL LEG CLEARANCES INSTALLATIONINSTALLATION MANTEL CLEARANCESDiagram INSTALLATIONINSTALLATION Diagram DiagramFINISHING TEMPLATE INSTALLATIONUNIT ASSEMBLY PRIOR TO INSTALLATION INSTALLATIONVent Restrictor Plate INSTALLATIONINSTALLATION VENT RESTRICTOR POSITIONMinimum Clearance Requirements INSTALLATIONINSTALLATION EXTERIOR VENT TERMINATION REQUIREMENTSFPI Kit # INSTALLATIONINSTALLATION VENTING ARRANGEMENTSRIGID PIPE VENTING SYSTEMS INSTALLATIONINSTALLATION When using Rigid Vent other than5” X 8” RIGID PIPE CROSS REFERENCE CHART INSTALLATIONINSTALLATION INSTALLATION INSTALLATIONRegency L676-1Direct Vent Gas Fireplace VENTING ARRANGEMENTS INSTALLATIONINSTALLATION VENT RESTRICTOR SETTINGHorizontal Venting with Three 3 90o Elbows INSTALLATIONINSTALLATION Horizontal Venting with Two 2 90o ElbowsVertical Venting with Three 3 90o Elbows INSTALLATIONINSTALLATION VENT RESTRICTOR SETTINGALLOWABLE VERTICAL TERMINATIONS INSTALLATIONINSTALLATION VENTING ARRANGEMENTSDiagram INSTALLATIONUNIT INSTALLATION WITH HORIZONTAL TERMINATION INSTALLATIONDiagram INSTALLATIONUNIT INSTALLATION WITH VERTICAL TERMINATION INSTALLATIONASTROCAP XL DIMENSIONS 946-623/P INSTALLATIONUNIT INSTALLATION INSTALLATIONTESTING INSTALLATIONPILOT ADJUSTMENT GAS LINE INSTALLATIONINSTALLATION INSTALLATIONAERATION ADJUSTMENT WIRING DIAGRAMLP Conversion Kit Contains INSTALLATIONINSTALLATION CONVERSION KIT #522-969FROM NG TO LPBurner Tube INSTALLATIONINSTALLATION NOTE Once the unit has been installedDiagram Right Side Rod with Screen Removed INSTALLATIONBRICK PANEL INSTALLATION INSTALLATIONDiagram INSTALLATIONINSTALLATION Burner Orifi ce Cover Plate DiagramLog kit # 522-930contains the following pieces INSTALLATIONLOG SET INSTALLATION INSTALLATION7 Fit log E into the pin at the center of log A INSTALLATIONINSTALLATION 5 Fit log A into the pins on the log tray1st Grate Post INSTALLATIONINSTALLATION F BA CE F A B C INSTALLATIONINSTALLATION Completed Log Set InstallationLeft Side Rod Right Side Rod INSTALLATIONMESH PULL SCREEN INSTALLATION INSTALLATIONLog G OPTIONAL ANDIRON INSTALLATIONINSTALLATION Final Installation L900-1SHUTDOWN PROCEDURE OPERATING INSTRUCTIONSMATCHING REMOTE CONTROL & RECEIVER CODE LIGHTING PROCEDUREDO NOT REMOVE THIS INSTRUCTION PLATE OPERATING INSTRUCTIONSNORMAL OPERATING SOUNDS OF GAS APPLIANCES COPY OF LIGHTING PLATE INSTRUCTIONSGENERAL VENT MAINTENANCE MAINTENANCEMAINTENANCE INSTRUCTIONS LOG REPLACEMENTMAINTENANCE MAINTENANCEDC SPARK BOX BATTERY REPLACEMENT DC SPARK BOX REPLACEMENTLatch Location Latch MAINTENANCEVALVE TRAY REPLACEMENT MAINTENANCEDC Spark Box MAINTENANCEMAINTENANCE DC Spark BoxPart # PARTS LISTMAIN ASSEMBLY PARTS LISTPARTS LIST PARTS LISTPart # PARTS LISTBURNER & LOG ASSEMBLY PARTS LISTExclusions WARRANTYThe Warranty: Limited Lifetime ConditionsSee the inside back cover for details