Regency L676-LP1, L676-NG1 Installation, Horizontal Venting with Two 2 90o Elbows, Option, H + H1

Page 20
Horizontal Venting with Two (2) 90o Elbows

INSTALLATION

Horizontal Venting with Two (2) 90o Elbows

INSTALLATION

One 90o elbow = Two 45o elbows.

Option

 

V

H + H1

With these

options,

A)

2'

Min.

4' Max.

maximum total pipe length

B)

3'

Min.

6' Max.

is 30 feet with minimum

C)

4'

Min.

8' Max.

of 6 feet total vertical and

 

 

 

 

maximum 10

feet total

D)

5'

Min.

9' Max.

 

 

 

 

horizontal.

 

E)

6' Min.

10' Max.

 

 

 

Please note minimum 1 foot between 90o elbows is required.

VENT RESTRICTOR SETTING:

Vent restrictor factory set at Set 1, no adjustment required.

Horizontal Venting with Three (3) 90o Elbows

One 90o elbow = Two 45o elbows.

Option V

H

V + V1 H + H1

A)2' Min. 1' Max. 3' Min. 2' Max.

B)2' Min. 2' Max. 5' Min. 4' Max.

C)3' Min. 2' Max. 7' Min. 5' Max.

D)4' Min. 3 Max. 9' Min. 6' Max.

E)5' Min. 4' Max. 10' Min. 7' Max.

F)6' Min. 6' Max. 11' Min. 9' Max.

With these options, max. total pipe length is 30 feet with min. of 11 feet total vertical and max. 9 feet total horizontal.

Please note min. 1 foot between 90o elbows is required.

VENT RESTRICTOR SETTING:

Vent restrictor factory set at Set 1, no adjustment required.

20

Regency® L676-1 Direct Vent Gas Fireplace

Image 20
Contents LIBERTY L676-1Gas Fireplace Congratulations MANUFACTURED MOBILE HOME REQUIREMENTSTABLE OF CONTENTS SAFETY LABELINSTALLATION WARRANTYSAFETY LABEL INSTALLATIONREQUIREMENTS INSTALLATIONMA Code - CO Detector 5.08: Modifications to NFPA-54,ChapterRegency L676-1Direct Vent Gas Fireplace UNIT DIMENSIONSINSTALLATION INSTALLATION GENERAL SAFETY INFORMATIONINSTALLATION CHECKLIST INSTALLATIONINSTALLATION INSTALLATIONDiagram HEAT RELEASE KITINSTALLATION CLEARANCESClearance to Combustibles from Minimum Clearance from Top of Front FacingINSTALLATION INSTALLATIONMANTEL CLEARANCES MANTEL LEG CLEARANCESINSTALLATION INSTALLATIONDiagram Diagram DiagramINSTALLATION UNIT ASSEMBLY PRIOR TO INSTALLATIONINSTALLATION FINISHING TEMPLATEINSTALLATION INSTALLATIONVENT RESTRICTOR POSITION Vent Restrictor PlateINSTALLATION INSTALLATIONEXTERIOR VENT TERMINATION REQUIREMENTS Minimum Clearance RequirementsINSTALLATION INSTALLATIONVENTING ARRANGEMENTS FPI Kit #INSTALLATION INSTALLATIONWhen using Rigid Vent other than RIGID PIPE VENTING SYSTEMSINSTALLATION INSTALLATION5” X 8” RIGID PIPE CROSS REFERENCE CHART Regency L676-1Direct Vent Gas Fireplace INSTALLATIONINSTALLATION INSTALLATION INSTALLATIONVENT RESTRICTOR SETTING VENTING ARRANGEMENTSINSTALLATION INSTALLATIONHorizontal Venting with Two 2 90o Elbows Horizontal Venting with Three 3 90o ElbowsINSTALLATION INSTALLATIONVENT RESTRICTOR SETTING Vertical Venting with Three 3 90o ElbowsINSTALLATION INSTALLATIONVENTING ARRANGEMENTS ALLOWABLE VERTICAL TERMINATIONSINSTALLATION UNIT INSTALLATION WITH HORIZONTAL TERMINATIONINSTALLATION DiagramINSTALLATION UNIT INSTALLATION WITH VERTICAL TERMINATIONINSTALLATION DiagramINSTALLATION UNIT INSTALLATIONINSTALLATION ASTROCAP XL DIMENSIONS 946-623/PINSTALLATION PILOT ADJUSTMENTGAS LINE INSTALLATION TESTINGINSTALLATION AERATION ADJUSTMENTWIRING DIAGRAM INSTALLATIONINSTALLATION INSTALLATIONCONVERSION KIT #522-969FROM NG TO LP LP Conversion Kit ContainsINSTALLATION INSTALLATIONNOTE Once the unit has been installed Burner TubeINSTALLATION BRICK PANEL INSTALLATIONINSTALLATION Diagram Right Side Rod with Screen RemovedINSTALLATION INSTALLATIONBurner Orifi ce Cover Plate Diagram DiagramINSTALLATION LOG SET INSTALLATIONINSTALLATION Log kit # 522-930contains the following piecesINSTALLATION INSTALLATION5 Fit log A into the pins on the log tray 7 Fit log E into the pin at the center of log AINSTALLATION INSTALLATIONF BA C 1st Grate PostINSTALLATION INSTALLATIONCompleted Log Set Installation E F A B CINSTALLATION MESH PULL SCREEN INSTALLATIONINSTALLATION Left Side Rod Right Side RodOPTIONAL ANDIRON INSTALLATION INSTALLATIONFinal Installation L900-1 Log GOPERATING INSTRUCTIONS MATCHING REMOTE CONTROL & RECEIVER CODELIGHTING PROCEDURE SHUTDOWN PROCEDUREOPERATING INSTRUCTIONS NORMAL OPERATING SOUNDS OF GAS APPLIANCESCOPY OF LIGHTING PLATE INSTRUCTIONS DO NOT REMOVE THIS INSTRUCTION PLATEMAINTENANCE MAINTENANCE INSTRUCTIONSLOG REPLACEMENT GENERAL VENT MAINTENANCEMAINTENANCE DC SPARK BOX BATTERY REPLACEMENTDC SPARK BOX REPLACEMENT MAINTENANCEMAINTENANCE VALVE TRAY REPLACEMENTMAINTENANCE Latch Location LatchMAINTENANCE MAINTENANCEDC Spark Box DC Spark BoxPARTS LIST MAIN ASSEMBLYPARTS LIST Part #PARTS LIST PARTS LISTPARTS LIST BURNER & LOG ASSEMBLYPARTS LIST Part #WARRANTY The Warranty: Limited LifetimeConditions ExclusionsSee the inside back cover for details