Regency L676-LP1, L676-NG1, L676-1 Requirements, MA Code - CO Detector, Installation, Obstructions

Page 5
REQUIREMENTS

REQUIREMENTS

MA Code - CO Detector

(for the State of Massachusetts only)

5.08: Modifications to NFPA-54, Chapter 10

(2) Revise 10.8.3 by adding the following additional requirements:

(a)For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:

1.INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors

a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.

b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.

2.APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.

3.SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight

(8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, "GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL

OBSTRUCTIONS".

4.INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4.

(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:

1.The equipment listed in Chapter 10 entitled "Equipment Not Required To Be Vented" in the most current edition of NFPA 54 as adopted by the Board; and

2.Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes.

(c)MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:

1.Detailed instructions for the installation of the venting system design or the venting system components; and

2.A complete parts list for the venting system design or venting system.

(d)MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies "special venting systems", the following requirements shall be satisfied by the manufacturer:

1.The referenced "special venting system" instructions shall be included with the appliance or equipment installation instructions; and

2.The "special venting systems" shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions.

(e)A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.

Regency® L676-1 Direct Vent Gas Fireplace

5

INSTALLATION

Image 5
Contents LIBERTY L676-1Gas Fireplace MANUFACTURED MOBILE HOME REQUIREMENTS CongratulationsSAFETY LABEL TABLE OF CONTENTSINSTALLATION WARRANTYINSTALLATION SAFETY LABELINSTALLATION REQUIREMENTSMA Code - CO Detector 5.08: Modifications to NFPA-54,ChapterRegency L676-1Direct Vent Gas Fireplace UNIT DIMENSIONSINSTALLATION GENERAL SAFETY INFORMATION INSTALLATIONINSTALLATION CHECKLIST INSTALLATIONINSTALLATION INSTALLATIONDiagram HEAT RELEASE KITCLEARANCES INSTALLATIONClearance to Combustibles from Minimum Clearance from Top of Front FacingINSTALLATION INSTALLATIONMANTEL CLEARANCES MANTEL LEG CLEARANCESINSTALLATION INSTALLATIONDiagram Diagram DiagramUNIT ASSEMBLY PRIOR TO INSTALLATION INSTALLATIONINSTALLATION FINISHING TEMPLATEINSTALLATION INSTALLATIONVENT RESTRICTOR POSITION Vent Restrictor PlateINSTALLATION INSTALLATIONEXTERIOR VENT TERMINATION REQUIREMENTS Minimum Clearance RequirementsINSTALLATION INSTALLATIONVENTING ARRANGEMENTS FPI Kit #INSTALLATION INSTALLATIONWhen using Rigid Vent other than RIGID PIPE VENTING SYSTEMSINSTALLATION INSTALLATION5” X 8” RIGID PIPE CROSS REFERENCE CHART Regency L676-1Direct Vent Gas Fireplace INSTALLATIONINSTALLATION INSTALLATION INSTALLATIONVENT RESTRICTOR SETTING VENTING ARRANGEMENTSINSTALLATION INSTALLATIONHorizontal Venting with Two 2 90o Elbows Horizontal Venting with Three 3 90o ElbowsINSTALLATION INSTALLATIONVENT RESTRICTOR SETTING Vertical Venting with Three 3 90o ElbowsINSTALLATION INSTALLATIONVENTING ARRANGEMENTS ALLOWABLE VERTICAL TERMINATIONSUNIT INSTALLATION WITH HORIZONTAL TERMINATION INSTALLATIONINSTALLATION DiagramUNIT INSTALLATION WITH VERTICAL TERMINATION INSTALLATIONINSTALLATION DiagramUNIT INSTALLATION INSTALLATIONINSTALLATION ASTROCAP XL DIMENSIONS 946-623/PPILOT ADJUSTMENT INSTALLATIONGAS LINE INSTALLATION TESTINGAERATION ADJUSTMENT INSTALLATIONWIRING DIAGRAM INSTALLATIONINSTALLATION INSTALLATIONCONVERSION KIT #522-969FROM NG TO LP LP Conversion Kit ContainsINSTALLATION INSTALLATIONNOTE Once the unit has been installed Burner TubeBRICK PANEL INSTALLATION INSTALLATIONINSTALLATION Diagram Right Side Rod with Screen RemovedINSTALLATION INSTALLATIONBurner Orifi ce Cover Plate Diagram DiagramLOG SET INSTALLATION INSTALLATIONINSTALLATION Log kit # 522-930contains the following piecesINSTALLATION INSTALLATION5 Fit log A into the pins on the log tray 7 Fit log E into the pin at the center of log AINSTALLATION INSTALLATIONF BA C 1st Grate PostINSTALLATION INSTALLATIONCompleted Log Set Installation E F A B CMESH PULL SCREEN INSTALLATION INSTALLATIONINSTALLATION Left Side Rod Right Side RodINSTALLATION OPTIONAL ANDIRON INSTALLATIONFinal Installation L900-1 Log GMATCHING REMOTE CONTROL & RECEIVER CODE OPERATING INSTRUCTIONSLIGHTING PROCEDURE SHUTDOWN PROCEDURENORMAL OPERATING SOUNDS OF GAS APPLIANCES OPERATING INSTRUCTIONSCOPY OF LIGHTING PLATE INSTRUCTIONS DO NOT REMOVE THIS INSTRUCTION PLATEMAINTENANCE INSTRUCTIONS MAINTENANCELOG REPLACEMENT GENERAL VENT MAINTENANCEDC SPARK BOX BATTERY REPLACEMENT MAINTENANCEDC SPARK BOX REPLACEMENT MAINTENANCEVALVE TRAY REPLACEMENT MAINTENANCEMAINTENANCE Latch Location LatchMAINTENANCE MAINTENANCEDC Spark Box DC Spark BoxMAIN ASSEMBLY PARTS LISTPARTS LIST Part #PARTS LIST PARTS LISTBURNER & LOG ASSEMBLY PARTS LISTPARTS LIST Part #The Warranty: Limited Lifetime WARRANTYConditions ExclusionsSee the inside back cover for details