INSTALLATION
CONVERSION KIT #522-969 FROM NG TO LP
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER, IF IN DOUBT DO NOT DO THIS CONVERSION!!
INSTALLATION
LP Conversion Kit Contains:
Qty. | Part # | Description |
1 | LP Conversion Coil | |
1 | LP Pilot Orifi ce | |
1 | Orifi ce #51 | |
1 | Allen Key | |
1 | LP Conversion Decal | |
1 | Red Propane Label |
1
1)Remove the right side mesh by gathering the mesh together and lifting the curved end of the rod up and out of the bracket located on the top right of the glass frame.
Now slide the straight end of the rod out from the bracket located on the middle inside top of the outer shell. Repeat for left side.
2)Remove the front cover plate by lifting up off of the pins on the left and right side of the fi rebox.
Front Cover Plate | Right Side Pin Shown |
3)Remove the glass door.
a.Release the 2 door latches on the left and right side at the top of the fi rebox.
b.Swing the door out from the top and release the hinge on the left side of the door and lift out.
HingeDoor
c.Place the door on a soft surface to prevent scratching.
4)Remove the burner orifi ce cover plate from the log tray by undoing the 2 screws.
Burner Orifi ce Cover Plate
Latch Location
Latch
5) Remove the grate by undoing the 3 screws.
Right Side Rod with Screen Removed
Grate
28 | Regency® |