Regency L676-1 Installation, CONVERSION KIT #522-969FROM NG TO LP, LP Conversion Kit Contains

Page 28
CONVERSION KIT #522-969 FROM NG TO LP

INSTALLATION

CONVERSION KIT #522-969 FROM NG TO LP

THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER, IF IN DOUBT DO NOT DO THIS CONVERSION!!

INSTALLATION

LP Conversion Kit Contains:

Qty.

Part #
Description

1

910-582

LP Conversion Coil

1

910-037

LP Pilot Orifi ce

1

904-645

Orifi ce #51

1

904-529

Allen Key

1

918-590

LP Conversion Decal

1

908-528

Red Propane Label

1918-742 Instruction Sheet

1)Remove the right side mesh by gathering the mesh together and lifting the curved end of the rod up and out of the bracket located on the top right of the glass frame.

Now slide the straight end of the rod out from the bracket located on the middle inside top of the outer shell. Repeat for left side.

2)Remove the front cover plate by lifting up off of the pins on the left and right side of the fi rebox.

Front Cover Plate

Right Side Pin Shown

3)Remove the glass door.

a.Release the 2 door latches on the left and right side at the top of the fi rebox.

b.Swing the door out from the top and release the hinge on the left side of the door and lift out.

HingeDoor

c.Place the door on a soft surface to prevent scratching.

4)Remove the burner orifi ce cover plate from the log tray by undoing the 2 screws.

Burner Orifi ce Cover Plate

Latch Location

Latch

5) Remove the grate by undoing the 3 screws.

Right Side Rod with Screen Removed

Grate

28

Regency® L676-1 Direct Vent Gas Fireplace

Image 28
Contents LIBERTY L676-1Gas Fireplace Congratulations MANUFACTURED MOBILE HOME REQUIREMENTSTABLE OF CONTENTS SAFETY LABELINSTALLATION WARRANTYSAFETY LABEL INSTALLATIONREQUIREMENTS INSTALLATIONMA Code - CO Detector 5.08: Modifications to NFPA-54,ChapterINSTALLATION UNIT DIMENSIONSRegency L676-1Direct Vent Gas Fireplace INSTALLATION GENERAL SAFETY INFORMATIONINSTALLATION CHECKLIST INSTALLATIONINSTALLATION INSTALLATIONDiagram HEAT RELEASE KITINSTALLATION CLEARANCESClearance to Combustibles from Minimum Clearance from Top of Front FacingINSTALLATION INSTALLATIONMANTEL CLEARANCES MANTEL LEG CLEARANCESINSTALLATION INSTALLATIONDiagram Diagram DiagramINSTALLATION UNIT ASSEMBLY PRIOR TO INSTALLATIONINSTALLATION FINISHING TEMPLATEINSTALLATION INSTALLATIONVENT RESTRICTOR POSITION Vent Restrictor PlateINSTALLATION INSTALLATIONEXTERIOR VENT TERMINATION REQUIREMENTS Minimum Clearance RequirementsINSTALLATION INSTALLATIONVENTING ARRANGEMENTS FPI Kit #INSTALLATION INSTALLATIONWhen using Rigid Vent other than RIGID PIPE VENTING SYSTEMS5” X 8” RIGID PIPE CROSS REFERENCE CHART INSTALLATIONINSTALLATION INSTALLATION INSTALLATIONRegency L676-1Direct Vent Gas Fireplace INSTALLATION INSTALLATIONVENT RESTRICTOR SETTING VENTING ARRANGEMENTSINSTALLATION INSTALLATIONHorizontal Venting with Two 2 90o Elbows Horizontal Venting with Three 3 90o ElbowsINSTALLATION INSTALLATIONVENT RESTRICTOR SETTING Vertical Venting with Three 3 90o ElbowsINSTALLATION INSTALLATIONVENTING ARRANGEMENTS ALLOWABLE VERTICAL TERMINATIONSINSTALLATION UNIT INSTALLATION WITH HORIZONTAL TERMINATIONINSTALLATION DiagramINSTALLATION UNIT INSTALLATION WITH VERTICAL TERMINATIONINSTALLATION DiagramINSTALLATION UNIT INSTALLATIONINSTALLATION ASTROCAP XL DIMENSIONS 946-623/PINSTALLATION PILOT ADJUSTMENTGAS LINE INSTALLATION TESTINGINSTALLATION AERATION ADJUSTMENTWIRING DIAGRAM INSTALLATIONINSTALLATION INSTALLATIONCONVERSION KIT #522-969FROM NG TO LP LP Conversion Kit ContainsINSTALLATION INSTALLATIONNOTE Once the unit has been installed Burner TubeINSTALLATION BRICK PANEL INSTALLATIONINSTALLATION Diagram Right Side Rod with Screen RemovedINSTALLATION INSTALLATIONBurner Orifi ce Cover Plate Diagram DiagramINSTALLATION LOG SET INSTALLATIONINSTALLATION Log kit # 522-930contains the following piecesINSTALLATION INSTALLATION5 Fit log A into the pins on the log tray 7 Fit log E into the pin at the center of log AINSTALLATION INSTALLATIONF BA C 1st Grate PostINSTALLATION INSTALLATIONCompleted Log Set Installation E F A B CINSTALLATION MESH PULL SCREEN INSTALLATIONINSTALLATION Left Side Rod Right Side RodOPTIONAL ANDIRON INSTALLATION INSTALLATIONFinal Installation L900-1 Log GOPERATING INSTRUCTIONS MATCHING REMOTE CONTROL & RECEIVER CODELIGHTING PROCEDURE SHUTDOWN PROCEDUREOPERATING INSTRUCTIONS NORMAL OPERATING SOUNDS OF GAS APPLIANCESCOPY OF LIGHTING PLATE INSTRUCTIONS DO NOT REMOVE THIS INSTRUCTION PLATEMAINTENANCE MAINTENANCE INSTRUCTIONSLOG REPLACEMENT GENERAL VENT MAINTENANCEMAINTENANCE DC SPARK BOX BATTERY REPLACEMENTDC SPARK BOX REPLACEMENT MAINTENANCEMAINTENANCE VALVE TRAY REPLACEMENTMAINTENANCE Latch Location LatchMAINTENANCE MAINTENANCEDC Spark Box DC Spark BoxPARTS LIST MAIN ASSEMBLYPARTS LIST Part #PARTS LIST PARTS LISTPARTS LIST BURNER & LOG ASSEMBLYPARTS LIST Part #WARRANTY The Warranty: Limited LifetimeConditions ExclusionsSee the inside back cover for details