Regency G36D Information for MOBILE/MANUFACTURED Homes After First Sale, To the New Owner

Page 2

To the New Owner:

Congratulations!

You are the owner of a state-of-the-art Gas Fireplace by FIREPLACE PRODUCTS INTERNATIONAL . The G36D is a hand crafted appliance and has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a switch. The model G36D has been approved by Warnock Hersey for both safety and effi ciency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow. Please take a moment now to acquaint yourself with these instructions and the many features of your Regency® Fireplace.

INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE

This UltraGlow® product has been tested and listed by Warnock Hersey as a Direct Vent Wall Furnace to the following standards: VENTED GAS FIREPLACE HEATERS ANSI Z21.88-2002/CSA 2.33-2002 and GAS-FIRED APPLIANCES FOR USE AT HIGH ATLITUDES CAN/CGA 2.17- M91.

This Direct Vent System Appliance must be installed in accordance with the manufacturer's installation instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240-MH Mobile Home Standard in Canada.

This appliance installation must comply with the manufacturer's installation instructions and local codes, if any. In the absence of local codes follow the current National Fuel Gas Code, ANSI Z223.1 and the current National Electrical Code ANSI/NFPA 70 in the U.S.A., and the current CAN/CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22.1 in Canada.

This UltraGlow® Mobile/Manufactured Home Listed appliance comes factory equipped with a means to secure the unit.

This UltraGlow® Mobile/Manufactured Home listed appliance comes equipped with a dedicated #8 ground lug to which an 18 gauge copper wire from the steel chassis ground must be attached.

2

UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace

Image 2
Contents G36D Zero Clearance Direct Vent Gas Fireplace 12/18/05Information for MOBILE/MANUFACTURED Homes After First Sale To the New OwnerTable of Contents 300 Safety LabelCopy of Safety Decal for G36D-NG1 Certified for/Certifiée pour Canada and U.S.AImportant Message Save These Instructions InstallationInstallation Checklist Before YOU StartLocating Your GAS Stove G36D Unit DimensionsDiagram Manufactured Mobile Home Additional RequirementsFraming Finishing ClearancesMantel LEG Clearances Combustible Mantels Venting Introduction Unit Assembly Prior to InstallationTop Standoff Assembly Top Facing Support Side Nailing StripsLocations Area where terminal is not permitedExterior Vent Vertical TerminationVenting Rigid Pipe Venting Components List Secure VentRigid Pipe Venting Systems AlternateRigid Pipe Venting Arrangements Horizontal Terminations UltraGlow Direct Vent System FlexInstallation Rigid Pipe Venting Arrangements Vertical Terminations Installation Description Vertical Termination With CO-LINEAR Flex SystemRequired Parts Flex LinerVenting Arrangements Vertical Terminations Snorkel Terminations Diagram 3aI g h t Achieved Ceiling to the position Firestop spacer must be installedDiagram Roof Pitch Continue to assemble pipe lengthsFor UltraGlow Direct Vent System Flex Installation ProceduresOffset Chart GAS Pipe Pressure Testing Pilot AdjustmentGAS Line Installation High ElevationQty Installation of LPG Conversion KitLPG Conversion Kit Contains DC Sparker Kit Contains QtyGround Wire from Kit Ignitor WireSparker Ignitor Wire Piezo IgnitorChain Install the 1/2 bushing to the heat shieldHeat Shield 02-53 02-51 02-54 LOG SET Installation02-75 02-55 02-52 Rear Grate Tab 5th Grate TabLog indentation Front BracketsInstall fl ush glass as per instructions in manual Place embers in these 3 locations On the burner trayOptional Flush Trim Standard Flush DoorFlush Louvers Thermostat Wire Table Remote ControlWall Switch Wall ThermostatWiring Diagram Do not cut the ground terminal off under any circumstancesOpen the bottom louver door Installing the Optional FANTo Remove the Fan Operating Instructions Normal Operating Sounds of GAS Appliances Maintenance InstructionsCopy of the Lighting Plate Instructions Maintenance Installing Valve Removing ValveG36D Main Assembly Parts List Pilot Assembly GasketG36D Flush Front Assembly UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace Exclusions WarrantyConditions Register your UltraGlow online at