Regency G36D Installation, Important Message Save These Instructions, Before YOU Start

Page 5

INSTALLATION

IMPORTANT MESSAGE

SAVE THESE

INSTRUCTIONS

The G36D-NG 1 or G36D-LP1 Direct Vent Fireplace must be installed in accordance with these instructions. Carefully read all the instructions in this manual fi rst. Consult the "authority having jurisdiction" to determine the need for a permit prior to starting the installation. It is the responsibility of the installer to ensure this fi replace is installed in compliance with manufacturer's instructions and all applicable codes.

BEFORE YOU START

Safe installation and operation of this appliance requires common sense, however, we are required by the Canadian Safety Standards

INSTALLATIONAND REPAIR SHOULD BE DONE BY A QUALIFIED SERVICE PERSON. THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A PROFESSIONAL SERVICE PERSON. MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, BEDDING MATERIAL, ETC. IT IS IMPERATIVE THAT CONTROL COMPARTMENTS, BURNERS AND CIRCULATING AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN.

DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.

WARNING: FAILURE TO INSTALLTHIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AND MAY CAUSE A SERIOUS HOUSE FIRE.

CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES, ESPECIALLYTHEFIREPLACEGLASS, AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION.

YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.

CLOTHING OR OTHER FLAMMABLE MATERIALSHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE.

GENERAL SAFETY INFORMATION

1)The appliance installation must conform with local codes or, in the absence of local codes, with the current Canadian or National Gas Codes, CAN1-B149 or ANSI Z223.1 Installation Codes.

2)The appliance when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes with the current National Electrical Code, ANSI/NFPA 70 or CSA C22.1 Canadian Electrical Code.

3)See general construction and assembly instructions. The appliance and vent should be enclosed.

4)This appliance must be connected to the specifi ed vent and termination cap to the outside of the building envelope. Never vent to another room or inside a building. Make sure that the vent is fi tted as per Venting instructions.

5)Inspect the venting system annually for blockage and any signs of deterioration.

6)Venting terminals shall not be recessed into a wall or siding.

7)Any safety glass removed for servicing must be replaced prior to operating the appliance.

8)To prevent injury, do not allow anyone who is unfamiliar with the operation to use the fi replace.

9)Wearglovesandsafetyglassesforprotection while doing required maintenance.

10)Be aware of electrical wiring locations in walls and ceilings when cutting holes for termination.

11)Under no circumstances should this appliance be modifi ed. Parts that have to be removed for servicing should be replaced prior to operating this appliance.

12)Installation and any repairs to this appliance should be done by a qualifi ed service person. A professional service person should be called to inspect this appliance annually. Make it a practice to have all of your gas appliances checked annually.

13)Do not slam shut or strike the glass door.

14)Under no circumstances should any solid fuels (wood, paper, cardboard, coal, etc.) be used in this appliance.

15)The appliance area must be kept clear and free of combustible materials, (gases and other fl ammable vapours and liquids).

Emissions from burning wood or gas could contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.

INSTALLATION

CHECKLIST

1)Check all clearances to combustibles. Refer to the following sections:

a)Locating Your Gas Stove

b)Clearances

c)Mantel Leg Clearances

d)Combustible Mantels

e)Framing and Finishing

f)Hearth Requirement

2)Assemble Top Standoffs and Top Facing Support and Side Nailing Strips, Refer to the "UnitAseembly Prior to Installation" section. (NOTE: must be done before installing unit into fi replace.)

3)Install vent. Refer to the "Venting" section.

4) Install standard and optional features. Refer to the following sections where applicable:

a. Log Set Installation b. Standard Flush Door

c. Option 1: Remote Control

d. Option 2: Wall Switch

e. Option 3: Wall Thermostat

f. Installating the Optional Fan

9)Final check.

Before leaving this unit with the customer, the installer must ensure that the appliance is

ring correctly and operation fully explained to customer

UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace

5

Image 5
Contents 12/18/05 G36D Zero Clearance Direct Vent Gas FireplaceTo the New Owner Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Copy of Safety Decal for G36D-NG1 Safety Label300 Certified for/Certifiée pour Canada and U.S.AInstallation Checklist InstallationImportant Message Save These Instructions Before YOU StartDiagram G36D Unit DimensionsLocating Your GAS Stove Manufactured Mobile Home Additional RequirementsFraming Finishing ClearancesMantel LEG Clearances Combustible Mantels Top Standoff Assembly Unit Assembly Prior to InstallationVenting Introduction Top Facing Support Side Nailing StripsExterior Vent Area where terminal is not permitedLocations Vertical TerminationVenting Secure Vent Rigid Pipe Venting Components ListAlternate Rigid Pipe Venting SystemsUltraGlow Direct Vent System Flex Rigid Pipe Venting Arrangements Horizontal TerminationsInstallation Rigid Pipe Venting Arrangements Vertical Terminations Installation Required Parts Vertical Termination With CO-LINEAR Flex SystemDescription Flex LinerVenting Arrangements Vertical Terminations Snorkel Terminations Diagram 3aI g h t Achieved Diagram Roof Pitch Firestop spacer must be installedCeiling to the position Continue to assemble pipe lengthsFor UltraGlow Direct Vent System Flex Installation ProceduresOffset Chart GAS Line Installation Pilot AdjustmentGAS Pipe Pressure Testing High ElevationLPG Conversion Kit Contains Installation of LPG Conversion KitQty DC Sparker Kit Contains QtySparker Ignitor Wire Ignitor WireGround Wire from Kit Piezo IgnitorChain Install the 1/2 bushing to the heat shieldHeat Shield 02-53 02-51 02-54 LOG SET Installation02-75 02-55 02-52 Log indentation 5th Grate TabRear Grate Tab Front BracketsPlace embers in these 3 locations On the burner tray Install fl ush glass as per instructions in manualOptional Flush Trim Standard Flush DoorFlush Louvers Wall Switch Remote ControlThermostat Wire Table Wall ThermostatDo not cut the ground terminal off under any circumstances Wiring DiagramOpen the bottom louver door Installing the Optional FANTo Remove the Fan Operating Instructions Normal Operating Sounds of GAS Appliances Maintenance InstructionsCopy of the Lighting Plate Instructions Maintenance Removing Valve Installing ValveG36D Main Assembly Pilot Assembly Gasket Parts ListG36D Flush Front Assembly UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace Exclusions WarrantyConditions Register your UltraGlow online at